Powering the digital economy EcoStruxure is Schneider Electric’s IoT-enabled, plug-and-play, open, interoperable architecture and platform, in Homes, Buildings, Data Centers, Infrastructure and Industries. EcoStruxure delivers Innovation at Every Level from Connected Products to Edge Control, and Apps, Analytics and Services, on 6 domains of expertise – Power, IT, Building, Machine, Plant and Grid – delivering enhanced value around safety, reliability, operational efficiency, sustainability, and connectivity to our customers..

#WhatsYourBoldIdea

schneider-electric.us/ecostruxure

©2019 Schneider Electric. All Rights Reserved. Schneider Electric I Life Is On and EcoStruxure are trademarks and the property of Schneider Electric SE, its subsidiaries, and affiliated companies. AII other trademarks are the property of their respective owners

Table of Contents Product Section Listing

How to Use Digest 178 Welcome to the Schneider Electric Digest! Over a thousand pages of technical product information to help you specify and select Schneider Electric products. A key element of the Digest 178 is its color-coded Table of Contents, shown at the right, and matching product section tabs throughout the Digest. This colorful approach aids navigation and helps you quickly find the major product categories. A detailed Table of Contents is provided at the beginning of each product section and two indexes are available in the back of the book: an alphabetical listing and an alphanumeric listing. To ensure you have the latest pricing information, list prices are now available online only. This meets our customer and market driven demand to merge technical information with functionality. Finally, the Supplemental and Obsolescence Digest 178 contains additional product information for our international product offer, our legacy products in the obsolescence process, and more. DigestPLUS DigestPLUS provides one location to access the most current Digest updates available in HTML5 and PDF formats, plus many links to additional technical product information to assist with specifying and selecting Schneider Electric products. DigestPLUS is a simple portal into all things Digest related. www.schneider-electric.us/digestplus Field Services for Every Step of the Lifecycle From planning and inception to modernization and end-of-life, Schneider Electric helps you ensure optimal technical and business performance. Our services engineers combine decades of manufacturer-level experience with the latest technology to bring innovation to every level of our offer, and every step of your project. With our IoT-enabled EcoStruxure™ Power solutions, we can help proactively empower facilities with system-health analyses and maintenance service recommendations to optimize performance and help deliver more reliable and efficient power. www.schneider-electric.us/services

1 2 3 4 5 6 7 8 9

Load Centers

Metering Equipment

Safety Switches

Power Monitoring and Control

Protection, Control, and Energy Automation

Surge Protective Devices

Miniature and Molded Case Circuit Breakers Operator Mechanisms and Disconnect Switches

Panelboards

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29

Power Solutions: Integrated

Switchboards and Switchgear

Busway

Wire Management

Transformers

Customer Care Center Have questions or need support?

Medical Products

mySchneider App Download the mySchneider app to find pricing, order status, FAQ’s and Chat on the go. It’s your one stop mobile shop. www.schneider-electric.us/en/work/support/ myschneider-app

NEMA Contactors and Starters

Motor Control Centers

IEC Contactors and Starters

For Distributors Distributors Login to mySE and access all the Schneider Electric Support Tools for the fastest answers. Need more tailored support? Click CHAT under the support tab and an agent will quickly deliver the answer you need. www.myseus.schneider-electric.com/mySchneider Helpful Tools and Calculators Visit our Support Center to view all of our Free Digital Tools and Calculators Schneider Electric is continuously creating and improving our portfolio of free digital calculators and tools designed around the many needs of our customers to help increase efficiency in everything you do. Our tools offer 24/7 access to information to grow your business, are easy to use - on your desktop or mobile device. Get access to tools such as:

Push Buttons and Operator Interface

Electronic Sensors and Machine Cabling

Limit Switches

Pressure, Vacuum, and Float Switches

Relays and Timers

Terminal Blocks

• CAD Drawings • Cross Reference

• Distributor Locator • FAQs

• Partner Portal • ...and much more!

Machine Safeguarding Products

We also offer product selector tools that are designed to assist you through the product selection process with the click of a button. www.schneider-electric.us/en/work/support/

AC Drives and Soft Starts

Automation Products

LayoutFAST: a Revit MEP Plugin that's going to help you select, configure and insert the most updated Schneider Electric product models from the cloud into your design without leaving your Revit project. www.schneider-electric.us/en/partners/resources/layoutfast/

Universal Enclosures

EcoStruxure TM Alphabetical Listing Alpha-Numeric Listing

New and Enhanced Products in Digest 178

www.se.com/us

Section 1 Load Centers QO™ Plug-On Neutral Load Centers with Qwik-Grip .............. 1-11 Homeline™ Plug-On Neutral Load Centers with Qwik-Grip.....1-23 QO™ and Homeline™ Plug-on Neutral SPD...........................1-27 Wiser Energy™ Smart Home...................................................1-41 Section 4 Power Monitoring and Control ION9000 Power and Energy Meters ..........................................4-7 PowerLogic™ EM4900 Series Multi-Circuit Meters .................4-25 Section 5 Protection, Control, and Energy Automation ECOFIT™ 50/51 Protection Relays ...........................................5-4 Sepam™ Protection Relays.......................................................5-5 MiCOM Protection Relays........................................................5-16 SAGE RTUs.............................................................................5-27 Easergy™ T300 Remote Terminal Unit (RTU).........................5-32 Section 6 Surge Protective Devices (SPDs) Surgelogic Type XDSE Surge Protective Devices .....................6-8 Section 7 Miniature and Molded Case Circuit Breakers Masterpact MTZ Circuit Breakers.............................................7-64 Micrologic X Control Units for Masterpact MTZ........................7-65 Masterpact MTZ Accessories...................................................7-67 Section 8 Operating Mechanisms and Disconnect Switches TeSys VLS Disconnect Switches................................................8-9 Section 9 Panelboards Fingersafe IP2X Barriers for NQ Panelboards.........................9-23 Separated Distribution and Split Bus NF and NQ.....................9-35 Section 10 Power Solutions Integrated Equipment Energy Control Center..............................................................10-4 Section 12 Busway H- , J-, and L-Frame Plug-In Units with Electronic Trip and Communication ...................................................................... 12-15 Section 16 NEMA and Definite Purpose Contactors & Starters TeSys N Non-Reversing Contactors.......................................16-14 TeSys N Reversing Contactors...............................................16-15 TeSys N Non-Reversing Starters............................................16-16 TeSys N Reversing Starters ...................................................16-17 TeSys T Motor Management System...................................16-103 TeSys T Controller and Accessories .......................16-104–16-108 Adapted Bimetallic Overload Relay Mounting Bracket Adapter (NEMA Sizes 00–1)..............................................................16-109

