SE Digest 178
TeSys™ D and F Overload Relays
Overload Relay Accessories
Refer to Catalog MKTED210011EN
www.se.com/us
Table 18.64: Power Terminal Protection Shrouds For Use With 2-, 3-, And 4-pole Contactors
Numberof Shrouds PerSet
Catalog Number
LC1F115
6 6 6 6 8 8 8 8
LA9F701 LA9F702 LA9F703 LA9F704 LA9F706 LA9F707 LA9F708
LC1F150, F185
LC1F225, F265, F330, F400 and F4002, F500 and F5002
LC1F630, F6302 and F800
LC1F1154
LC1F1504 and F1854
LC1F2254, F2654, F3304, F4004, F5004
LC1F6304 LA9F709 For contactors LC1F115, LC1F150, and LC1F185, an available touch-safe terminal block may be used in place of lugs for power connections. Table 18.65: Insulated Terminal Blocks For contactor type LC1 For overload relay LR9 Maximum Cable Size Catalog Number F115, F150, F185 F5●57, F5●63, F5●67, F5●69, F57, F63, F67, F69 300MCM LA9F103 TeSys F contactor accessories: page 18-18 TeSys F overload relay accessories: page 18-24 TeSys F replacement coils and parts: page 18-41, page 18-40, and page 18-40 TeSys F dimensions: page 18-45, page 18-54 TeSys D Overload Relay Accessories
LA9F70●
Table 18.66: Mounting Kits and Plates [1] Description
For use with overload relays: LRD01–35 and LR3D01–35
Cat.No. LAD7B10 LAD7B106 LAD7B205 LAD96560
Separate mounting kits for mounting to 35 mm DIN rail or for panel mounting with screws
LRD01–35 and LRD01–35 for ring tongue terminals LRD04L–-32L, LR3D04L–32L, and LR9D01–32
LRD3●●●, LR3D3●●●, LR2D35●●
Table 18.67: Accessories Description Prewiring kit allows direct connection of the N.C. contact of relay LRD01–D32 or LR3D01–D32 to the contactor Remote stop/tripping or electrical reset [2]
Standard Package
Catalog Number LAD7C1 LAD7C2
For use with LC1D09 to D18 LC1D25 to D38
LA7D901
10 10
LAD703 [3] LA7D03 [3] LAD7305
LRD01-D32, LRD3, LR3D01-D32, LR3D3 All relays except LRD01–D32, LR3D01–D31
1 1 1
Reset by flexible cable 500 mm (19.6 in.) LRD01-D32, LRD3, LR3D3
Table 18.68: Control Circuit Voltages for LA7D03 and LAD703 Volts 24
110
AC50/60Hz
B B
F F
DC
LA7D03
18 CONTACTORS AND STARTERS-IEC
[1] When using mounting plates, separate mounting kits are also required. [2] The time that the LA7D03 can remain energized depends on its rest time; 1 s pulse with 9 s rest time; 5 s pulse with 30 s rest time; 10 s pulse with 90 s rest time; maximum pulse duration of 20 s with rest time of 300 s. Consumption on inrush and sealed: < 100 VA [3] Part number to be completed by adding coil voltage code, (for example, LAD703F).
18-23
© 2021 Schneider Electric All Rights Reserved July 30, 2021
Made with FlippingBook flipbook maker