2-Pole Single Phase—NEMA 7 & 9 and 12/3R NOTE: In Table 16.94, replace ●●● with the voltage code shown in . For melting alloy thermal units, see page 16-132. For information on field modification of NEMA 12 enclosures, see page 16-112.
Table 16.94: 2-Pole Single Phase—600 Vac Maximum—50–60 Hz (require 1 melting alloy thermal unit)
NEMA7&9 Hazardous Locations, Div. 1 & 2 Class I, Groups C & D Class II, Groups E, F, & G
NEMA12/3R [24] Dusttight & Driptight Industrial Use Enclosure
NEMA Size 16 NEMA AND DEFINITE PURPOSE CONTACTORS AND STARTERS Continuous Current Ratings
Motor Voltage
Max. Hp
Bolted Type
SpinTop™ Type
Type
Cast Iron [25]
Cast Aluminum [26]
115 230 115 230 115 230 115 230 115 230
1/3 1
UseSize0
UseSize0
UseSize0
00
9
1 2 2 3 3 5
SBT1●●●
SBT41
SBR1●●●
SBA1●●●
0
18
SCT1●●●
SCT41
SCR1●●●
SCA1●●●
1
27
SCT2●●●
SCT42
SCR2●●●
SCA2●●●
1P
36
3 7-1/2
SDT6●●●
SDT46
SDR6●●●
SDA6●●●
2
45
4-Pole, 2-Phase—NEMA 7 & 9 and 12/3R NOTE: In Table 16.95, replace ●●● with the voltage code shown in . For melting alloy thermal units, see page 16-132. For information on field modification of NEMA 12 enclosures, see page 16-112.
Table 16.95: 4-Pole 2-Phase—600 Vac Maximum—50–60 Hz (require 2 melting alloy thermal units)
NEMA7&9 Hazardous Locations Class I, Groups C & D Class II, Groups E, F, & G
NEMA12/3R [24] Dusttight & Driptight Industrial Use Enclosure
Continuous Current Ratings
Motor Voltage
Max. Hp
Coil Voltage
NEMA Size
Bolted Type
SpinTop™ Type
Type
Cast Iron [25]
Cast Aluminum
208 240 480 600 208 240 480 600 208 240 480 600 208 240 480 600 208 240 480 600
3 3 5 5
200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575
SBT3●●●
SBR3●●●
SBA3●●●
0
18
7-1/2 7-1/2
SCT4●●●
SCR4●●●
SCA4●●●
1
27
10 10 10 15 25 25 25 30 50 50 40 50
Consult the Customer Care Center at 1-888-778-2733
2
45
SDT2●●●
SDR2●●●
SDA2●●●
3
90
SER2●●●
SEA2●●●
Consult the Customer Care Center at 1-888-778-2733
4
135
—
SFA2●●●
100 100
Dimensions: page 16-39 Factory Modifications (Forms): page 16-117 Separate Enclosures (Class 9991): page 16-110 Replacement Parts (Class 9998): page 16-122 Type S Accessories (Class 9999): page 16-125 For How to Order Information, see page 16-28.
[24] NEMA 12 enclosures can be field modified for outdoor non-corrosive and non–service entrance rated applications. [25] Limited to one pilot light, and a selector switch or Start-Stop push button. [26] NEMA 7 and 9 bolted cast aluminum are not UL listed.
16-36
© 2019 Schneider Electric All Rights Reserved
11/20/2019