SE Digest 178
NF Panelboard Accessories
NF Panelboards—600Y/347 Vac Max.
Accessories
www.se.com/us
NF Merchandised and Factory Assembled Accessories
Table 9.74: NF Merchandised Interiors with Surge Protection Devices (SPD) Available Pole Spaces Main Rating Main Circuit Breaker Adapter Kit Main Circuit Breaker Frame Interior Only Catalog No. [61] Surge Current Rating
NEMA 1 Enclosure Mono-Flat Front
NEMA3R, 5, 12 Enclosure
Hinged Front
Box
Main Lug Only
NC56( ) NC68( ) NC68V( ) NC80V( )
NC56( )HR MHWP56 NC68( )HR MHWP68 NC68V( )HR MHWP68 NC80V( )HR MHWP80
MH56 MH68 MH68 MH80
250A
NF442L2TVS416C
N250MJ [62]
JD/JG/JJ/JL
160kA
42
Main Lug Only
400A
NF442L4TVS416C
N400M [63]
LA/LH
Accessories
Table 9.75: NF Merchandised Neutrals Mains Ampacity
Copper 100% Neutral Kit
200% Neutral Kit
Catalog No.
Catalog No.
125 250 400 600
NFNL1 NFNL2
NFN1CU NFN2CU NFN6CU
NFNL4 [64]
Factory Assembled Only
NFN6CU [64]
Table 9.76: NF Merchandised Interior Modification Kits Mains Ampacity Sub-feed Lugs [65] Feed-through Lugs [65] Catalog No. Catalog No.
9 PANELBOARDS
Sub-feed Circuit Breaker Kits [65] (circuit breaker not Included)
Mains Ampacity
Single Sub-feed Circuit Breaker
Twin Sub-feed Circuit Breakers
Catalog No.
Catalog No.
125 250 400 600 800
NF125SFL NF250SFL
NF125FTL NF250FTL NF400FTL
250 400 600 800
NF250SFBH/NF250SFBJ
—
NF600SFBH NF600SFBJ
NF400SFL [66]
N600MPPL
Factory Assembled Only
Factory Assembled Only
Factory Assembled Only NOTE: NF250SFBH and NF600SFBH are for use with HDL, HGL, HJL, HLL, and HRL circuit breakers. NF250SFBJ and NF600SFBJ are for use with JDL, JGL, JJL, JLL, and JRL circuit breakers. Table 9.77: NF Special Features Standard NEMA Type 1 Enclosure Selection Table—Enclosure Catalog Number for Standard Main Mechanical Lugs Only Feature Main Lugs Only Sub-feed Lugs Feed-through Lugs Sub-feed Circuit Breaker Interior Rating 125 A 250 A 400 A 600 A 800 A 125 A 250 A 400 A 600 A 800 A 250 A 400 A 400A [67] 600A 600A [67] 800A No. of Circuits NEMA 1 Enclosure Catalog Number NEMA 1 Enclosure Catalog Number NEMA 1 Enclosure Catalog Number 18 MH26 — — — — MH32 — — — — — — — — — Factory Assembled Only 30 MH32 MH38 MH50 Factory Assembled Only MH38 MH50 MH56 Factory Assembled Only MH56 MH68 MH62D9 MH68 MH62D9 42 — MH44 MH56 — MH56 MH62 MH62 MH74 MH68D9 MH74 MH68D9 54 — MH50 MH62 — MH62 MH68 MH68 MH80 MH74D9 MH86 MH74D9 66 — MH62 MH74 — MH74 MH80 MH80 MH92 — MH92 — 84 — — MH86 — — — — — — — — Table 9.78: Special Features Enclosures Selection Table—Merchandised NF Vertically Mounted Main Breaker Panelboards with Accessories (by Mains Rating)
Vertical Main Circuit Breaker (MB) [68]
Back-fed MB
Sub-feed Circuit Breaker (PowerPacT H or J)
Feed-through Lugs (FTL)
FTL
No. of Circuits
400A [68] Cat.No.
125A
250A
400A
600A
800A
125A
250A
600A
125A
Cat.No.
Cat.No.
Cat.No.
Cat.No.
Cat.No.
Cat.No.
Cat.No.
Cat.No.
Cat.No.
18 30 42 54 66
— — — — —
—
—
—
—
MH44 MH50
—
—
—
MH32 MH38
MH68 MH74 MH80 MH92
MH80 MH86 MH92
MH62 MH68 MH74 MH86
MH68 MH74 MH86 MH92
Factory Assembled Only
Factory Assembled Only
Factory Assembled Only
— — —
— — —
—
—
Table 9.79: Optional Main Lug Kits for Main Lug Panelboards Ampacity Al Compression Lug Kit
Cu Mechanical Lug Kit
Cu Compression Lug Kit [66]
Catalog No. NFALV1 [69]
Lug Wire Range
Catalog No.
Lug Wire Range
Catalog No. NFCUV1 [70] NFCUV2 [70]
Lug Wire Range one #6–1/0 AWG
125 250 400 600 800
one #4 AWG–300 kcmil
NFCUM1 NFCUM2 NFCUM4 NFCUM6
#6–2/0AWG
NFALV2 NFALV4 NFALV6
one 250–350 kcmil
#6 AWG–250 kcmil
one 2/0 AWG–300 kcmil
one 1/0 AWG–750 kcmil, or two 1/0 AWG–350 kcmil two 1/0 AWG–750 kcmil
NFCUV4 NFCUV6
one 400–750 kcmil two 250–500 kcmil
two 2/0 AWG–500 kcmil two 2/0 AWG–500 kcmil
Contact your local Schneider Electric representative or distributor.
[61] Order branch circuit breakers separately. [62] Select the appropriate PowerPacT main circuit breaker from Section 7. [63] Select an appropriate LA or LH Thermal-Magnetic Circuit Breaker from Section 7. [64] Not to be used with SFL, FTL, or SFB. These combinations are factory assembled only. [65] Available factory assembled only on non-linear panelboards. [66] Use copper wire only. [67] PowerPacT LG, LJ, LL, or LR Sub-Feed Circuit Breaker. [68] 400 A dimension for LA/LH main circuit breakers only. [69] Use of this kit requires an additional 6 in. added to box height. [70] Use of this kit to terminate larger than standard wire size requires an additional 6 in. added to box height.
9-35
© 2021 Schneider Electric All Rights Reserved 6/20/2021