Powering the digital economy EcoStruxure is Schneider Electric’s IoT-enabled, plug-and-play, open, interoperable architecture and platform, in Homes, Buildings, Data Centers, Infrastructure and Industries. EcoStruxure delivers Innovation at Every Level from Connected Products to Edge Control, and Apps, Analytics and Services, on 6 domains of expertise – Power, IT, Building, Machine, Plant and Grid – delivering enhanced value around safety, reliability, operational efficiency, sustainability, and connectivity to our customers..
#WhatsYourBoldIdea
schneider-electric.us/ecostruxure
©2019 Schneider Electric. All Rights Reserved. Schneider Electric I Life Is On and EcoStruxure are trademarks and the property of Schneider Electric SE, its subsidiaries, and affiliated companies. AII other trademarks are the property of their respective owners
Table of Contents Product Section Listing
How to Use Digest 178 Welcome to the Schneider Electric Digest! Over a thousand pages of technical product information to help you specify and select Schneider Electric products. A key element of the Digest 178 is its color-coded Table of Contents, shown at the right, and matching product section tabs throughout the Digest. This colorful approach aids navigation and helps you quickly find the major product categories. A detailed Table of Contents is provided at the beginning of each product section and two indexes are available in the back of the book: an alphabetical listing and an alphanumeric listing. To ensure you have the latest pricing information, list prices are now available online only. This meets our customer and market driven demand to merge technical information with functionality. Finally, the Supplemental and Obsolescence Digest 178 contains additional product information for our international product offer, our legacy products in the obsolescence process, and more. DigestPLUS DigestPLUS provides one location to access the most current Digest updates available in HTML5 and PDF formats, plus many links to additional technical product information to assist with specifying and selecting Schneider Electric products. DigestPLUS is a simple portal into all things Digest related. www.schneider-electric.us/digestplus Field Services for Every Step of the Lifecycle From planning and inception to modernization and end-of-life, Schneider Electric helps you ensure optimal technical and business performance. Our services engineers combine decades of manufacturer-level experience with the latest technology to bring innovation to every level of our offer, and every step of your project. With our IoT-enabled EcoStruxure™ Power solutions, we can help proactively empower facilities with system-health analyses and maintenance service recommendations to optimize performance and help deliver more reliable and efficient power. www.schneider-electric.us/services
1 2 3 4 5 6 7 8 9
Load Centers
Metering Equipment
Safety Switches
Power Monitoring and Control
Protection, Control, and Energy Automation
Surge Protective Devices
Miniature and Molded Case Circuit Breakers Operator Mechanisms and Disconnect Switches
Panelboards
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29
Power Solutions: Integrated
Switchboards and Switchgear
Busway
Wire Management
Transformers
Customer Care Center Have questions or need support?
Medical Products
mySchneider App Download the mySchneider app to find pricing, order status, FAQ’s and Chat on the go. It’s your one stop mobile shop. www.schneider-electric.us/en/work/support/ myschneider-app
NEMA Contactors and Starters
Motor Control Centers
IEC Contactors and Starters
For Distributors Distributors Login to mySE and access all the Schneider Electric Support Tools for the fastest answers. Need more tailored support? Click CHAT under the support tab and an agent will quickly deliver the answer you need. www.myseus.schneider-electric.com/mySchneider Helpful Tools and Calculators Visit our Support Center to view all of our Free Digital Tools and Calculators Schneider Electric is continuously creating and improving our portfolio of free digital calculators and tools designed around the many needs of our customers to help increase efficiency in everything you do. Our tools offer 24/7 access to information to grow your business, are easy to use - on your desktop or mobile device. Get access to tools such as:
Push Buttons and Operator Interface
Electronic Sensors and Machine Cabling
Limit Switches
Pressure, Vacuum, and Float Switches
Relays and Timers
Terminal Blocks
• CAD Drawings • Cross Reference
• Distributor Locator • FAQs
• Partner Portal • ...and much more!
Machine Safeguarding Products
We also offer product selector tools that are designed to assist you through the product selection process with the click of a button. www.schneider-electric.us/en/work/support/
AC Drives and Soft Starts
Automation Products
LayoutFAST: a Revit MEP Plugin that's going to help you select, configure and insert the most updated Schneider Electric product models from the cloud into your design without leaving your Revit project. www.schneider-electric.us/en/partners/resources/layoutfast/
Universal Enclosures
EcoStruxure TM Alphabetical Listing Alpha-Numeric Listing
New and Enhanced Products in Digest 178
www.se.com/us
Section 1 Load Centers QO™ Plug-On Neutral Load Centers with Qwik-Grip .............. 1-11 Homeline™ Plug-On Neutral Load Centers with Qwik-Grip.....1-23 QO™ and Homeline™ Plug-on Neutral SPD...........................1-27 Wiser Energy™ Smart Home...................................................1-41 Section 4 Power Monitoring and Control ION9000 Power and Energy Meters ..........................................4-7 PowerLogic™ EM4900 Series Multi-Circuit Meters .................4-25 Section 5 Protection, Control, and Energy Automation ECOFIT™ 50/51 Protection Relays ...........................................5-4 Sepam™ Protection Relays.......................................................5-5 MiCOM Protection Relays........................................................5-16 SAGE RTUs.............................................................................5-27 Easergy™ T300 Remote Terminal Unit (RTU).........................5-32 Section 6 Surge Protective Devices (SPDs) Surgelogic Type XDSE Surge Protective Devices .....................6-8 Section 7 Miniature and Molded Case Circuit Breakers Masterpact MTZ Circuit Breakers.............................................7-64 Micrologic X Control Units for Masterpact MTZ........................7-65 Masterpact MTZ Accessories...................................................7-67 Section 8 Operating Mechanisms and Disconnect Switches TeSys VLS Disconnect Switches................................................8-9 Section 9 Panelboards Fingersafe IP2X Barriers for NQ Panelboards.........................9-23 Separated Distribution and Split Bus NF and NQ.....................9-35 Section 10 Power Solutions Integrated Equipment Energy Control Center..............................................................10-4 Section 12 Busway H- , J-, and L-Frame Plug-In Units with Electronic Trip and Communication ...................................................................... 12-15 Section 16 NEMA and Definite Purpose Contactors & Starters TeSys N Non-Reversing Contactors.......................................16-14 TeSys N Reversing Contactors...............................................16-15 TeSys N Non-Reversing Starters............................................16-16 TeSys N Reversing Starters ...................................................16-17 TeSys T Motor Management System...................................16-103 TeSys T Controller and Accessories .......................16-104–16-108 Adapted Bimetallic Overload Relay Mounting Bracket Adapter (NEMA Sizes 00–1)..............................................................16-109
