Square D Digest 179

TeSys™ Deca GV Manual Starters and Protectors Refer to Catalog MKTED210011EN and 8536CT1901

Motor Starters and Protectors

www.se.com/us

Table 17.96: GV2 Other Accessories Description

Standard Pack [24]

Catalog Number

Application

Increases interrupt capacity when attached to GV2ME or GV2P NEMA 1, 12, Black with trip indication, for use with GV2P NEMA 1, 12, Red/Yellow with trip indication, for use with GV2P NEMA 3R, 4, 4X, Red/Yellow without trip indication, for use with GV2P Operating mechanism support shaft for deep enclosures (≥ 250 mm), for use with GV2P One-piece short shaft for installing operating mechanisms in shallow enclosures, for use with GV2P, GV3P and TeSys Ultra

Current limiter—GV2

1 1 1

GV1L3

GV2APN01 GV2APN02

Through-the-door operating mechanism kits

1

GV2APN04

Angle bracket

1

GVAPK11

Operating mechanism short shaft

1

GVAPA2

Laser tool for installing through-the-door kits

Laser tool

1

GVAPL01

Table 17.97: GV2 Enclosures Description Listing

Max. Side Mounting Aux. Contacts

Catalog Number

Mounting

Enclosure Rating NEMA 1, IP41 NEMA 12/4, IP55 NEMA 1, IP41 NEMA 12/4, IP55 NEMA 1, IP41 NEMA 12/4, IP55

Right Side

LeftSide

1 1 1 1 0 0

1 1 1 1 1 1

GV2MC01 GV2MC02 GV2MP01 GV2MP02 GV2MP03 GV2MP04

Surface mounting

Enclosures for GV2ME with or without accessories

CSA Listed. Not UL Listed.

Flush mounting

Flush mounting, front face reduced

Table 17.98: GV2 Enclosures Accessories Description

Type

Standard Pack [25]

Catalog Number

Padlocking device for GV2M (when padlocked, starter is automatically in Off position) Mushroom head stop push button (40 mm, red) [26]

1

GV2V01

Spring return

1 1 1

GV2K011 GV2K031 GV2K04 GV2E01

Latching

Turn to Release

Latching / Padlockable Turn to Release For enclosures GV2MC01 and GV2MP01

Sealing kit

10

Voltage Trips

Table 17.99: Voltage Trips Only one trip or fault signaling contact can be installed per GV2/GV3 device. Description Characteristics Voltage Frequency

17 CONTACTORS AND STARTERS-IEC

Cat. No. [27]

Undervoltage or Shunt trip (external mounting, 1 block right side only)

110–115V

60Hz

GVA●116

Voltage trips GV2 or GV3P

220–240V

60Hz

GVA●226

GVAU116

Table 17.100: Voltage Trips–Technical Data (GV2AU, GV2AS)

Rated Voltage—660 Vac

Pick-Up Voltage

Drop-Out Voltage

Operating Time [28]

Model GVAU GVAS

Inrush

Sealed

12VA / 8W 14 VA / 10.5 W

3.5 VA / 1.1 W 5VA / 1.6W

0.8—1.1 0.7—1.1

0.35—0.7 0.2—0.75

10—15ms 10—15ms

[24] Orders must specify multiples of quantities listed. [25] Supplied with IP55 sealing kit. [26] Supplied with IP55 sealing kit. [27] To order an undervoltage trip: replace the bullet (●) with a U (for example, GVA U 025). To order a shunt trip: replace the bullet ( ●) with an S (for example, GVAS025 ). [28] From the loss of voltage at the trip terminals to the opening of the starter contacts.