Section 21 Limit Switches XCKS Standard Range................................................21-19–21-21 XCKW Wireless and Batteryless Limit Switches....................21-23 Section 22 Pressure, Vacuum, and Float Switches XMEP Pressure Transmitters for Mobile Equipment................22-8 Section 23 Relays and Timers 729 Ice Cube Relays..............................................................23-14 781R Plug-in Relays...............................................................23-16 782 Power Series—DPDT 15 A Relays .................................23-19 783 Series—3PDT 15 A Relays.............................................23-21 784 Series—4PDT 15 A Relays.............................................23-22 750R Series Universal Relays................................................23-24 788R Series Universal Relays................................................23-27 199 Power Relays..................................................................23-48 725 Power Relays..................................................................23-51 389F Power Relays................................................................23-53 300 Power Relays..................................................................23-56 92 Power Relays....................................................................23-58 861H Solid-State Relays.........................................................23-68 6000 Solid-State Relays.........................................................23-79 SSRDIN Solid-State Relays....................................................23-81 861 Solid-State Relays...........................................................23-83 70S2 Solid-State Relays.........................................................23-85 820 Series Time Delay and Sensor Relays..........................23-104 TDR782 Series Time Delay and Sensor Relays...................23-105 TDRPRO Series Time Delay and Sensor Relays.................23-107 Section 25 Machine Safety Products XUSL Light Curtains.................................................................25-5 XCSR Contactless RFiD Safety Sensors.................................25-7 XY2 Cable Pull Switches..........................................................25-8 Section 26 AC Drives and Soft Starters Altivar™ 320 Machine............................................................26-15 Altivar™ 340 Machine............................................................26-17 Altivar™ Process 630/650......................................................26-24 Altivar™ Process 930/950......................................................26-25 Section 27 Automation Products Lexium™ ILx Series Combination Stepper Motors.................27-20 Lexium 28 Series....................................................................27-20 Lexium 32 Series....................................................................27-20 Lexium 32i Series Integrated Servo.......................................27-21 PacDrive 3..............................................................................27-21 Section 29 EcoStruxure™ EcoStruxure™: IoT-enabled Architecture and Platform............29-2

© 2019 Schneider Electric All Rights Reserved

i-1

Table of Contents

Section1 Load Centers

EZ Selector - Selection Assistance

1-2

QO™ Miniature Circuit Breakers

1-3

QO™ Load Centers

1-9

1 LOAD CENTERS

QO™ Miniature Circuit Breakers Breakers

Homeline™ Miniature Circuit Breakers

1-19

Homeline™ Load Centers 1-22 QO/Homeline Load Center Value Packs and Accessories 1-26 QO/Homeline Load Center Dimensions 1-32 Combination Service Entrance Devices 1-35 Homeline Solar Ready PoN CSEDs 1-43 Wiser Energy™ and Wiring Devices 1-44 Enclosed Devices 1-45 Servicepak ™ Power Outlet Panels 1-48

QO™ Load Centers

Homeline™ Miniature Circuit Breakers

Homeline™ Load Centers

Surge Protective Devices (SPD)

Enclosed Devices

CSEDs

Servicepak™ Power Outlet Panels

Wiser Energy™ Smart Home

© 2021 Schneider Electric All Rights Reserved July 30, 2021

1-1

EZ Selector - Selection Assistance

Load Center EZ Selector - Selection Assistance

www.se.com/us

1 LOAD CENTERS

Class 610

QO™ and Homeline™ Load Center EZ Selector - Selection Assistance

EZ Selector Steps to select a load center. 1. Select product type:

• Homeline™ 1 inch format (HOM) • QO™ 3/4 inch format with plug-on neutral (QO) (P) • QO™ 3/4 inch format (QO) 2. Select enclosure type: indoor or outdoor (RB = rainproof) 3. Select single phase (1) or three phase (3) 4. Select type of main: • Main circuit Breaker (M) • Main lugs (L) • Generator panel (GP) 5. Select main ampacity rating 6. Select pole spaces and max. number of 1-pole, single-phase circuits 7. Select cover style: • Surface (box mounted on surface) • Surface (box mounted on surface, hinged cover included) • Flush (box recessed, cover is flush to wall) 8. Value pack (VP) 9. Select ground bar option: • Ground bar factory installed (T) • Ground bar included, field installation (G) 10. Select special application: • Riser panel with gutter • Mfg housing, single phase 3-wire, convertible mains

QO Load Center

• Manufactured housing, single phase, 3-wire • Manufactured housing, single phase, 2-wire

QO™ and Homeline™ Load Centers — Catalog Number Construction

QO

18 16 M100P C

Type

Covers and Construction

QO HOM

= QO = Homeline

= Qwik-Grip = Combination cover included = No cover, order cover separately = Rainproof = Hub ready = Ground bar factory installed = Ground bar included, field installed = Flush cover with door included = Surface cover included = Flush cover included = Feed-thru lugs factory installed

Q C Blank

Phase (only applies to QO)

R B T G

Blank or 1 3

= Single-phase = Three phase

Spaces

DF DS F FT

Maximum number of full-size single-pole circuit breaker spaces.

Circuits 1

NM CU GP WG RBR

= Non-metallic = Copper bus = Generator panel = Wide gutter = Rainproof accepts B-hubs with generator receptacle = Service upgrade ready = Value Pack with standard circuit breakers included = (3) 15 A arc fault circuit breakers included = (1) 15 A arc fault circuit breaker included

Maximum number of single-pole circuits when using tandem circuit breakers. Note: Number of circuits minus number of spaces equals number of tandem circuit breakers accepted.

EP VP AF 1A

Mains Type

M L

= Main circuit breaker = Main lugs

MS MQ DM

= 300 A or 400 A main circuit breaker = Three-phase main circuit breaker = Dual mains

Ampacity Mains rating

Plug-on Neutral

P Blank

= Plug-on Neutral Ready = Does not accept Plug-On Neutral Circuit Breakers

Additional Information • See Circuits [1] . • Search “Load Centers” from our technical FAQs page: www.schneider-electric.us/en/ faqs/home/ • Refer to catalog 1100CT0501.

[1] QO Plug-on neutral load center catalog numbers indicate the number of spaces only. The tables in this document containing QO plug-on neutral load centers list the maximum number of single-pole circuits when using tandem breakers.

1-2

© 2021 Schneider Electric All Rights Reserved July 30, 2021

QO Plug-On Circuit Breakers

QO™ Miniature Circuit Breakers

Class 730, 731, 733 / Refer to Catalog: 0730CT9801

www.se.com/us

QO Standard Plug-On Circuit Breakers Square D brand QO miniature circuit breakers are plug-on products for use in QO load centers, NQOD and NQ panelboards, NQOD and NQ OEM interiors or Speed-D ™ switchboard distribution panels. Bolt-on QOB circuit breakers are for use in NQOD and NQ panelboards or interiors. [1] The Square D exclusive Qwik-Open ™ mechanism, with a trip reaction within 1/60th of a second, is standard on all 1P 15 and 20 A QO circuit breakers.