Section 21 Limit Switches XCKS Standard Range................................................21-19–21-21 XCKW Wireless and Batteryless Limit Switches....................21-23 Section 22 Pressure, Vacuum, and Float Switches XMEP Pressure Transmitters for Mobile Equipment................22-8 Section 23 Relays and Timers 729 Ice Cube Relays..............................................................23-14 781R Plug-in Relays...............................................................23-16 782 Power Series—DPDT 15 A Relays .................................23-19 783 Series—3PDT 15 A Relays.............................................23-21 784 Series—4PDT 15 A Relays.............................................23-22 750R Series Universal Relays................................................23-24 788R Series Universal Relays................................................23-27 199 Power Relays..................................................................23-48 725 Power Relays..................................................................23-51 389F Power Relays................................................................23-53 300 Power Relays..................................................................23-56 92 Power Relays....................................................................23-58 861H Solid-State Relays.........................................................23-68 6000 Solid-State Relays.........................................................23-79 SSRDIN Solid-State Relays....................................................23-81 861 Solid-State Relays...........................................................23-83 70S2 Solid-State Relays.........................................................23-85 820 Series Time Delay and Sensor Relays..........................23-104 TDR782 Series Time Delay and Sensor Relays...................23-105 TDRPRO Series Time Delay and Sensor Relays.................23-107 Section 25 Machine Safety Products XUSL Light Curtains.................................................................25-5 XCSR Contactless RFiD Safety Sensors.................................25-7 XY2 Cable Pull Switches..........................................................25-8 Section 26 AC Drives and Soft Starters Altivar™ 320 Machine............................................................26-15 Altivar™ 340 Machine............................................................26-17 Altivar™ Process 630/650......................................................26-24 Altivar™ Process 930/950......................................................26-25 Section 27 Automation Products Lexium™ ILx Series Combination Stepper Motors.................27-20 Lexium 28 Series....................................................................27-20 Lexium 32 Series....................................................................27-20 Lexium 32i Series Integrated Servo.......................................27-21 PacDrive 3..............................................................................27-21 Section 29 EcoStruxure™ EcoStruxure™: IoT-enabled Architecture and Platform............29-2
© 2019 Schneider Electric All Rights Reserved
i-1
Table of Contents
Section1 Load Centers
EZ Selector - Selection Assistance
1-2
QO™ Miniature Circuit Breakers
1-3
QO™ Load Centers
1-9
1 LOAD CENTERS
QO™ Miniature Circuit Breakers Breakers
Homeline™ Miniature Circuit Breakers
1-19
Homeline™ Load Centers 1-22 QO/Homeline Load Center Value Packs and Accessories 1-26 QO/Homeline Load Center Dimensions 1-32 Combination Service Entrance Devices 1-35 Homeline Solar Ready PoN CSEDs 1-43 Wiser Energy™ and Wiring Devices 1-44 Enclosed Devices 1-45 Servicepak ™ Power Outlet Panels 1-48
QO™ Load Centers
Homeline™ Miniature Circuit Breakers
Homeline™ Load Centers
Surge Protective Devices (SPD)
Enclosed Devices
CSEDs
Servicepak™ Power Outlet Panels
Wiser Energy™ Smart Home
© 2021 Schneider Electric All Rights Reserved July 30, 2021
1-1
EZ Selector - Selection Assistance
Load Center EZ Selector - Selection Assistance
www.se.com/us
1 LOAD CENTERS
Class 610
QO™ and Homeline™ Load Center EZ Selector - Selection Assistance
EZ Selector Steps to select a load center. 1. Select product type:
• Homeline™ 1 inch format (HOM) • QO™ 3/4 inch format with plug-on neutral (QO) (P) • QO™ 3/4 inch format (QO) 2. Select enclosure type: indoor or outdoor (RB = rainproof) 3. Select single phase (1) or three phase (3) 4. Select type of main: • Main circuit Breaker (M) • Main lugs (L) • Generator panel (GP) 5. Select main ampacity rating 6. Select pole spaces and max. number of 1-pole, single-phase circuits 7. Select cover style: • Surface (box mounted on surface) • Surface (box mounted on surface, hinged cover included) • Flush (box recessed, cover is flush to wall) 8. Value pack (VP) 9. Select ground bar option: • Ground bar factory installed (T) • Ground bar included, field installation (G) 10. Select special application: • Riser panel with gutter • Mfg housing, single phase 3-wire, convertible mains
QO Load Center
• Manufactured housing, single phase, 3-wire • Manufactured housing, single phase, 2-wire
QO™ and Homeline™ Load Centers — Catalog Number Construction
QO
18 16 M100P C
Type
Covers and Construction
QO HOM
= QO = Homeline
= Qwik-Grip = Combination cover included = No cover, order cover separately = Rainproof = Hub ready = Ground bar factory installed = Ground bar included, field installed = Flush cover with door included = Surface cover included = Flush cover included = Feed-thru lugs factory installed
Q C Blank
Phase (only applies to QO)
R B T G
Blank or 1 3
= Single-phase = Three phase
Spaces
DF DS F FT
Maximum number of full-size single-pole circuit breaker spaces.
Circuits 1
NM CU GP WG RBR
= Non-metallic = Copper bus = Generator panel = Wide gutter = Rainproof accepts B-hubs with generator receptacle = Service upgrade ready = Value Pack with standard circuit breakers included = (3) 15 A arc fault circuit breakers included = (1) 15 A arc fault circuit breaker included
Maximum number of single-pole circuits when using tandem circuit breakers. Note: Number of circuits minus number of spaces equals number of tandem circuit breakers accepted.
EP VP AF 1A
Mains Type
M L
= Main circuit breaker = Main lugs
MS MQ DM
= 300 A or 400 A main circuit breaker = Three-phase main circuit breaker = Dual mains
Ampacity Mains rating
Plug-on Neutral
P Blank
= Plug-on Neutral Ready = Does not accept Plug-On Neutral Circuit Breakers
Additional Information • See Circuits [1] . • Search “Load Centers” from our technical FAQs page: www.schneider-electric.us/en/ faqs/home/ • Refer to catalog 1100CT0501.
[1] QO Plug-on neutral load center catalog numbers indicate the number of spaces only. The tables in this document containing QO plug-on neutral load centers list the maximum number of single-pole circuits when using tandem breakers.
1-2
© 2021 Schneider Electric All Rights Reserved July 30, 2021
QO Plug-On Circuit Breakers
QO™ Miniature Circuit Breakers
Class 730, 731, 733 / Refer to Catalog: 0730CT9801
www.se.com/us
QO Standard Plug-On Circuit Breakers Square D brand QO miniature circuit breakers are plug-on products for use in QO load centers, NQOD and NQ panelboards, NQOD and NQ OEM interiors or Speed-D ™ switchboard distribution panels. Bolt-on QOB circuit breakers are for use in NQOD and NQ panelboards or interiors. [1] The Square D exclusive Qwik-Open ™ mechanism, with a trip reaction within 1/60th of a second, is standard on all 1P 15 and 20 A QO circuit breakers.
