Table 18.60: Component Parts for the Assembly of F-Line 3-pole Reversing Contactors With 2 Identical Contactors Set of Power Connections Cat. No. Mechanical Interlock Kit Cat. No. Horizontal Mounting LC1F115 LA9FF976 LA9FF970 LC1F150 LA9F15076 LA9FF970 LC1F185 LA9FG976 LA9FG970 LC1F225 LA9F22576 LA9FG970 LC1F265 LA9FH976 LA9FJ970 LC1F330 LA9FJ976 LA9FJ970 LC1F400 LA9FJ976 LA9FJ970 LC1F500 LA9FK976 LA9FJ970 LC1F630 or F800 LA9FL976 LA9FL970

LA9F●970

LA9F●976

TeSys™ F Contactors Table 18.61: Suppressor Blocks Operating limit: up to 220 V, 50/60 Hz coils Description For Use with coils

Catalog Number LA9F980

LX1FH, F265, F330

Suppressor block (clip-on mounting to coil)

LX1FJ, FK, FL, FX, F400, F500, F630, F780, LX9FF, FG, FH, F115, F150, F185, F225, F265, F330

18 CONTACTORS AND STARTERS-IEC

LA9D09980 LA9D09981

Mounting bracket (for 35 mm DIN rail or panel mounting) for suppressor block

LA9D09981, LA9F980

Table 18.62: Lugs and Terminal Shrouds for TeSys F Contactors Contactor TypeLC1 CableSize AWGRange

LugKit (Quantity of 6)

Individual Lug (Quantity of 1)

F115

14 to2/0 6 to3/0

DZ2FF6 DZ2FG6 DZ2FH6 DZ2FJ6 DZ2FK6 DZ2FL6 DZ2FL6 DZ2FX6

DZ2FF1 DZ2FG1 DZ2FH1 DZ2FJ1 DZ2FK1

F150, F185

F225, F265, F330

6 to300MCM 4 to500MCM 2x2to600MCM 3x2to600MCM 3x2to600MCM 4 x 1/0 to 750 MCM

F400 F500 F630 F800 F780

DZ2FL [29]

— —

Table 18.63: Lugs and Terminal Shrouds for TeSys F Contactor with TeSys F Overload Relay [30] Contactor Type LC1 Overload Relay (Direct Mount to Contactor) Contactor Line Side Lug (Qty) Line Side Cable Size AWG Range

Overload Load Side Lug (Qty)

Load Side Cable Size AWG Range

DZ2FF1 (3) DZ2FG6 (1) DZ2FG6 (1) DZ2FH1 (3) DZ2FJ1 (3) DZ2FK1 (3) DZ2FL1 (1) DZ2FL2 (1) DZ2FL3 (1)

DZ2FG1 (3)

LR9F5•57–F5•69, LR9F57–F69 LR9F5•57–F5•71, LR9F57–F71

F115

14 to2/0

6 to3/0 6 to3/0

(included with line side lug kit) (included with line side lug kit)

F150, F185

6 to3/0

F225, F265 F265, F330

LR9F5•71, LR9F71

6 to300MCM 6 to300MCM 4 to500MCM

6 to300MCM 4 to500MCM 4 to500MCM 4 to500MCM

LR9F7•75–F7•79, LR9F75–F79 LR9F7•75–F7•81, LR9F75–F81 LR9F7•75–F7•81, LR9F75–F81

— — —

F400 F500

2X2to600MCM

3X2to600MCM 4 to500MCM These clear plastic protective shrouds are an effective means to meet international touch-safe requirements for power terminals. They are designed to be used with power cables that have been bolted to the terminal. NOTE: The protection shrouds do not attach to contactors or overloads using DZ2F lugkits. DZ2FR1 (1)

LR9F7•81, LR9F81

F630

[28] For additional reversing accessory options, see Catalog MKTED210011EN. Check with local sales office for availability. [29] For 2–pole F630 contactors, order two DZ2FL1 (L1 and T2), and two DZ2FL3 (L2 and T1). For 4–pole F6304, order two DZ2FL1 (L1 and T4), four DZ2FL2 (L2, T2, L3, T3) and two DZ2FL3 (L4 and T1). [30] Lug kits ending in the number 6 include 6 identical lugs. In some cases the LR9F overload relay mounted directly on the load side of an LC1F contactor will require a different size lug for your choice of contactor and overload. If the two sizes are different, order 3 of each size lug. Mounting hardware (screws, washers, and nuts) are provided with the contactors and overload relays, not with the lugs.