Table 1.1: Standard QO Plug-On Circuit Breakers Amperes Rating [2] 1P—120/240 Vac 2P—120/240 Vac Common Trip

1 LOAD CENTERS

2P—240Vac [3] Common Trip

3P—240Vac Common Trip

10kAIR

QO110

QO210

QO310

10A 15A 20A 25A 30A 35A 40A 45A 50A 60A 70A 80A 90A

QO115 [4] [5] QO120 [4] [5]

QO215 [4] QO220 [4] QO225 [4] QO230 [4] QO235 [4] QO240 [4] QO245 [4] QO250 [4] QO260 [4] QO270 [4] QO280 [4] QO290 [4] QO2100 [4] QO2110 [4] QO2125 [4]

QO315 [4] QO320 [4] QO325 [4] QO330 [4] QO335 [4] QO340 [4] QO345 [4] QO350 [4] QO360 [4] QO370 [4] QO380 [4] QO390 [4] QO3100 [4]

QO215H QO220H

QO125 [4] QO130 [4] QO135 [4] QO140 [4] QO145 OBS QO150 [4] QO160 [4] QO170 [4]

QO225H OBS

QO230H

QO240H

QO250H OBS QO260H OBS QO270H OBS QO280H OBS QO290H OBS

QO1P 1 Space Required

— — — — — — — —

QO2100H

100A 110A 125A 150A 175A 200A

— — — — —

— — — — —

QO2150 [4] [6] [7] QO2175 [4] [6] [7] QO2200 [4] [6] [7]

QO200

QO300 OBS QO3000 OBS

Molded Case Switch 60 A max.–240 Vac Molded Case Switch 100 A max.–240 Vac

— —

QO2000 OBS

22kAIR [4]

QO115VH [5] QO120VH [5] QO125VH OBS

QO215VH [8] QO220VH [8] QO225VH [8] QO230VH [8] QO240VH [8] QO250VH [8] QO260VH [8] QO270VH [8] QO280VH [8] QO290VH [8]

QO315VH [8] QO320VH [8] QO325VH [8] QO330VH [8] QO340VH [8] QO350VH [8] QO360VH [8] QO370VH [8] QO380VH [8] QO390VH [8] QO3100VH [8]

15A 20A 25A 30A 40A 50A 60A 70A 80A 90A

— — — — — — — — — — — — — — — — — — — — — — — — — — — — — —

QO2P 2 Spaces Required

QO130VH QO140VH QO150VH QO160VH QO170VH

— — — — — — — — — — — — — — — — — —

QO2100VH [8] [9] QO2110VH [8] [9] QO2125VH [8] [9] QO2150VH [6] [8] [7]

100A 110A 125A 150A 175A 200A

— — — — — — — — — — — — — — —

QO2175VH OBS

QO3P 3 Spaces Required

QO2200VH [6] [8] [7]

42kAIR [4]

QOH240 OBS QOH245 OBS QOH250 OBS QOH260 [10]

40A 45A 50A 60A 70A 80A 90A

QOH270 QOH280 QOH290 QOH2100

100A 110A 125A

QOH2110 [10]

QOH2125

65kAIR [4]

QH215 OBS

QH115 OBS QH120 [5] QH125 OBS QH130 OBS

QH315 OBS QH320 OBS QH325 [10] QH330 OBS

15A 20A 25A 30A

QH220

QH225 OBS

QH230

QO2200 2P 200 A 4 Spaces Required

OBS This product is obsolete.

Refer to page 7-2 for Interrupting Ratings, Accessories, and Dimensions.

[1] See Digest Section 1 for load centers, and Section 9 for panelboards and interiors. [2] 10–30 A circuit breakers are suitable for use with 60 o Cor 75 o C conductors. 35–125 A circuit breakers are suitable for use with 75 o C conductors. [3] UL Listed 5 k AIR on corner grounded Delta systems. [4] UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment haing motor group combinations and marked for use with HACR type circuit breakers. [5] UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. [6] Requires four spaces (1 AWG–300 kcmil Al/Cu.) Suitable for switching 120 Vac fluorescent lighting loads. [7] Not suitable for use in 3Ø panels. Use only in 1Ø panel rated 150 A or greater. [8] UL Listed for use ahead of QO, QO-GFI, QO-EPD, QOT, QO-AFI, and QO-PL 10 k AIR circuit breakers to permit their application at 22 kA fault level. [9] 100 A maximum branch mounted opposite. [10] Order only. Contact your local Field Office.

1-3

© 2021 Schneider Electric All Rights Reserved July 30, 2021

QO™ Miniature Circuit Breakers

QO Plug-On Circuit Breakers

Class 730, 731, 733 / Refer to Catalog: 0730CT9801

www.se.com/us

1 LOAD CENTERS

QO/QOB Ring Terminal Table 1.2: QO/QOB Ring Terminal—Factory-Installed Only Ampere Rating Poles

Suffix

1, 2, 3

10–30A 35–60A 35–50A 70–110A 60–100A

5237 5238

1,2

3 2

5273

3 Wire Sizes for QO/QOB Circuit Breakers Table 1.3: Wire Sizes for QO/QOB Circuit Breakers Circuit Breaker Type Ampere Rating [11]

WireSize (AWG/kcmil) 14–8Al/Cu (2) 14–10 Cu 8–2Al/Cu 14–8Al/Cu (2) 14–10 Cu 8–2Al/Cu 4–2/0 Al/Cu 4–300 Al/Cu 8–2Al/Cu 4–2/0 Al/Cu 4–300 Al/Cu

10–30A 10–30A 35–70A 10–30A 10–30A 35–70A 80–125A 150–200A 10–30A 35–70A 80–125A 110–150A

QO 1P

QO 2P

14–8 Al/Cu, (2) 14-10 Cu

QO 3P

QOB-VH

QOT

15–20A 15–30A

12–8 Al 14–8 Cu 12–8 Al 14–8 Cu 12–4 Al 14–6 Cu 12–2 Al 14–2 Cu

QO-AFI, QO-GFI or QO-EPD

40, 50, 60A

QO-PL

10–60A

QOT and QO Tandem Circuit Breakers

QOT tandem circuit breakers have a mounting cam as shown. Installation into a QO load center can only be made in those positions having a mounting pan rail slot. Meets Paragraph 408.54 of the NEC ® . UL Listed as Class CTL. Table 1.4: QOT Tandem Circuit Breakers (CTL)—Not Compatible with Plug-on Neutral Systems Ampere Rating [11] Cat.No. [12] 1P—120/240 Vac 15Aand15A QOT1515 15Aand20A QOT1520 20Aand20A QOT2020 2P—120/240 Vac Common Trip Order two QOT1515 or QOT2020 circuit breakers and handle tie QOTHT for common switching of center two poles. Table 1.5: QO Tandem Circuit Breakers (non-CTL)—Compatible with Plug-on Neutral Systems Ampere Rating [11] Cat.No. [12] 1P—120/240 Vac—1 Space Required 15Aand15A QO1515 15Aand20A QO1520 20Aand20A QO2020 20Aand30A QO2030 30Aand20A QO3020 Two 1P Individual Trip—120/240 Vac—2 Spaces Required 15Aand15A Order two QO1515 or QO2020 circuit breakers and handle tie QOTHT

QOT 1P Tandem 1 Space Required

Rail Bead Mounting Cam

Pan Rail Slot

15Aand20A 20Aand20A 20Aand30A 30Aand20A

QO20303020 [13]

[11] 10–30 A circuit breakers are suitable for use with 60 o Cor 75 o C conductors. 35–125 A circuit breakers are suitable for use with 75 o C conductors. [12] UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment haing motor group combinations and marked for use with HACR type circuit breakers. [13] Includes two circuit breakers (one QO2030 and one QO3020) and handle tie QOTHT.