Table 1.1: Standard QO Plug-On Circuit Breakers Amperes Rating [2] 1P—120/240 Vac 2P—120/240 Vac Common Trip
1 LOAD CENTERS
2P—240Vac [3] Common Trip
3P—240Vac Common Trip
10kAIR
QO110
QO210
QO310
10A 15A 20A 25A 30A 35A 40A 45A 50A 60A 70A 80A 90A
—
QO115 [4] [5] QO120 [4] [5]
QO215 [4] QO220 [4] QO225 [4] QO230 [4] QO235 [4] QO240 [4] QO245 [4] QO250 [4] QO260 [4] QO270 [4] QO280 [4] QO290 [4] QO2100 [4] QO2110 [4] QO2125 [4]
QO315 [4] QO320 [4] QO325 [4] QO330 [4] QO335 [4] QO340 [4] QO345 [4] QO350 [4] QO360 [4] QO370 [4] QO380 [4] QO390 [4] QO3100 [4]
QO215H QO220H
QO125 [4] QO130 [4] QO135 [4] QO140 [4] QO145 OBS QO150 [4] QO160 [4] QO170 [4]
QO225H OBS
QO230H
—
QO240H
—
QO250H OBS QO260H OBS QO270H OBS QO280H OBS QO290H OBS
QO1P 1 Space Required
— — — — — — — —
QO2100H
100A 110A 125A 150A 175A 200A
— — — — —
— — — — —
QO2150 [4] [6] [7] QO2175 [4] [6] [7] QO2200 [4] [6] [7]
QO200
QO300 OBS QO3000 OBS
Molded Case Switch 60 A max.–240 Vac Molded Case Switch 100 A max.–240 Vac
— —
QO2000 OBS
22kAIR [4]
QO115VH [5] QO120VH [5] QO125VH OBS
QO215VH [8] QO220VH [8] QO225VH [8] QO230VH [8] QO240VH [8] QO250VH [8] QO260VH [8] QO270VH [8] QO280VH [8] QO290VH [8]
QO315VH [8] QO320VH [8] QO325VH [8] QO330VH [8] QO340VH [8] QO350VH [8] QO360VH [8] QO370VH [8] QO380VH [8] QO390VH [8] QO3100VH [8]
15A 20A 25A 30A 40A 50A 60A 70A 80A 90A
— — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
QO2P 2 Spaces Required
QO130VH QO140VH QO150VH QO160VH QO170VH
— — — — — — — — — — — — — — — — — —
QO2100VH [8] [9] QO2110VH [8] [9] QO2125VH [8] [9] QO2150VH [6] [8] [7]
100A 110A 125A 150A 175A 200A
— — — — — — — — — — — — — — —
QO2175VH OBS
QO3P 3 Spaces Required
QO2200VH [6] [8] [7]
42kAIR [4]
QOH240 OBS QOH245 OBS QOH250 OBS QOH260 [10]
40A 45A 50A 60A 70A 80A 90A
QOH270 QOH280 QOH290 QOH2100
100A 110A 125A
QOH2110 [10]
QOH2125
65kAIR [4]
QH215 OBS
QH115 OBS QH120 [5] QH125 OBS QH130 OBS
QH315 OBS QH320 OBS QH325 [10] QH330 OBS
15A 20A 25A 30A
QH220
QH225 OBS
QH230
QO2200 2P 200 A 4 Spaces Required
OBS This product is obsolete.
Refer to page 7-2 for Interrupting Ratings, Accessories, and Dimensions.
[1] See Digest Section 1 for load centers, and Section 9 for panelboards and interiors. [2] 10–30 A circuit breakers are suitable for use with 60 o Cor 75 o C conductors. 35–125 A circuit breakers are suitable for use with 75 o C conductors. [3] UL Listed 5 k AIR on corner grounded Delta systems. [4] UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment haing motor group combinations and marked for use with HACR type circuit breakers. [5] UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. [6] Requires four spaces (1 AWG–300 kcmil Al/Cu.) Suitable for switching 120 Vac fluorescent lighting loads. [7] Not suitable for use in 3Ø panels. Use only in 1Ø panel rated 150 A or greater. [8] UL Listed for use ahead of QO, QO-GFI, QO-EPD, QOT, QO-AFI, and QO-PL 10 k AIR circuit breakers to permit their application at 22 kA fault level. [9] 100 A maximum branch mounted opposite. [10] Order only. Contact your local Field Office.
1-3
© 2021 Schneider Electric All Rights Reserved July 30, 2021
QO™ Miniature Circuit Breakers
QO Plug-On Circuit Breakers
Class 730, 731, 733 / Refer to Catalog: 0730CT9801
www.se.com/us
1 LOAD CENTERS
QO/QOB Ring Terminal Table 1.2: QO/QOB Ring Terminal—Factory-Installed Only Ampere Rating Poles
Suffix
1, 2, 3
10–30A 35–60A 35–50A 70–110A 60–100A
5237 5238
1,2
3 2
5273
3 Wire Sizes for QO/QOB Circuit Breakers Table 1.3: Wire Sizes for QO/QOB Circuit Breakers Circuit Breaker Type Ampere Rating [11]
WireSize (AWG/kcmil) 14–8Al/Cu (2) 14–10 Cu 8–2Al/Cu 14–8Al/Cu (2) 14–10 Cu 8–2Al/Cu 4–2/0 Al/Cu 4–300 Al/Cu 8–2Al/Cu 4–2/0 Al/Cu 4–300 Al/Cu
10–30A 10–30A 35–70A 10–30A 10–30A 35–70A 80–125A 150–200A 10–30A 35–70A 80–125A 110–150A
QO 1P
QO 2P
14–8 Al/Cu, (2) 14-10 Cu
QO 3P
QOB-VH
QOT
15–20A 15–30A
12–8 Al 14–8 Cu 12–8 Al 14–8 Cu 12–4 Al 14–6 Cu 12–2 Al 14–2 Cu
QO-AFI, QO-GFI or QO-EPD
40, 50, 60A
QO-PL
10–60A
QOT and QO Tandem Circuit Breakers
QOT tandem circuit breakers have a mounting cam as shown. Installation into a QO load center can only be made in those positions having a mounting pan rail slot. Meets Paragraph 408.54 of the NEC ® . UL Listed as Class CTL. Table 1.4: QOT Tandem Circuit Breakers (CTL)—Not Compatible with Plug-on Neutral Systems Ampere Rating [11] Cat.No. [12] 1P—120/240 Vac 15Aand15A QOT1515 15Aand20A QOT1520 20Aand20A QOT2020 2P—120/240 Vac Common Trip Order two QOT1515 or QOT2020 circuit breakers and handle tie QOTHT for common switching of center two poles. Table 1.5: QO Tandem Circuit Breakers (non-CTL)—Compatible with Plug-on Neutral Systems Ampere Rating [11] Cat.No. [12] 1P—120/240 Vac—1 Space Required 15Aand15A QO1515 15Aand20A QO1520 20Aand20A QO2020 20Aand30A QO2030 30Aand20A QO3020 Two 1P Individual Trip—120/240 Vac—2 Spaces Required 15Aand15A Order two QO1515 or QO2020 circuit breakers and handle tie QOTHT
QOT 1P Tandem 1 Space Required
Rail Bead Mounting Cam
Pan Rail Slot
15Aand20A 20Aand20A 20Aand30A 30Aand20A
—
QO20303020 [13]
—
[11] 10–30 A circuit breakers are suitable for use with 60 o Cor 75 o C conductors. 35–125 A circuit breakers are suitable for use with 75 o C conductors. [12] UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment haing motor group combinations and marked for use with HACR type circuit breakers. [13] Includes two circuit breakers (one QO2030 and one QO3020) and handle tie QOTHT.
