SE Digest 178
MicroLogic™ Electronic Trip Units
MicroLogic™ Trip Unit Accessories
Class 612, 612 / Refer to Catalogs 0611CT1001 and 0612CT0101
www.se.com/us
Trip Unit Accessories
Adjustable rating plug "A" is installed as standard on all MicroLogic trip unit orders. However, an alternative selection may be specified from the "Assembled" table below, and factory installed with your trip unit order at no additional charge. To order, please attach the appropriate catalog suffix to the end of the trip unit Cat. No. (after specifying trip unit options). Adjustable rating plugs may also be purchased as field-installable components from the table below. For Enerlin’X accessory information, see Enerlin’X Digital Solutions, page 7-81
Sensor Plug
Trip Unit Seal
Table 7.126: Rating Plugs Rating Plug [7]
Table 7.129: Trip Unit Accessories Device
Factory Installed Cat. Suffix
Field-Installable Cat. No.
Frame
Cat. No. S434206
Pocket Tester UTATester
A (standard)
A B C D E F G H
S48818 S48819 S48820 S48836 S48837 S48838 S48839 S48840
STRV00910 STRV00911 SVW3A8114 TRV00915 TRV00917
Spare UTA Tester
B C D E F G H
H/J/L
Bluetooth/Modbus for UTA Tester
Spare Power Supply for UTA Tester (110–120 Vac)
MicroLogic Cord for UTA Tester MicroLogic 5/6 Cover, Transparent MicroLogic 2/3 Cover, Transparent MicroLogic 5/6 Cover, Transparent MicroLogic 2/3 Cover, Transparent LCD Display for MicroLogic 5 LCD Display for MicroLogic 6
S429478 S429481 S432459 S432461 S429483 S429484 S33594 S33937 LV485500
H/J
L
Table 7.127: Neutral Current Transformers UseWith Cat. No. Sensor H-Frame S429521 60–100 S430562 150 J-Frame S430563 250 L-Frame S432575 400–600 P-Frame S33575 [8] 250 S33576 [8] 400–1600
H/J/L
Hand-held Test Kit
Primary Injection Test Adaptor
Service Interface Kit [9]
P/R
Seven-pin Test Cable (for connection between test kit and trip unit) [10] Two-pin Test Cable (for connection between test kit and trip unit) [11]
S48907 S48908
S48916 [8] S34036 [8] S48896 [8] S48182 [8]
250
M2CTEST (for isolated trip unit testing) [12]
M2CTEST
400–1600
230 Vac Filtered Power Cord [13] 120 Vac Filtered Power Cord [13]
R-Frame
S48856 S48855 S33593
2000 3000
P/R
Trip Unit Battery for Trip Indicator Lights
All All Table 7.128: Zone-Selective Interlocking Description Factory-Installed Cat. Suffix NCTWIRING
24–30 Vdc input 48/60 Vdc input 125 Vdc input 110–130 Vac input 200–240 Vac input
LV454440 LV454441 LV454442 LV454443 LV454444
Power supply with:
Field-Installable Cat.No.
ZSI Interface Module 24 Vdc Terminal Block ZSI Wire Harness, H/J Frame ZSI Wire Harness, L-Frame ENCT & ZSI Wire Harness
—
S434212 S434210 S434300 S434301
EN
MicroLogic A Trip Unit Cover, clear
S33592 S47067
P/R
MicroLogic P/H Trip Unit Cover, opaque gray
YH3 YH3 YH4
Trip Unit Seal (6 pieces) for compliance with NEC 240.6(c) 12-pin Trip Unit Connector for NT/NW MasterPact Circuit Breakers 12-pin Trip Unit Connector for P- and R-Frame Circuit Breakers
H/J/L/P/R MICROTUSEAL
S33101 S33100 685831
—
P/R
Battery Back-up (12 Hours)
Table 7.130: Sensor Plugs for P- and R-Frame Circuit Breakers [14] Description Sensor Plug Range Sensor Plug Cat. No.
Circuit Breaker Frames Accepting Sensor Plug
1250A [15]
600A 630A [15]
P-Frame Circuit Breaker
250A 400A
800 A 1000 A 1200 A
1600A
250A 400A 600A 800A 1000A 1200A 630A 800A 1000A 1250A 1600A 600A 800A 1000A 1200A 1600A 2000A 2500A 3000A 1600A 2000A 2500A 3200A
S47052 S47053 S48823 S33092 S33093 S48824 S33091 S33092 S33093 S33094 S33095 S48823 S33092 S33093 S48824 S33095 S33982 S33983 S48825 S33095 S33982 S33983 S33984
X
— — — — — — — —
—
X
X X
— —
X X X
— — — —
— —
X X X X X X
X X X X
— — — — — — — —
UL
— — — — — — — — — — — — — — —
— — —
X
X X
— — —
X X X X
X X X X X
— — — — — — — — —
IEC
— — — — — — — — — — — — — — — 600 A 800 A 1000 A 1200 A 1600 A 2000 A 2500 A 3000 A 3200 A
R-Frame Circuit Breaker
X
X X
X X X
X X X X
— — — — — — — — —
—
X X X X
— —
X X X X
— — —
— — —
X X X X X X X
— —
UL
7 MINIATURE AND MOLDED CASE
— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — X X X — — — — — — — — X X X X X X X
— — — —
X X X X
IEC
CIRCUIT BREAKERS
[7] Long-time pickup amperes (Ir) = Sensor Rating (In) X Setting of rating plug. “Fine adjustment tuning” is included on MicroLogic Power and Harmonic trip units, allowing for incremental settings of 1 A between the plug setting and.40 X Sensor Rating. [8] Includes NCTWIRING kit. [9] Service Interface Test Kit can be ordered through SE Services only. Service Interface Test kit replaces obsoleted Full Function Test Kit. [10] Used for testing MicroLogic trip units. Included in the price of the Hand-held/Full-function Test Kits. Kit for replacement only. [11] Used for testing STR trip units. Included in the price of the Hand-held/Full-function Test Kits. Kit for replacement only. [12] Required for Arc Energy Reduction Performance Testing for Instantaneous setting or Maintenance Mode Switch when using a Full Function Test Kit [13] Included with the Full-function Test Kit. Kit for replacement only. [14] For use only with circuit breakers with date codes later than 07011. For long-time pickup range, See rating plug information at page 7-61. [15] IECOnly.
7-64
© 2021 Schneider Electric All Rights Reserved July 30, 2021