1-4

© 2021 Schneider Electric All Rights Reserved July 30, 2021

QO Plug-On Circuit Breakers

QO™ Miniature Circuit Breakers

Class 685, 690, 730, 912, 950 / Refer to Catalog: 0730CT9801

www.se.com/us

QO Ground-Fault Circuit Breakers (GFI)

Qwik-Gard ™ circuit breakers provide overload and short circuit protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 mA or more, for people protection. Do not connect to more than 250 feet of load conductor for the total one-way run to prevent nuisance tripping. Table 1.6: QO-GFI Circuit Breakers

Qwik-Gard Circuit Breakers With Ground Fault Circuit Interrupter 1P120Vac 2P Common Trip 120/240 Vac 3PCommon Trip 208Y/120 Vac

1 LOAD CENTERS

Circuit Breaker Type

Ampere Rating [14]

10kAIR 1Space Required QO115GFI QO120GFI

10kAIR 3Spaces Required QO315GFI QO320GFI

1P QO-GFI

2P QO-GFI

22kAIR 1 Space Required

10kAIR 2 Spaces Required

QO115VHGFI QO120VHGFI

QO215GFI QO220GFI QO225GFI QO230GFI QO235GFI QO240GFI QO245GFI QO250GFI

15 20 25 30 35 40 45 50 60 15

Ground-Fault Circuit Interrupter (Pigtail Neutral)

QO330GFI

QO130GFI

QO130VHGFI OBS

— — — — —

— — — — — —

QO340GFI

QO350GFI

QO260GFI [15]

— —

Plug-On Neutral Ground-Fault Circuit Interrupter

QO115PGFI [16]

QO120PGFI [16]

20

OBS This product is obsolete.

QO Arc-Fault Circuit Breaker (QO-CAFI)

QO arc-fault circuit breakers provide protection for Series and Parallel Type Arcing as required by the NEC and local code adoption, and comply with UL1699. Table 1.7: QO-CAFI Circuit Breakers Circuit Breaker Type [17] Ampere Rating One–Pole 120 Vac Two–Pole 120/240 Vac 22kAIR 1 Space Required 10kAIR 2 Space Required 22kAIR 2 Space Required

10kAIR 1Space Required

Combination Arc-fault Interrupter (Pigtail Neutral) Plug-On Neutral Combination Arc-fault Interrupter

QO215CAFI [18] QO220CAFI [18]

QO115CAFI QO120CAFI

QO115VHCAFI QO120VHCAFI

QO215VHCAFI OBS QO220VHCAFI OBS

15 20

1P QO-CAFI Plug-On Neutral

1P QO-CAFI Pigtail

QO115PCAFI QO120PCAFI

QO115VHPCAFI QO120VHPCAFI

15 20

OBS This product is obsolete.

QO Dual Function Circuit Breaker

QO Combination Arc Fault and Ground Fault Circuit Interrupters (Dual Function) provide overload and short circuit protection, plus arc fault and ground fault protection in accordance with the NEC, UL1699 and UL943. Table 1.8: QO-DF Circuit Breakers Circuit Breaker Type [17] Ampere Rating 1P120Vac 10kAIR 1 Space Required 1P120Vac 22kAIR 1 Space Required Combination Arc-fault and Ground Fault Circuit Interrupter (Pigtail Neutral) QO115DF QO120DF QO115VHDF OBS QO120VHDF

15 20 15 20

Plug-On Neutral Combination Arc-fault and Ground Fault Circuit Interrupter

QO115PDF QO120PDF

QO115VHPDF OBS QO120VHPDF

OBS This product is obsolete.

1PQO-DF Pigtail

1PQO-DF Plug-on Neutral

[14] 10–30 A circuit breakers are suitable for use with 60 o Cor 75 o C conductors. 35–60 A circuit breakers are suitable for use with 75 o C conductors. [15] Suitable only for feeding 240 Vac and 208 Vac two-wire loads. Does not contain load neutral connection. [16] New Plug-On Neutral [17] UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment haing motor group combinations and marked for use with HACR type circuit breakers. [18] For 120/240 V only, not for 208Y/120 V.

1-5

© 2021 Schneider Electric All Rights Reserved July 30, 2021

QO™ Miniature Circuit Breakers

QO Plug-On Circuit Breakers

Class 685, 690, 730, 912, 950 / Refer to Catalog: 0730CT9801

www.se.com/us

1 LOAD CENTERS

QO-EPD/EPE Circuit Breakers

QO-EPD/EPE circuit breakers provide overload and short circuit protection combined with Class B ground fault protection. They are designed to provide ground fault protection of equipment at a 30 mA level (EPD) or 100 mA level (EPE). They are not designed to protect people from electrical shock. Table 1.9: QO-EPD Circuit Breakers Ampere Rating [19] 1P 120Vac 10kAIR 1 Space Required 2P Common Trip 120/240 Vac 10kAIR 2 Spaces Required 3P Common Trip 240Vac 10kAIR 3 Spaces Required

QO315EPE [20] QO320EPE [20] QO330EPE [20] QO340EPE [20] QO350EPE [20] —

QO115EPD QO120EPD

QO215EPD QO220EPD QO225EPD QO230EPD QO240EPD QO250EPD

QO315EPD OBS QO320EPD [20] QO330EPD [20] QO340EPD [20] QO350EPD [20] —

15 20 25 30 40 50 60

QO125EPD OBS

QO1P With Shunt Trip

QO130EPD

— — —

QO260EPD [21]

OBS This product is obsolete.

QO Switch Neutral Common Trip Circuit Breakers (QO-SWN)

Switch Neutral Common Trip 2008 NEC ® 514.11 Table 1.10: QO-SWN Circuit Breakers Ampere Rating [22] 2 Wire 120 Vac 10kAIR 2 Spaces Required

3 Wire 120/240 Vac 10kAIR 3 Spaces Required

QO310SWN

QO210SWN OBS

10 15 20 25 30 40 50

QO215SWN QO220SWN

QO315SWN OBS

QO320SWN QO325SWN

QO225SWN OBS QO230SWN OBS QO240SWN OBS QO250SWN OBS

QO330SWN OBS QO340SWN OBS QO350SWN OBS

Two-wire QO-SWN

Three-wire QO-SWN

OBS This product is obsolete.