1-4
© 2021 Schneider Electric All Rights Reserved July 30, 2021
QO Plug-On Circuit Breakers
QO™ Miniature Circuit Breakers
Class 685, 690, 730, 912, 950 / Refer to Catalog: 0730CT9801
www.se.com/us
QO Ground-Fault Circuit Breakers (GFI)
Qwik-Gard ™ circuit breakers provide overload and short circuit protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 mA or more, for people protection. Do not connect to more than 250 feet of load conductor for the total one-way run to prevent nuisance tripping. Table 1.6: QO-GFI Circuit Breakers
Qwik-Gard Circuit Breakers With Ground Fault Circuit Interrupter 1P120Vac 2P Common Trip 120/240 Vac 3PCommon Trip 208Y/120 Vac
1 LOAD CENTERS
Circuit Breaker Type
Ampere Rating [14]
10kAIR 1Space Required QO115GFI QO120GFI
10kAIR 3Spaces Required QO315GFI QO320GFI
1P QO-GFI
2P QO-GFI
22kAIR 1 Space Required
10kAIR 2 Spaces Required
QO115VHGFI QO120VHGFI
QO215GFI QO220GFI QO225GFI QO230GFI QO235GFI QO240GFI QO245GFI QO250GFI
15 20 25 30 35 40 45 50 60 15
—
—
—
Ground-Fault Circuit Interrupter (Pigtail Neutral)
QO330GFI
QO130GFI
QO130VHGFI OBS
— — — — —
— — — — — —
—
QO340GFI
—
QO350GFI
QO260GFI [15]
— —
Plug-On Neutral Ground-Fault Circuit Interrupter
QO115PGFI [16]
—
QO120PGFI [16]
20
—
—
—
OBS This product is obsolete.
QO Arc-Fault Circuit Breaker (QO-CAFI)
QO arc-fault circuit breakers provide protection for Series and Parallel Type Arcing as required by the NEC and local code adoption, and comply with UL1699. Table 1.7: QO-CAFI Circuit Breakers Circuit Breaker Type [17] Ampere Rating One–Pole 120 Vac Two–Pole 120/240 Vac 22kAIR 1 Space Required 10kAIR 2 Space Required 22kAIR 2 Space Required
10kAIR 1Space Required
Combination Arc-fault Interrupter (Pigtail Neutral) Plug-On Neutral Combination Arc-fault Interrupter
QO215CAFI [18] QO220CAFI [18]
QO115CAFI QO120CAFI
QO115VHCAFI QO120VHCAFI
QO215VHCAFI OBS QO220VHCAFI OBS
15 20
1P QO-CAFI Plug-On Neutral
1P QO-CAFI Pigtail
QO115PCAFI QO120PCAFI
QO115VHPCAFI QO120VHPCAFI
15 20
—
—
OBS This product is obsolete.
QO Dual Function Circuit Breaker
QO Combination Arc Fault and Ground Fault Circuit Interrupters (Dual Function) provide overload and short circuit protection, plus arc fault and ground fault protection in accordance with the NEC, UL1699 and UL943. Table 1.8: QO-DF Circuit Breakers Circuit Breaker Type [17] Ampere Rating 1P120Vac 10kAIR 1 Space Required 1P120Vac 22kAIR 1 Space Required Combination Arc-fault and Ground Fault Circuit Interrupter (Pigtail Neutral) QO115DF QO120DF QO115VHDF OBS QO120VHDF
15 20 15 20
Plug-On Neutral Combination Arc-fault and Ground Fault Circuit Interrupter
QO115PDF QO120PDF
QO115VHPDF OBS QO120VHPDF
OBS This product is obsolete.
1PQO-DF Pigtail
1PQO-DF Plug-on Neutral
[14] 10–30 A circuit breakers are suitable for use with 60 o Cor 75 o C conductors. 35–60 A circuit breakers are suitable for use with 75 o C conductors. [15] Suitable only for feeding 240 Vac and 208 Vac two-wire loads. Does not contain load neutral connection. [16] New Plug-On Neutral [17] UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment haing motor group combinations and marked for use with HACR type circuit breakers. [18] For 120/240 V only, not for 208Y/120 V.
1-5
© 2021 Schneider Electric All Rights Reserved July 30, 2021
QO™ Miniature Circuit Breakers
QO Plug-On Circuit Breakers
Class 685, 690, 730, 912, 950 / Refer to Catalog: 0730CT9801
www.se.com/us
1 LOAD CENTERS
QO-EPD/EPE Circuit Breakers
QO-EPD/EPE circuit breakers provide overload and short circuit protection combined with Class B ground fault protection. They are designed to provide ground fault protection of equipment at a 30 mA level (EPD) or 100 mA level (EPE). They are not designed to protect people from electrical shock. Table 1.9: QO-EPD Circuit Breakers Ampere Rating [19] 1P 120Vac 10kAIR 1 Space Required 2P Common Trip 120/240 Vac 10kAIR 2 Spaces Required 3P Common Trip 240Vac 10kAIR 3 Spaces Required
QO315EPE [20] QO320EPE [20] QO330EPE [20] QO340EPE [20] QO350EPE [20] —
QO115EPD QO120EPD
QO215EPD QO220EPD QO225EPD QO230EPD QO240EPD QO250EPD
QO315EPD OBS QO320EPD [20] QO330EPD [20] QO340EPD [20] QO350EPD [20] —
15 20 25 30 40 50 60
QO125EPD OBS
QO1P With Shunt Trip
QO130EPD
— — —
QO260EPD [21]
—
—
OBS This product is obsolete.
QO Switch Neutral Common Trip Circuit Breakers (QO-SWN)
Switch Neutral Common Trip 2008 NEC ® 514.11 Table 1.10: QO-SWN Circuit Breakers Ampere Rating [22] 2 Wire 120 Vac 10kAIR 2 Spaces Required
3 Wire 120/240 Vac 10kAIR 3 Spaces Required
QO310SWN
QO210SWN OBS
10 15 20 25 30 40 50
QO215SWN QO220SWN
QO315SWN OBS
QO320SWN QO325SWN
QO225SWN OBS QO230SWN OBS QO240SWN OBS QO250SWN OBS
QO330SWN OBS QO340SWN OBS QO350SWN OBS
Two-wire QO-SWN
Three-wire QO-SWN
OBS This product is obsolete.
