SE Digest 178
Contactor Accessories
TeSys™ F Contactors
Refer to Catalog MKTED210011EN
www.se.com/us
TeSys™ F Reversing Contactors [28]
Table 18.60: Component Parts for the Assembly of F-Line 3-pole Reversing Contactors With 2 Identical Contactors Set of Power Connections Cat. No. Mechanical Interlock Kit Cat. No. Horizontal Mounting LC1F115 LA9FF976 LA9FF970 LC1F150 LA9F15076 LA9FF970 LC1F185 LA9FG976 LA9FG970 LC1F225 LA9F22576 LA9FG970 LC1F265 LA9FH976 LA9FJ970 LC1F330 LA9FJ976 LA9FJ970 LC1F400 LA9FJ976 LA9FJ970 LC1F500 LA9FK976 LA9FJ970 LC1F630 or F800 LA9FL976 LA9FL970
LA9F●970
LA9F●976
TeSys™ F Contactors Table 18.61: Suppressor Blocks Operating limit: up to 220 V, 50/60 Hz coils Description For Use with coils
Catalog Number LA9F980
LX1FH, F265, F330
Suppressor block (clip-on mounting to coil)
LX1FJ, FK, FL, FX, F400, F500, F630, F780, LX9FF, FG, FH, F115, F150, F185, F225, F265, F330
18 CONTACTORS AND STARTERS-IEC
LA9D09980 LA9D09981
Mounting bracket (for 35 mm DIN rail or panel mounting) for suppressor block
LA9D09981, LA9F980
Table 18.62: Lugs and Terminal Shrouds for TeSys F Contactors Contactor TypeLC1 CableSize AWGRange
LugKit (Quantity of 6)
Individual Lug (Quantity of 1)
F115
14 to2/0 6 to3/0
DZ2FF6 DZ2FG6 DZ2FH6 DZ2FJ6 DZ2FK6 DZ2FL6 DZ2FL6 DZ2FX6
DZ2FF1 DZ2FG1 DZ2FH1 DZ2FJ1 DZ2FK1
F150, F185
F225, F265, F330
6 to300MCM 4 to500MCM 2x2to600MCM 3x2to600MCM 3x2to600MCM 4 x 1/0 to 750 MCM
F400 F500 F630 F800 F780
DZ2FL [29]
— —
Table 18.63: Lugs and Terminal Shrouds for TeSys F Contactor with TeSys F Overload Relay [30] Contactor Type LC1 Overload Relay (Direct Mount to Contactor) Contactor Line Side Lug (Qty) Line Side Cable Size AWG Range
Overload Load Side Lug (Qty)
Load Side Cable Size AWG Range
DZ2FF1 (3) DZ2FG6 (1) DZ2FG6 (1) DZ2FH1 (3) DZ2FJ1 (3) DZ2FK1 (3) DZ2FL1 (1) DZ2FL2 (1) DZ2FL3 (1)
DZ2FG1 (3)
LR9F5•57–F5•69, LR9F57–F69 LR9F5•57–F5•71, LR9F57–F71
F115
14 to2/0
6 to3/0 6 to3/0
(included with line side lug kit) (included with line side lug kit)
F150, F185
6 to3/0
F225, F265 F265, F330
LR9F5•71, LR9F71
6 to300MCM 6 to300MCM 4 to500MCM
6 to300MCM 4 to500MCM 4 to500MCM 4 to500MCM
LR9F7•75–F7•79, LR9F75–F79 LR9F7•75–F7•81, LR9F75–F81 LR9F7•75–F7•81, LR9F75–F81
— — —
F400 F500
2X2to600MCM
3X2to600MCM 4 to500MCM These clear plastic protective shrouds are an effective means to meet international touch-safe requirements for power terminals. They are designed to be used with power cables that have been bolted to the terminal. NOTE: The protection shrouds do not attach to contactors or overloads using DZ2F lugkits. DZ2FR1 (1)
LR9F7•81, LR9F81
F630
[28] For additional reversing accessory options, see Catalog MKTED210011EN. Check with local sales office for availability. [29] For 2–pole F630 contactors, order two DZ2FL1 (L1 and T2), and two DZ2FL3 (L2 and T1). For 4–pole F6304, order two DZ2FL1 (L1 and T4), four DZ2FL2 (L2, T2, L3, T3) and two DZ2FL3 (L4 and T1). [30] Lug kits ending in the number 6 include 6 identical lugs. In some cases the LR9F overload relay mounted directly on the load side of an LC1F contactor will require a different size lug for your choice of contactor and overload. If the two sizes are different, order 3 of each size lug. Mounting hardware (screws, washers, and nuts) are provided with the contactors and overload relays, not with the lugs.
18-22
© 2021 Schneider Electric All Rights Reserved July 30, 2021
Made with FlippingBook flipbook maker