QO High Intensity Discharge Circuit Breakers (QO-HID) HID circuit breakers are for use on circuits feeding fluorescent and high intensity discharge (HID) lighting systems such as mercury vapor, metal halide, or high pressure sodium. These circuit breakers are physically interchangeable with QO circuit breakers. Table 1.11: QO-HID Circuit Breakers Ampere Rating [22] 1P 120/240 Vac 10kAIR 1 Space Required 2P Common Trip 120/240 Vac 10kAIR 2 Spaces Required 3P Common Trip 240Vac 10kAIR 3 Spaces Required

QO215HID OBS

QO315HID OBS

QO115HID OBS

15 20 25 30 40 50

QO220HID

QO320HID

QO125HID OBS QO130HID OBS QO140HID OBS QO150HID OBS

QO225HID OBS QO230HID OBS QO240HID OBS QO250HID OBS

QO325HID OBS QO330HID OBS

— —

OBS This product is obsolete.

QO Key Operated Circuit Breakers (QO-K)

Key operated QO circuit breakers are available in single-pole construction and can be mounted in any single-pole space which will accept a standard QO circuit breaker. These circuit breakers can be turned ON or OFF or to RESET with a special key (catalog number QOK10) included with the circuit breaker. These circuit breakers are UL Listed

and available as shown in the table. Table 1.12: QO-K Circuit Breakers

120 Vac—10 k AIR (1 Space Required)

Ampere Rating [22]

Ampere Rating [22]

Cat. No.

Cat.No. QO125K

QO110K OBS QO115K OBS QO120K OBS

10 15 20

25 30 —

QO130K OBS

OBS This product is obsolete.

QO-K Key Operated

[19] 10–30 A circuit breakers are suitable for use with 60 o Cor 75 o C conductors. 35–60 A circuit breakers are suitable for use with 75 o C conductors. [20] See note in Instruction Bulletin when using in an enclosure with a QO403 or QON prefix. [21] Suitable only for feeding 240 Vac and 208 Vac two-wire loads. Does not contain load neutral connection. [22] 10–30 A circuit breakers are suitable for use with 60oC or 75oC conductors. 35–60 A circuit breakers are suitable for use with 75oC conductors.

1-6

© 2021 Schneider Electric All Rights Reserved July 30, 2021

QO Plug-On Circuit Breakers

QO™ Miniature Circuit Breakers

Class 685, 690, 730, 912, 950 / Refer to Catalog: 0730CT9801

www.se.com/us

QO High Magnetic Trip Circuit Breakers (QO-HM) High magnetic trip circuit breakers are recommended for applications where high initial inrush may occur and for individual dimmer applications. Table 1.13: QO-HM Circuit Breakers 120 Vac—10 k AIR Ampere Rating [23] 1P 15A QO115HM [24] [25] 20A QO120HM [24] [25] Non-Automatic (Standard) Miniature Switches Miniature non-automatic switches have the same physical packaging as miniature circuit breakers, but open only when the handle is switched to the OFF position. Non-automatic switches provide no overcurrent protection or short circuit protection. They must not be used on systems that have an available fault current greater than the values listed in the table. Non-automatic switches are UL Listed per UL 1087 and are CSA certified. Table 1.14: QO Non-Automatic Miniature Switches, 240 Vac 10 kA Ampere Rating 2P 3P 60 QO200 QO300 100 QO2000 OBS QO3000 OBS This product is obsolete.

1 LOAD CENTERS

[23] 10–30 A circuit breakers are suitable for use with 60oC or 75oC conductors. 35–60 A circuit breakers are suitable for use with 75oC conductors. [24] UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment haing motor group combinations and marked for use with HACR type circuit breakers. [25] UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads.

1-7

© 2021 Schneider Electric All Rights Reserved July 30, 2021

QO™ Miniature Circuit Breakers

QO Accessories

Class 1130 / Refer to Catalog 1100CT0501

www.se.com/us

1 LOAD CENTERS Handle Attachments HandleTie

Accessories for QO/QOB Circuit Breakers

Table 1.15: Accessories for use with QO and QOB Miniature Circuit Breakers Description

Cat. No.

Schedule

QO1HT QOTHT QO3HT QO1LO HLO1 QOHPL QO1PA GFI2PA QO1HPL QO1PL QO1PAF QO2PAF

Converts any two adjacent 120/240 Vac 1P QO circuit breakers to independent trip 2P Converts any two adjacent 120/240 Vac1P side-by-side QOT circuit breakers to independent trip 2P Clamp for holding QO 1P handle in ON or OFF position Clamp for holding QO or Q1 either 1P, 2P or 3P circuit breaker handles in ON or OFF position

DE2E DE2E DE2E DE2E DE2E DE2E DE2E DE2A DE2E DE2E DE2E DE2E DE2E DE2E DE2A DE2A DE2A DE2A DE3 DE2E

Handle Clamp

For padlocking 1P QO circuit breaker in ON or OFF position Looseattachment Fixedattachment For padlocking 1P side-by-side QOT circuit breaker in ON or OFF position

Handle Padlock Attachment for Padlocking in ON or OFF position

QOTHPA OBS

For padlocking 2P QO-GFI circuit breakers in either ON or OFF position, fixed attachment. For 2P and 3P QO and Q1 standard circuit breakers which require padlocking in either ON or OFF position. Looseattachment Fixedattachment

For padlocking 1P QO circuit breaker in OFF position only, fixed attachment. For padlocking 2P and 3P QO circuit breakers in OFF position only, fixed attachment.

Handle Padlock Attachment for Padlocking in OFF position

For padlocking 1P QO-GFI, QO-CAFI, QO-DF and QO-EPD circuit breakers in OFF position only, fixed attachment. For padlocking 2P QO-GFI, QO-CAFI and QO-EPD circuit breakers in OFF position only, fixed attachment.

QOGFI1PAF QOGFI2PAF See Section 7 QO60SL OBS QO2125SL QO2225SL [26] QO3125SL

Ring Terminal

Ring terminals are available as a factory-installed option. 60 A 2P plug-on – 2 spaces required (6–2 Al/Cu) 125 A 2P plug-on – 2 spaces required (12–2/0 Al/Cu) 225 A 2P plug-on – 4 spaces required (4–300 Al/Cu) 125 A 3P plug-on – 3 spaces required (12–2/0 Al/Cu)

Sub-feed Lugs

For interlocking the handles of two 2P or one 2P and one 1P QO and Q1 circuit breakers mounted side-by-side so that only one circuit breaker can be ON at a time (Not QOU) QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed circuit breakers in dual power supply applications. Can be used with (2) 2Ps or (1) 2P and (1) 1P QO circuit breakers in QO816L100 load centers.