QO High Intensity Discharge Circuit Breakers (QO-HID) HID circuit breakers are for use on circuits feeding fluorescent and high intensity discharge (HID) lighting systems such as mercury vapor, metal halide, or high pressure sodium. These circuit breakers are physically interchangeable with QO circuit breakers. Table 1.11: QO-HID Circuit Breakers Ampere Rating [22] 1P 120/240 Vac 10kAIR 1 Space Required 2P Common Trip 120/240 Vac 10kAIR 2 Spaces Required 3P Common Trip 240Vac 10kAIR 3 Spaces Required
QO215HID OBS
QO315HID OBS
QO115HID OBS
15 20 25 30 40 50
QO220HID
QO320HID
—
QO125HID OBS QO130HID OBS QO140HID OBS QO150HID OBS
QO225HID OBS QO230HID OBS QO240HID OBS QO250HID OBS
QO325HID OBS QO330HID OBS
— —
OBS This product is obsolete.
QO Key Operated Circuit Breakers (QO-K)
Key operated QO circuit breakers are available in single-pole construction and can be mounted in any single-pole space which will accept a standard QO circuit breaker. These circuit breakers can be turned ON or OFF or to RESET with a special key (catalog number QOK10) included with the circuit breaker. These circuit breakers are UL Listed
and available as shown in the table. Table 1.12: QO-K Circuit Breakers
120 Vac—10 k AIR (1 Space Required)
Ampere Rating [22]
Ampere Rating [22]
Cat. No.
Cat.No. QO125K
QO110K OBS QO115K OBS QO120K OBS
10 15 20
25 30 —
QO130K OBS
—
OBS This product is obsolete.
QO-K Key Operated
[19] 10–30 A circuit breakers are suitable for use with 60 o Cor 75 o C conductors. 35–60 A circuit breakers are suitable for use with 75 o C conductors. [20] See note in Instruction Bulletin when using in an enclosure with a QO403 or QON prefix. [21] Suitable only for feeding 240 Vac and 208 Vac two-wire loads. Does not contain load neutral connection. [22] 10–30 A circuit breakers are suitable for use with 60oC or 75oC conductors. 35–60 A circuit breakers are suitable for use with 75oC conductors.
1-6
© 2021 Schneider Electric All Rights Reserved July 30, 2021
QO Plug-On Circuit Breakers
QO™ Miniature Circuit Breakers
Class 685, 690, 730, 912, 950 / Refer to Catalog: 0730CT9801
www.se.com/us
QO High Magnetic Trip Circuit Breakers (QO-HM) High magnetic trip circuit breakers are recommended for applications where high initial inrush may occur and for individual dimmer applications. Table 1.13: QO-HM Circuit Breakers 120 Vac—10 k AIR Ampere Rating [23] 1P 15A QO115HM [24] [25] 20A QO120HM [24] [25] Non-Automatic (Standard) Miniature Switches Miniature non-automatic switches have the same physical packaging as miniature circuit breakers, but open only when the handle is switched to the OFF position. Non-automatic switches provide no overcurrent protection or short circuit protection. They must not be used on systems that have an available fault current greater than the values listed in the table. Non-automatic switches are UL Listed per UL 1087 and are CSA certified. Table 1.14: QO Non-Automatic Miniature Switches, 240 Vac 10 kA Ampere Rating 2P 3P 60 QO200 QO300 100 QO2000 OBS QO3000 OBS This product is obsolete.
1 LOAD CENTERS
[23] 10–30 A circuit breakers are suitable for use with 60oC or 75oC conductors. 35–60 A circuit breakers are suitable for use with 75oC conductors. [24] UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment haing motor group combinations and marked for use with HACR type circuit breakers. [25] UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads.
1-7
© 2021 Schneider Electric All Rights Reserved July 30, 2021
QO™ Miniature Circuit Breakers
QO Accessories
Class 1130 / Refer to Catalog 1100CT0501
www.se.com/us
1 LOAD CENTERS Handle Attachments HandleTie
Accessories for QO/QOB Circuit Breakers
Table 1.15: Accessories for use with QO and QOB Miniature Circuit Breakers Description
Cat. No.
Schedule
QO1HT QOTHT QO3HT QO1LO HLO1 QOHPL QO1PA GFI2PA QO1HPL QO1PL QO1PAF QO2PAF
Converts any two adjacent 120/240 Vac 1P QO circuit breakers to independent trip 2P Converts any two adjacent 120/240 Vac1P side-by-side QOT circuit breakers to independent trip 2P Clamp for holding QO 1P handle in ON or OFF position Clamp for holding QO or Q1 either 1P, 2P or 3P circuit breaker handles in ON or OFF position
DE2E DE2E DE2E DE2E DE2E DE2E DE2E DE2A DE2E DE2E DE2E DE2E DE2E DE2E DE2A DE2A DE2A DE2A DE3 DE2E
Handle Clamp
For padlocking 1P QO circuit breaker in ON or OFF position Looseattachment Fixedattachment For padlocking 1P side-by-side QOT circuit breaker in ON or OFF position
Handle Padlock Attachment for Padlocking in ON or OFF position
QOTHPA OBS
For padlocking 2P QO-GFI circuit breakers in either ON or OFF position, fixed attachment. For 2P and 3P QO and Q1 standard circuit breakers which require padlocking in either ON or OFF position. Looseattachment Fixedattachment
For padlocking 1P QO circuit breaker in OFF position only, fixed attachment. For padlocking 2P and 3P QO circuit breakers in OFF position only, fixed attachment.
Handle Padlock Attachment for Padlocking in OFF position
For padlocking 1P QO-GFI, QO-CAFI, QO-DF and QO-EPD circuit breakers in OFF position only, fixed attachment. For padlocking 2P QO-GFI, QO-CAFI and QO-EPD circuit breakers in OFF position only, fixed attachment.
QOGFI1PAF QOGFI2PAF See Section 7 QO60SL OBS QO2125SL QO2225SL [26] QO3125SL
Ring Terminal
Ring terminals are available as a factory-installed option. 60 A 2P plug-on – 2 spaces required (6–2 Al/Cu) 125 A 2P plug-on – 2 spaces required (12–2/0 Al/Cu) 225 A 2P plug-on – 4 spaces required (4–300 Al/Cu) 125 A 3P plug-on – 3 spaces required (12–2/0 Al/Cu)
Sub-feed Lugs
For interlocking the handles of two 2P or one 2P and one 1P QO and Q1 circuit breakers mounted side-by-side so that only one circuit breaker can be ON at a time (Not QOU) QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed circuit breakers in dual power supply applications. Can be used with (2) 2Ps or (1) 2P and (1) 1P QO circuit breakers in QO816L100 load centers.
Mechanical Interlock Attachment With Retaining Kit
QO2DTI
QO2DTIM
DE2E
OBS This product is obsolete.
