Square D Digest 179
Motor Starters and Protectors
TeSys™ Deca GV Manual Starters and Protectors Refer to Catalog MKTED210011EN and 8536CT1901 TeSys™ BV4 Motor Circuit Protection Selection
www.se.com/us
Providing UL508 type D combination ratings in accordance to current NEC installation requirements, the TeSys BV4 motor circuit protector allows for compact motor protection in conjunction with both the TeSys and Square D™ NEMA product families for motor control. The BV4 is a magnetic only, UL489 Listed circuit protector rated up to 100kA short-circuit protect with adjustable instantaneous trip points and can be installed directly to a panel or standard DIN rail. Motor Circuit Protectors must be applied per a listed combination motor controller rating as required by NEC and UL 508A. See UL.com/SCCR for combination ratings or contact local support for a tested combination appendix.
Table 17.92: TeSys™ BV4 Motor Circuit Breaker Selection Frame MCP Ampacity (In)
Protection Level
Adjustable Instantaneous Trip (li)
High Fault Cat. No.
Standard Fault Cat. No.
BV4 17 CONTACTORS AND STARTERS-IEC 2 3.5 7
12-28 21-49 42-98 53-195 110-360 176-650 320-1150 600-1150
BV4T002D BV4T003D BV4T007D BV4T013D BV4T025D BV4T050D BV4T080D BV4T115D
BV4T002J BV4T003J BV4T007J BV4T013J BV4T025J BV4T050J BV4T080J BV4T115J
13 25 50 80
115
TeSys™ Deca GV2 Accessories and Enclosures Table 17.93: Mounting Accessories for GV2 + LC1 D09 to D38 [21]
Mount on Single DIN Rail (Using
Mount on 2 DIN Rails (Using
Mount GV and LC1D Contactor on Independent DIN Rails
Mount GV Directly on Single DIN Rail
Mounting Hardware)
Mounting Hardware)
Electrical Interconnect
GV2AF3
GV1G02
GV2AF4 LAD311
GK2AF01
Mounting Hardware
—
—
Table 17.94: Mounting Accessories for GV2 [21] Description Application
Standard Pack [22]
Catalog Number GV2AF02 GV1F03
Adapter plate
For screw mounting of GV2M
10 10
7.5 mm compensation plate
To allow mounting of GV2M and GV2P on a common busbar
Table 17.95: Bus Bar Accessories for GV2 Description Application
Catalog Number
Pitch
Type E line spacer, for use with or without GV2G busbars Type E line spacer, not for use with or with GV2G busbars Bottom Feed, for use with GV1L3 current limiter
—
GV1G09
Incoming Terminal
—
GV2GH7
— 45 54 72 45 54 45 54 72 54 —
GV2G05 GV2G245 GV2G254 GV2G272 GV2G345 GV2G354 GV2G445 GV2G454 GV2G472 GV2G554
For feeding 2 GV2 starters
For feeding 3 GV2 starters
3-Pole, 63 A Bus Bar
For feeding 4 GV2 starters
For feeding 5 GV2 starters
GV1G10 [23]
Protective Cover
To cover unused bus bar outlets
GV2AF3/G2AF4
[21] Must order in multiples of 10. [22] Orders must specify multiples of quantities listed. [23] Must order in multiples of 5.
17-32
© 2024 Schneider Electric All Rights Reserved
Made with FlippingBook Ebook Creator