Mechanical Interlock Attachment With Retaining Kit

QO2DTI

QO2DTIM

DE2E

OBS This product is obsolete.

QO1PA

QO1PL

QO1HT

HLO1

QO1PAF

QO2DTI

QO1HPL

QOTHPA

QO1LO

QOHPL

QO2PAF

QOGF12PAF

[26] Not suitable for use in 3Ø panels. Use only in 1Ø panel rated 150 A or greater.

1-8

© 2021 Schneider Electric All Rights Reserved July 30, 2021

QO™ Load Centers

QO Indoor Load Centers, 1Ø

Class 736, 1130 / Refer to Catalog 1100CT0501

www.se.com/us

Factory-Installed Accessories for QO and QOB Miniature Circuit Breakers Factory-installed electrical accessories take up an additional pole space on QO, QO GFI, QO-EPD, QO-SWN and QOU circuit breakers. All AC electrical accessories shown below are rated for 50/60 Hz. Accessories are not available for QOB-VH (2P 150 A and 3P 110–150 A) circuit breakers or QO, QOU molded case switches. QO circuit breakers will accept only one accessory per circuit breaker. Undervoltage trip is not available on miniature circuit breakers. Factory-installed accessories are not available for QO-AFI or QO-CAFI Arc Fault Circuit Breakers, QO-CAFI, QO-DF, or QO-PDF circuit breakers, or on QO2150, QO2175, or QO2200 circuit breakers.

1 LOAD CENTERS

Table 1.16: Factory-Installed Accessories for QO/QOB Circuit Breakers Accessory Description Rated Voltage Coil Burden Cat. No. Suffix Accessory

Cat. No. Suffix

Max. Voltage Max.

Contact Comb.

Description

Trips the circuit breaker from a remote location by means of a trip coil energized from a separate circuit. A 120 Vac shunt trip will operate at 55% or more of rated voltage. All other shunt trips will operate at 75% or more of rated voltage. Application • For use with momentary or maintained push button. • Not available on QO-GFI, QO EPD. QO-AFI, QO-CAFI, QO DF, or QO-PDF. • Shunt trip terminals accept (2) 0.14– 0.12 AWG Cu.

Monitors circuit breaker contact status and provides a remote signal indicating the circuit breaker contacts are OPEN or CLOSED. Application • Auxiliary switch terminals accept (2) 14–12 AWG Cu leads. • Leads (EH): Yellow for “A’’, Blue for “B’’, Striped common 18 AWG Cu. Used with control circuits and is actuated only when the circuit breaker has tripped. Standard construction includes a normally-open contact. Application • Leads: Alarm switch terminals accept (2) 14–12 AWG Cu leads.

1A 1B

120Vac 120Vac

5A 5A

-1200 -1201

12Vac/Vdc 24Vac/Vdc

60VA 168 VA -1042

Auxiliary Switches

Shunt Trip

120Vac 208Vac 240Vax

72VA 228VA 288VA

Alarm Switches

-1021

1A 120 Vac 5 A -2100

Plug-on Neutral Load Center Main Lugs, Convertible Mains (1Ø3W—120/240 Vac Indoor—UL Listed) QO Plug-on Neutral Load Centers and CAFI Breakers are engineered for a quick Plug on Neutral connection on every unit. Table 1.17: Convertible Main Lugs Plug-on Neutral Load Center (Compatible with QO Plug-on Circuit Breaker and QO Plug-on Neutral Circuit Breakers)

Load Center Covers

Max. Single Pole Circuits [1]

Max. Tandem Circuit Breakers

Equipment Ground Bar Kit (Factory-Included)

Mains Rating Spaces

BoxNo. [2]

Load Center Box and Interior

Al

CU

Flush/Surface

Mono-Flat

Convertible Mains—Factory-installed Main Circuit Breaker, 65 kA Short Circuit Current Rating—Copper Bus QOM1 Main Frame Size—Convertible to Main Circuit Breaker

QO112L125PG QOC16UF [3] QOC16US QO116L125PG QOC24UF [3] QOC24US QO120L125PG QOC20U100F [3] QOC20U100S QO124L125PG QOC24UF [3] QOC24US QO130L125PG QOC30U125C QO132L125PG QOC32UF [3] QO112L200PG QOC30UF [3] QOC30US QO124L200PG QOC30UF [3] QOC30US QO130L200PG QOC30UF [3] QOC30US QO140L200PG QOC40UF [3] QOC40US QO142L225PG QOC42UF [3] QOC42US QO154L225PG QOC54UF [3]

12

24

12

6–2/0

PKGTALP1

6

16

24

8

6–2/0

PKGTALP1

7

20

24

4

6–2/0

PKGTALP1

6

125A

24 30 32

34 34 38

10

— — —

6–2/0 6–2/0 6–2/0

PK15GTAL PK23GTAL PKGTALP1

7 9 8

4 6

I N D O O R

Convertible Mains—Factory-installed Main Circuit Breaker, 65 kA Short Circuit Current Rating—Copper Bus QOM2 Main Frame Size—Convertible to Main Circuit Breaker

QOCMF30UCW [3] QOCMF30UCW [3] QOCMF30UCW [3] QOCMF42UCW [3] QOCMF54UCW [3] —

4–300

4–250

PKGTALP1

9

12

24

12

4–300

4–250

PKGTALP1

9

24

36

12

200A

4–250

PK23GTAL

9

30

40

10

40

60

20

4–300

4–250

PKGTALP2

10

4–300

PK23GTAL

11

42

52

10

225A

54

64

10

4–300

PK23GTAL

11

Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.

[1] Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. [2] See page 1-32 [3] Available in gray and white. For white equivalencies, add the “W” suffix to the reference, or see page 1-28.

1-9

© 2021 Schneider Electric All Rights Reserved July 30, 2021

QO™ Load Centers

QO Indoor Load Centers, 1Ø

Class 736, 1130 / Refer to Catalog 1100CT0501

www.se.com/us

1 LOAD CENTERS

Field-Installed Main Circuit Breaker Kits, 1Ø

Table 1.18: QOM1 Frame Size—Use with Convertible Main Load Centers Only Main Circuit Breaker Rating [4] Convertible Load Center Mains Rating 22kAIR [5] Lug Wire Size [6] AWG/ kcmil Main Circuit Breaker 50A 100–125 QOM50VH

QOM60VH QOM70VH QOM80VH QOM90VH QOM100VH QOM110VH QOM125VH

60A 70A 80A 90A

100–125 100–125 100–125 100–125 100–125

12–2/0 Al or Cu

QOM1 Frame Size 50–125 Amperes

100A 110A 125A

125 125

Table 1.19: QOM2 Frame Size—Use with Convertible Main Load Centers Only Main Circuit Breaker Rating [4] Convertible Load Center Mains Rating 22kAIR [5] Lug Wire Size [6] AWG/kcmil Main Circuit Breaker [7] 100A 150–225 QOM2100VH