QO1PA
QO1PL
QO1HT
HLO1
QO1PAF
QO2DTI
QO1HPL
QOTHPA
QO1LO
QOHPL
QO2PAF
QOGF12PAF
[26] Not suitable for use in 3Ø panels. Use only in 1Ø panel rated 150 A or greater.
1-8
© 2021 Schneider Electric All Rights Reserved July 30, 2021
QO™ Load Centers
QO Indoor Load Centers, 1Ø
Class 736, 1130 / Refer to Catalog 1100CT0501
www.se.com/us
Factory-Installed Accessories for QO and QOB Miniature Circuit Breakers Factory-installed electrical accessories take up an additional pole space on QO, QO GFI, QO-EPD, QO-SWN and QOU circuit breakers. All AC electrical accessories shown below are rated for 50/60 Hz. Accessories are not available for QOB-VH (2P 150 A and 3P 110–150 A) circuit breakers or QO, QOU molded case switches. QO circuit breakers will accept only one accessory per circuit breaker. Undervoltage trip is not available on miniature circuit breakers. Factory-installed accessories are not available for QO-AFI or QO-CAFI Arc Fault Circuit Breakers, QO-CAFI, QO-DF, or QO-PDF circuit breakers, or on QO2150, QO2175, or QO2200 circuit breakers.
1 LOAD CENTERS
Table 1.16: Factory-Installed Accessories for QO/QOB Circuit Breakers Accessory Description Rated Voltage Coil Burden Cat. No. Suffix Accessory
Cat. No. Suffix
Max. Voltage Max.
Contact Comb.
Description
Trips the circuit breaker from a remote location by means of a trip coil energized from a separate circuit. A 120 Vac shunt trip will operate at 55% or more of rated voltage. All other shunt trips will operate at 75% or more of rated voltage. Application • For use with momentary or maintained push button. • Not available on QO-GFI, QO EPD. QO-AFI, QO-CAFI, QO DF, or QO-PDF. • Shunt trip terminals accept (2) 0.14– 0.12 AWG Cu.
Monitors circuit breaker contact status and provides a remote signal indicating the circuit breaker contacts are OPEN or CLOSED. Application • Auxiliary switch terminals accept (2) 14–12 AWG Cu leads. • Leads (EH): Yellow for “A’’, Blue for “B’’, Striped common 18 AWG Cu. Used with control circuits and is actuated only when the circuit breaker has tripped. Standard construction includes a normally-open contact. Application • Leads: Alarm switch terminals accept (2) 14–12 AWG Cu leads.
1A 1B
120Vac 120Vac
5A 5A
-1200 -1201
12Vac/Vdc 24Vac/Vdc
60VA 168 VA -1042
Auxiliary Switches
Shunt Trip
120Vac 208Vac 240Vax
72VA 228VA 288VA
Alarm Switches
-1021
1A 120 Vac 5 A -2100
Plug-on Neutral Load Center Main Lugs, Convertible Mains (1Ø3W—120/240 Vac Indoor—UL Listed) QO Plug-on Neutral Load Centers and CAFI Breakers are engineered for a quick Plug on Neutral connection on every unit. Table 1.17: Convertible Main Lugs Plug-on Neutral Load Center (Compatible with QO Plug-on Circuit Breaker and QO Plug-on Neutral Circuit Breakers)
Load Center Covers
Max. Single Pole Circuits [1]
Max. Tandem Circuit Breakers
Equipment Ground Bar Kit (Factory-Included)
Mains Rating Spaces
BoxNo. [2]
Load Center Box and Interior
Al
CU
Flush/Surface
Mono-Flat
Convertible Mains—Factory-installed Main Circuit Breaker, 65 kA Short Circuit Current Rating—Copper Bus QOM1 Main Frame Size—Convertible to Main Circuit Breaker
QO112L125PG QOC16UF [3] QOC16US QO116L125PG QOC24UF [3] QOC24US QO120L125PG QOC20U100F [3] QOC20U100S QO124L125PG QOC24UF [3] QOC24US QO130L125PG QOC30U125C QO132L125PG QOC32UF [3] QO112L200PG QOC30UF [3] QOC30US QO124L200PG QOC30UF [3] QOC30US QO130L200PG QOC30UF [3] QOC30US QO140L200PG QOC40UF [3] QOC40US QO142L225PG QOC42UF [3] QOC42US QO154L225PG QOC54UF [3]
12
24
12
—
6–2/0
PKGTALP1
6
16
24
8
—
6–2/0
PKGTALP1
7
20
24
4
—
6–2/0
PKGTALP1
6
125A
24 30 32
34 34 38
10
— — —
6–2/0 6–2/0 6–2/0
PK15GTAL PK23GTAL PKGTALP1
7 9 8
4 6
I N D O O R
Convertible Mains—Factory-installed Main Circuit Breaker, 65 kA Short Circuit Current Rating—Copper Bus QOM2 Main Frame Size—Convertible to Main Circuit Breaker
QOCMF30UCW [3] QOCMF30UCW [3] QOCMF30UCW [3] QOCMF42UCW [3] QOCMF54UCW [3] —
4–300
4–250
PKGTALP1
9
12
24
12
4–300
4–250
PKGTALP1
9
24
36
12
200A
4–250
PK23GTAL
9
30
40
10
40
60
20
4–300
4–250
PKGTALP2
10
4–300
PK23GTAL
11
42
52
10
225A
54
64
10
4–300
PK23GTAL
11
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
[1] Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. [2] See page 1-32 [3] Available in gray and white. For white equivalencies, add the “W” suffix to the reference, or see page 1-28.
1-9
© 2021 Schneider Electric All Rights Reserved July 30, 2021
QO™ Load Centers
QO Indoor Load Centers, 1Ø
Class 736, 1130 / Refer to Catalog 1100CT0501
www.se.com/us
1 LOAD CENTERS
Field-Installed Main Circuit Breaker Kits, 1Ø
Table 1.18: QOM1 Frame Size—Use with Convertible Main Load Centers Only Main Circuit Breaker Rating [4] Convertible Load Center Mains Rating 22kAIR [5] Lug Wire Size [6] AWG/ kcmil Main Circuit Breaker 50A 100–125 QOM50VH
QOM60VH QOM70VH QOM80VH QOM90VH QOM100VH QOM110VH QOM125VH
60A 70A 80A 90A
100–125 100–125 100–125 100–125 100–125
12–2/0 Al or Cu
QOM1 Frame Size 50–125 Amperes
100A 110A 125A
125 125
Table 1.19: QOM2 Frame Size—Use with Convertible Main Load Centers Only Main Circuit Breaker Rating [4] Convertible Load Center Mains Rating 22kAIR [5] Lug Wire Size [6] AWG/kcmil Main Circuit Breaker [7] 100A 150–225 QOM2100VH
QOM2125VH QOM2150VH QOM2175VH QOM2200VH QOM2225VH
125A 150A 175A 200A 225A
150–225 150–225 200–225 200–225
4–300 Al or Cu
225
QOM2 Frame Size 100–225 Amperes
Plug-on Neutral Load Center Main Breaker, Convertible Mains (1Ø3W—120/240 Vac Indoor—UL Listed) QO Plug-on Neutral Load Centers and CAFI Breakers are engineered for a quick Plug on Neutral connection on every unit. Table 1.20: Convertible Main Breaker Plug-on Neutral Load Centers (Compatible with QO Plug-on Circuit Breakers and QO Plug-on Neutral Circuit Breakers)
Load Center Covers
Equipment Ground Bar Kit (Order Separately)
Max. 1P Circuits
Max. Tandem Breakers
Mains Rating Spaces
BoxNo. [8]
Load Center Box and Interior
Al
Cu
Flush/Surface
Mono-Flat
Convertible Mains — Factory-Installed Main Lugs — 22 kA Short Circuit Current Rating Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (see QO Standard Plug-On Circuit Breakers, page 1-3) [5] , QOM1 Main Circuit Breaker Frame Size—Copper Bus
QOC12UF QOC12US
QO112M100P
12
24
12
—
6-2/0 6–1
PK9GTA
5
QO116M100P QOC20U100F [9] QOC200U100S QO120M100P QOC20U100F [9] QOC200U100S QO124M100P QOC24UF [9] QOC24US QO132M100P QOC32UF [9] QO124M125P QOC24UF [9] QOC24US QO132M125P QOC32UF [9] QO120M150P QOC30UF [9] QOC30US QO124M150P QOC30UF [9] QOC30US QO130M150P QOC30UF [9] QOC30US QO132M150P QOC40UF [9] QOC40US QO120M200P QOC30UF [9] QOC30US QO124M200P QOC30UF [9] QOC30US QO130M200P QOC30UF [9] QOC30US QO140M200P QOC40UF [9] QOC40US QO142M200P QOC42UF [9] QOC42US QO154M200P QOC54UF [9]
16
24
8
—
6-2/0 6–1
PK9GTA
6
100A
20
24
4
—
6-2/0 6–1
PK9GTA
6
24 32 24 32
34 38 34 38
10
— — — —
6-2/0 6-2/0 6-2/0 6-2/0
PK15GTA PK15GTA PK15GTA PK15GTA
7 8 7 8
6
10
125A
6
Convertible Mains — Factory-Installed Main Lugs — 22 kA Short Circuit Current Rating Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (see QO Standard Plug-On Circuit Breakers, page 1-3) [5] , QOM2 Main Circuit Breaker Frame Size—Copper Bus
QOCMF30UCW [9]
4-250
PK15GTA
9
20
30
10
I N D O O R
QOCMF30UCW [9]
4-250
PK15GTA
9
24
36
12
150A
QOCMF30UCW [9]
4-250
PK15GTA
9
30
40
10
32
40
10
—
4-300 4-250
PK15GTA
10
QOCMF30UCW [9]
20
30
10
4-300 4-250
PK15GTA
9
QOCMF30UCW [9]
24
36
12
4-300 4-250
PK15GTA
9
QO154M200P
QOCMF30UCW [9]
4-250
PK15GTA
9
30
40
10
200A
40
60
20
—
4-300 4-250
PK23GTA
10
QOCMF42UCW [9] QOCMF54UCW [9]
4-300 4-300 4-300
PK18GTA PK23GTA PK27GTA
11 12 24
42 54 60
52 72 72
10 18 12
QO160M200PC [10]
—
—
QO140M225P QOC42UF [9] QOC42US QO142M225P QOC42UF [9] QOC42US
QOCMF42UCW [9]
40
60
20
4-300
PK23GTA
11
225A
QOCMF42UCW [9]
42
52
10
4-300
PK18GTA
11
Above listings through 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
Do not exceed the load center mains rating.
[4]
[5] 22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current. [6] Wire range listed for QOM circuit breaker kits is the wire range of that circuit breaker. To find out maximum wire size permitted in a particular load center per UL, see Main Wire Size in that load center table. [7] Add suffix 1021 for 120, 208 or 240 Vac shunt trip. [8] See Indoor Knockout Information and Enclosure Dimensions, page 1-32. [9] Available in gray and white. For white equivalencies, add the “W” suffix to the reference, or see page 1-28. [10] For Certification to IEC 60439-1 contact the local Square D sales office; otherwise panels are NOT CE marked. (For use on 415Y/240 Vac 3-phase 4-wire, 3,000 Short Circuit Current Rating when QOXD...branch circuit breakers are used and 10,000 Short Circuit Current Rating when QO...VS branch circuit breakers are used).
1-10
© 2021 Schneider Electric All Rights Reserved July 30, 2021
QO™ Load Centers
QO Indoor Load Centers, 1Ø
Class 736, 1130 / Refer to Catalog 1100CT0501
www.se.com/us
Field-Installed Main Lugs Kits, 1Ø
Table 1.21: 1Ø Field-Installed Main Lug Kits—Use with Convertible Main Load Centers Only
Useon Convertible Load Center with Mains Rating
Lug Wire Size [12] AWG/kcmil Al orCu
MainLugs Rating [11]
Cat.No.
QOL125 [13]
125A 125A 225A
100–125A 100–125A 150–225A
6–2/0 6–4/0 6–300
QOL125VD [13]
QOL225 [13]
1 LOAD CENTERS
QOL125
QOL225
QO™ Plug-On Neutral Load Centers with Qwik-Grip™ (1Ø3W—120/240 Vac Indoor—UL Listed) The Square D QO plug-on neutral load centers with Qwik-Grip simplify rough-in by eliminating the need to remove knockouts, install wire connectors, and blindly pull wire into the load center. A quick bend of the wire using the wire bend guide on the Qwik-Grip insert and the wire slides into the slot. Once inserted, the Qwik-Grip shield snaps on to keep the wire behind the router for a secure, code-compliant installation.