QOM2125VH QOM2150VH QOM2175VH QOM2200VH QOM2225VH

125A 150A 175A 200A 225A

150–225 150–225 200–225 200–225

4–300 Al or Cu

225

QOM2 Frame Size 100–225 Amperes

Plug-on Neutral Load Center Main Breaker, Convertible Mains (1Ø3W—120/240 Vac Indoor—UL Listed) QO Plug-on Neutral Load Centers and CAFI Breakers are engineered for a quick Plug on Neutral connection on every unit. Table 1.20: Convertible Main Breaker Plug-on Neutral Load Centers (Compatible with QO Plug-on Circuit Breakers and QO Plug-on Neutral Circuit Breakers)

Load Center Covers

Equipment Ground Bar Kit (Order Separately)

Max. 1P Circuits

Max. Tandem Breakers

Mains Rating Spaces

BoxNo. [8]

Load Center Box and Interior

Al

Cu

Flush/Surface

Mono-Flat

Convertible Mains — Factory-Installed Main Lugs — 22 kA Short Circuit Current Rating Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (see QO Standard Plug-On Circuit Breakers, page 1-3) [5] , QOM1 Main Circuit Breaker Frame Size—Copper Bus

QOC12UF QOC12US

QO112M100P

12

24

12

6-2/0 6–1

PK9GTA

5

QO116M100P QOC20U100F [9] QOC200U100S QO120M100P QOC20U100F [9] QOC200U100S QO124M100P QOC24UF [9] QOC24US QO132M100P QOC32UF [9] QO124M125P QOC24UF [9] QOC24US QO132M125P QOC32UF [9] QO120M150P QOC30UF [9] QOC30US QO124M150P QOC30UF [9] QOC30US QO130M150P QOC30UF [9] QOC30US QO132M150P QOC40UF [9] QOC40US QO120M200P QOC30UF [9] QOC30US QO124M200P QOC30UF [9] QOC30US QO130M200P QOC30UF [9] QOC30US QO140M200P QOC40UF [9] QOC40US QO142M200P QOC42UF [9] QOC42US QO154M200P QOC54UF [9]

16

24

8

6-2/0 6–1

PK9GTA

6

100A

20

24

4

6-2/0 6–1

PK9GTA

6

24 32 24 32

34 38 34 38

10

— — — —

6-2/0 6-2/0 6-2/0 6-2/0

PK15GTA PK15GTA PK15GTA PK15GTA

7 8 7 8

6

10

125A

6

Convertible Mains — Factory-Installed Main Lugs — 22 kA Short Circuit Current Rating Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (see QO Standard Plug-On Circuit Breakers, page 1-3) [5] , QOM2 Main Circuit Breaker Frame Size—Copper Bus

QOCMF30UCW [9]

4-250

PK15GTA

9

20

30

10

I N D O O R

QOCMF30UCW [9]

4-250

PK15GTA

9

24

36

12

150A

QOCMF30UCW [9]

4-250

PK15GTA

9

30

40

10

32

40

10

4-300 4-250

PK15GTA

10

QOCMF30UCW [9]

20

30

10

4-300 4-250

PK15GTA

9

QOCMF30UCW [9]

24

36

12

4-300 4-250

PK15GTA

9

QO154M200P

QOCMF30UCW [9]

4-250

PK15GTA

9

30

40

10

200A

40

60

20

4-300 4-250

PK23GTA

10

QOCMF42UCW [9] QOCMF54UCW [9]

4-300 4-300 4-300

PK18GTA PK23GTA PK27GTA

11 12 24

42 54 60

52 72 72

10 18 12

QO160M200PC [10]

QO140M225P QOC42UF [9] QOC42US QO142M225P QOC42UF [9] QOC42US

QOCMF42UCW [9]

40

60

20

4-300

PK23GTA

11

225A

QOCMF42UCW [9]

42

52

10

4-300

PK18GTA

11

Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.

Do not exceed the load center mains rating.

[4]

[5] 22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current. [6] Wire range listed for QOM circuit breaker kits is the wire range of that circuit breaker. To find out maximum wire size permitted in a particular load center per UL, see Main Wire Size in that load center table. [7] Add suffix 1021 for 120, 208 or 240 Vac shunt trip. [8] See Indoor Knockout Information and Enclosure Dimensions, page 1-32. [9] Available in gray and white. For white equivalencies, add the “W” suffix to the reference, or see page 1-28. [10] For Certification to IEC 60439-1 contact the local Square D sales office; otherwise panels are NOT CE marked. (For use on 415Y/240 Vac 3-phase 4-wire, 3,000 Short Circuit Current Rating when QOXD...branch circuit breakers are used and 10,000 Short Circuit Current Rating when QO...VS branch circuit breakers are used).

1-10

© 2021 Schneider Electric All Rights Reserved July 30, 2021

QO™ Load Centers

QO Indoor Load Centers, 1Ø

Class 736, 1130 / Refer to Catalog 1100CT0501

www.se.com/us

Field-Installed Main Lugs Kits, 1Ø

Table 1.21: 1Ø Field-Installed Main Lug Kits—Use with Convertible Main Load Centers Only

Useon Convertible Load Center with Mains Rating

Lug Wire Size [12] AWG/kcmil Al orCu

MainLugs Rating [11]

Cat.No.

QOL125 [13]

125A 125A 225A

100–125A 100–125A 150–225A

6–2/0 6–4/0 6–300

QOL125VD [13]

QOL225 [13]

1 LOAD CENTERS

QOL125

QOL225

QO™ Plug-On Neutral Load Centers with Qwik-Grip™ (1Ø3W—120/240 Vac Indoor—UL Listed) The Square D QO plug-on neutral load centers with Qwik-Grip simplify rough-in by eliminating the need to remove knockouts, install wire connectors, and blindly pull wire into the load center. A quick bend of the wire using the wire bend guide on the Qwik-Grip insert and the wire slides into the slot. Once inserted, the Qwik-Grip shield snaps on to keep the wire behind the router for a secure, code-compliant installation.