QO Plug-on Neutral Load Center with Qwik-Grip™
Table 1.22: Plug-on Neutral Load Centers with Qwik-Grip (Compatible with QO Plug-on Circuit Breakers and QO Plug-on Neutral Circuit Breakers) Mains Rating Spaces Max. Single Pole Circuits Max. Tandem Circuit Breakers Load Center Box and Interior Indoor Cover with Door (Order Separately) Main Wire Size AWG/kcmil Equipment Gound Bar Kit Box No. Flush/Surface Mono-Flat Al Cu Convertible Mains—Factory-Installed Main Lugs, 65 kA Short Circuit Current Rating—Copper Bus, QOM1 Main Frame Size, Convertible to Main Circuit Breaker
QOC24UF [14] QOC24US QOC30U125C
PK15GTAL Included PK23GTAL Included PK23GTAL Included PK23GTAL PK23GTAL Included
7Q
QO124L125PQG
24
34
10
—
125A
6–2/0
QO130L125PQG
9Q
30
34
4
—
Convertible Mains-Factory—Installed Main Lugs, 65 kA Short Circuit Current Rating—Copper Bus, QOM2 Main Frame Size, Convertible to Main Circuit Breaker 200A 30 40 10 QO130L200PQG QOC30UF [14] QOC30US QOCMF30UCW [14] 6–300
9Q
I N D O O R
QOCMF42UCW [14] QOCMF54UCW [14] QOCMF30UCW [14] QOCMF42UCW [14] QOCMF54UCW [14]
QOC42UF [14] QOC42US QOC54UF [14] QOC30UF [14] QOC30US QOC42UF [14] QOC42US QOC54UF [14]
9Q
QO142L225PQG
42
52
10
225A
54 12Q Convertible Mains—Factory-Installed Main Circuit Breaker, 22 kA Short Circuit Current Rating—Copper Bus, QOM2 Main Frame Size, Convertible to Main Lugs or Main Circuit Breaker 72 18 QO154L225PQG 6–300
PK23GTA (Order separately) PK23GTA (Order separately) PK23GTA (Order separately)
QO130M200PQ
11Q
30
40
10
4–250
QO142M200PQ
11Q
200A
42
52
10
QO154M200PQ
12Q
54
72
18
4–250
[11] Do not exceed the load center mains rating. [12] Wire range listed for QOL lug kits is the wire range of that lug. To find out maximum wire size permitted in a particular load center per UL, see Main Wire Size in that load center table. [13] If main circuit breaker knockout has been removed from the load center’s trim, order appropriate filler plate from Table 1.51, page 1-24 [14] Available in gray and white. For white equivalencies, add the “W” suffix to the reference, or see page 1-28.
1-11
© 2021 Schneider Electric All Rights Reserved July 30, 2021
QO™ Load Centers
QO Load Centers, Rainproof, 1Ø Class 1130 / Refer to Catalog 1100CT0501
www.se.com/us
1 LOAD CENTERS Mains Rating
QO Load Centers with Included Cover (1Ø3W—120/240 Vac Indoor—UL Listed) Table 1.23: Load Centers with Included Cover (Compatible with QO Plug-on Circuit Breakers and QO Plug-on Neutral Circuit Breakers)
Short Circuit Current Rating
Max. 1P Circuits [15]
Max. Tandem Circuit Breakers
Load Center [16] Box, Interior, and Cover
BoxNo. [17]
Equipment Ground Bar Kit
Spaces
Al
Cu
PKGTALP1 Included PKGTALP1 Included
QO112L125PGC
65kA
12
24
12
6-2/0
1
QO120L125PGC
125A
65kA
20
24
4
6-2/0
1
PK15GTA, LK100AN Included
QO124L125PGC
65kA
24
34
10
6-2/0
2
Convertible Mains—Factory-Installed Main Lugs [18] —QOM2 Main Frame Size—Convertible to Main Circuit Breaker (See page 1-3)—Copper Bus 200A 65kA 30 40 10 QO130L200PGC 4-250
PK23GTA, LK100AN Included PK23GTA, LK100AN Included PK23GTA, LK100AN Included
9
QO142L225PGC
65kA
42
52
10
4-300
11
225A
QO154L225PGC
65kA
54
72
18
4-300
12
Convertible Mains—Factory-Installed Main Circuit Breaker— QOM1 Main Frame Size—Convertible to Main Lugs (See page 1-24 or Lower Amperage Main Circuit Breaker (See page 1-3)—Copper Bus [8][19]
QO112M100PC QO116M100PC QO120M100PC QO124M100PC
6–2/0 6–2/0 6–2/0
6–1 6–1 6–1
PK9GTA PK9GTA PK9GTA PK15GTA PK15GTA PK18GTA PK15GTA PK23GTA PK18GTA PK23GTA
5 6 6 7
22kA 22kA 22kA 22kA
12 16 20 24
24 24 24 34
12
8 4
100A
4-300
10
Convertible Mains—Factory-Installed Main Circuit Breaker— QOM2 Main Frame Size—Convertible to Main Lugs (See page 1-24 or Lower Amperage Main Circuit Breaker (See page 1-3)—Copper Bus [8][19] 150A 22kA 30 40 10 QO130M150PC 4-250
9
QO142M150PC QO130M200PC QO140M200PC QO142M200PC QO154M200PC
4-300 4-250 4-300 4-300
11
22kA 22kA 22kA 22kA 22kA
42 30 40 42 54
52 40 60 52 72
10 10 20 10 18
9
4-300
4-250
10 11
200A
12 Plug–on Neutral Load Center Main Lugs, Convertible Mains (1Ø3W—120/240 Vac Rainproof—UL Listed) QO Plug-on Neutral Load Centers and CAFI Breakers are engineered for a quick Plug on Neutral connection on every unit. Table 1.24: Convertible Main Lugs Plug-on Neutral Load Center (Compatible with QO Plug-on Circuit Breakers and QO Plug-on Neutral Circuit Breakers) Mains Rating Spaces Max. Load Center Box and Interior Al Cu Equipment Ground Bar Kit (Factory Included) BoxNo. [20] Single Pole Circuits [15]
Max. Tandem Circuit Breakers
Convertible Mains — Factory-Installed Main Lugs — 65 kA Short Circuit Current Rating [21][18][22] QOM1 Main Circuit Breaker Frame Size, Convertible to Main Circuit Breaker — Equipment Ground Bar Included
R A I N P R O O F
QO112L125PGRB QO116L125PGRB QO124L125PGRB
12 16 24
24 24 34
12
6–2/0 6–2/0 6–2/0
PKGTALP1 PKGTALP1 PK15GTA
3R 4R 4R
125A
8
10
Convertible Mains — Factory-Installed Main Lugs — 65 kA Short Circuit Current Rating [21][18][22] QOM2 Main Circuit Breaker Frame Size, Convertible to Main Circuit Breaker — Equipment Ground Bar Included
QO112L200PGRB QO130L200PGRB QO140L200PGRB QO142L225PGRB
4–300
4–250
PKGTALP1 PK23GTAL PKGTALP2
5R 6R 7R 8R
12 30 40 42
24 40 60 52
12 10 20 10
200A
4–250
4–300
4–250
PK23GTA, LK100AN
225A
4–300
Above listings through 200 A mains rating meet Federal Specification W-P-115C as Type 1, Class 2.
[15] Maximum single pole branch circuits utilizing QO and/or QOT circuit breakers. [16] Order F for flush device or S for surface device. [17] See page 1-32 [18] UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only. [19] [9] 22 k AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10 k AIR branch circuit breakers to permit their application on systems with up to 22 kA available fault current. [20] See Table 1.76 Enclosure Dimensions, page 1-34 or Indoor Enclosure Dimensions and Knockout Information, page 1-32 [21] UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed. [22] Side hinge door device; allow 1-1/4 in. on left side for door to open.
1-12
© 2021 Schneider Electric All Rights Reserved July 30, 2021
Made with FlippingBook flipbook maker