QO Plug-on Neutral Load Center with Qwik-Grip™

Table 1.22: Plug-on Neutral Load Centers with Qwik-Grip (Compatible with QO Plug-on Circuit Breakers and QO Plug-on Neutral Circuit Breakers) Mains Rating Spaces Max. Single Pole Circuits Max. Tandem Circuit Breakers Load Center Box and Interior Indoor Cover with Door (Order Separately) Main Wire Size AWG/kcmil Equipment Gound Bar Kit Box No. Flush/Surface Mono-Flat Al Cu Convertible Mains—Factory-Installed Main Lugs, 65 kA Short Circuit Current Rating—Copper Bus, QOM1 Main Frame Size, Convertible to Main Circuit Breaker

QOC24UF [14] QOC24US QOC30U125C

PK15GTAL Included PK23GTAL Included PK23GTAL Included PK23GTAL PK23GTAL Included

7Q

QO124L125PQG

24

34

10

125A

6–2/0

QO130L125PQG

9Q

30

34

4

Convertible Mains-Factory—Installed Main Lugs, 65 kA Short Circuit Current Rating—Copper Bus, QOM2 Main Frame Size, Convertible to Main Circuit Breaker 200A 30 40 10 QO130L200PQG QOC30UF [14] QOC30US QOCMF30UCW [14] 6–300

9Q

I N D O O R

QOCMF42UCW [14] QOCMF54UCW [14] QOCMF30UCW [14] QOCMF42UCW [14] QOCMF54UCW [14]

QOC42UF [14] QOC42US QOC54UF [14] QOC30UF [14] QOC30US QOC42UF [14] QOC42US QOC54UF [14]

9Q

QO142L225PQG

42

52

10

225A

54 12Q Convertible Mains—Factory-Installed Main Circuit Breaker, 22 kA Short Circuit Current Rating—Copper Bus, QOM2 Main Frame Size, Convertible to Main Lugs or Main Circuit Breaker 72 18 QO154L225PQG 6–300

PK23GTA (Order separately) PK23GTA (Order separately) PK23GTA (Order separately)

QO130M200PQ

11Q

30

40

10

4–250

QO142M200PQ

11Q

200A

42

52

10

QO154M200PQ

12Q

54

72

18

4–250

[11] Do not exceed the load center mains rating. [12] Wire range listed for QOL lug kits is the wire range of that lug. To find out maximum wire size permitted in a particular load center per UL, see Main Wire Size in that load center table. [13] If main circuit breaker knockout has been removed from the load center’s trim, order appropriate filler plate from Table 1.51, page 1-24 [14] Available in gray and white. For white equivalencies, add the “W” suffix to the reference, or see page 1-28.

1-11

© 2021 Schneider Electric All Rights Reserved July 30, 2021

QO™ Load Centers

QO Load Centers, Rainproof, 1Ø Class 1130 / Refer to Catalog 1100CT0501

www.se.com/us

1 LOAD CENTERS Mains Rating

QO Load Centers with Included Cover (1Ø3W—120/240 Vac Indoor—UL Listed) Table 1.23: Load Centers with Included Cover (Compatible with QO Plug-on Circuit Breakers and QO Plug-on Neutral Circuit Breakers)

Short Circuit Current Rating

Max. 1P Circuits [15]

Max. Tandem Circuit Breakers

Load Center [16] Box, Interior, and Cover

BoxNo. [17]

Equipment Ground Bar Kit

Spaces

Al

Cu

PKGTALP1 Included PKGTALP1 Included

QO112L125PGC

65kA

12

24

12

6-2/0

1

QO120L125PGC

125A

65kA

20

24

4

6-2/0

1

PK15GTA, LK100AN Included

QO124L125PGC

65kA

24

34

10

6-2/0

2

Convertible Mains—Factory-Installed Main Lugs [18] —QOM2 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-3)—Copper Bus 200A 65kA 30 40 10 QO130L200PGC 4-250

PK23GTA, LK100AN Included PK23GTA, LK100AN Included PK23GTA, LK100AN Included

9

QO142L225PGC

65kA

42

52

10

4-300

11

225A

QO154L225PGC

65kA

54

72

18

4-300

12

Convertible Mains—Factory-Installed Main Circuit Breaker— QOM1 Main Frame Size—Convertible to Main Lugs (See page 1-24 or Lower Amperage Main Circuit Breaker (See page 1-3)—Copper Bus [8][19]

QO112M100PC QO116M100PC QO120M100PC QO124M100PC

6–2/0 6–2/0 6–2/0

6–1 6–1 6–1

PK9GTA PK9GTA PK9GTA PK15GTA PK15GTA PK18GTA PK15GTA PK23GTA PK18GTA PK23GTA

5 6 6 7

22kA 22kA 22kA 22kA

12 16 20 24

24 24 24 34

12

8 4

100A

4-300

10

Convertible Mains—Factory-Installed Main Circuit Breaker— QOM2 Main Frame Size—Convertible to Main Lugs (See page 1-24 or Lower Amperage Main Circuit Breaker (See page 1-3)—Copper Bus [8][19] 150A 22kA 30 40 10 QO130M150PC 4-250

9

QO142M150PC QO130M200PC QO140M200PC QO142M200PC QO154M200PC

4-300 4-250 4-300 4-300

11

22kA 22kA 22kA 22kA 22kA

42 30 40 42 54

52 40 60 52 72

10 10 20 10 18

9

4-300

4-250

10 11

200A

12 Plug–on Neutral Load Center Main Lugs, Convertible Mains (1Ø3W—120/240 Vac Rainproof—UL Listed) QO Plug-on Neutral Load Centers and CAFI Breakers are engineered for a quick Plug on Neutral connection on every unit. Table 1.24: Convertible Main Lugs Plug-on Neutral Load Center (Compatible with QO Plug-on Circuit Breakers and QO Plug-on Neutral Circuit Breakers) Mains Rating Spaces Max. Load Center Box and Interior Al Cu Equipment Ground Bar Kit (Factory Included) BoxNo. [20] Single Pole Circuits [15]

Max. Tandem Circuit Breakers

Convertible Mains — Factory-Installed Main Lugs — 65 kA Short Circuit Current Rating [21][18][22] QOM1 Main Circuit Breaker Frame Size, Convertible to Main Circuit Breaker — Equipment Ground Bar Included

R A I N P R O O F

QO112L125PGRB QO116L125PGRB QO124L125PGRB

12 16 24

24 24 34

12

6–2/0 6–2/0 6–2/0

PKGTALP1 PKGTALP1 PK15GTA

3R 4R 4R

125A

8

10

Convertible Mains — Factory-Installed Main Lugs — 65 kA Short Circuit Current Rating [21][18][22] QOM2 Main Circuit Breaker Frame Size, Convertible to Main Circuit Breaker — Equipment Ground Bar Included

QO112L200PGRB QO130L200PGRB QO140L200PGRB QO142L225PGRB

4–300

4–250

PKGTALP1 PK23GTAL PKGTALP2

5R 6R 7R 8R

12 30 40 42

24 40 60 52

12 10 20 10

200A

4–250

4–300

4–250

PK23GTA, LK100AN

225A

4–300

Above listings through 200 A mains rating meet Federal Specification W-P-115C as Type 1, Class 2.

[15] Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. [16] Order F for flush device or S for surface device. [17] See page 1-32 [18] UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only. [19] [9] 22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current. [20] See Table 1.76 Enclosure Dimensions, page 1-34 or Indoor Enclosure Dimensions and Knockout Information, page 1-32 [21] UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed. [22] Side hinge door device; allow 1-1/4 in. on left side for door to open.

1-12

© 2021 Schneider Electric All Rights Reserved July 30, 2021