SE Digest 178
Sepam™ Protection Relays
Sepam™ 20 Ordering Configurations
www.se.com/us
Sepam™ 20 Configuration
Table 5.7: Sepam Series 20 Configuration Model Description
RelayBase Model
_
_
_
_
_
_
_
_
S24 — Substation Relay B22 — Busbar Relay
SQ1S24 SQ1B22 SQ1M20 SQ1T24
S24 B22 M20 T24
Display Current
Logipam Synch Check
Coms I/O RTDs Analog Out
M20 — Motor Relay
T24 — Transformer Relay
Advanced Display
A R
Remote Advanced Display
DSM303
Voltage Inputs Only (Required for Busbar Relays
0 1 2 3
1A/5A CT inputs
CCA634 CCA630 CCA670 MES114 MES114F ACE959
Alt. 1A/5A CT inputs (requires CSH120, 200 or 30)
Low Power CT (LPCT)
10In/4Out, 24–48Vdc/120–250Vac
A B C
MES114E 10In/4Out, 110–125Vdc/110Vac
10In/4Out, 220–250Vdc/220–220Vac
1xRS485
1 2 3
ACE969TP2 2 x RS485
ACE969FO2 1 x RS485/ 1 x Fiber Optic
without (not available on Substation or Busbar relays)
A B
8 Temp sensor inputs
MET1482
without
0 1
1 x Analog 0–1mA, 0–10mA, 0–20mA, 4–20mA output
MSA141
Without (80 Series Only) Without (80 Series Only)
A
0
Table 5.8: Sepam Series 20 Typical Catalog Numbers Catalog Numbers
Description
Series 20 - Substation/Feeder Protection S24 (24-250Vdc & 120-240Vac), 1/5A CT inputs, 10In/8Out (110-125 Vdc, 110Vac), RS485 Series 20 - Motor Protection M20 (24-250Vdc & 120-240Vac), 1/5A CT inputs, 10In/8Out (110-125 Vdc, 110Vac), 8 RTD's, RS485 Series 20 - Transformer Protection T24 (24-250Vdc & 120-240Vac), 1/5A CT inputs, 10In/8Out (110-125 Vdc, 110Vac), RS485 Series 20 - Voltage Protection B22 (24-250Vdc & 120-240Vac), Voltage Inputs ONLY, 10In/8Out (110-125 Vdc, 110Vac), RS485 Also refer to Sepam Series 20 on www.schneider-electric.us. Sepam 40 Configuration
SQ1S24A1B1A0A0 SQ1M20A1B1B0A0 SQ1T24A1B1A0A0 SQ1B22A0B1A0A0
Table 5.9: Sepam Series 40 Configuration Model Description
RelayBase Model
_
_
_
_
_
_
_
_
S42 - Substation Relay G40 - Generator Relay
SQ1S42 SQ1G40 SQ1M41 SQ1T42
S42 G40 M41 T42
M41 - Motor Relay 5 PROTECTION, CONTROL, AND ENERGYAUTOMATION Advanced Display 1A/5A CT inputs
Display Current
Logipam Synch Check
Coms
I/O RTDs Analog Out
T42 - Transformer Relay
A R
Remote Advanced Display
DSM303 CCA634 CCA630 CCA670 MES114
1 2 3
Alt. 1A/5A CT inputs (requires CSH120, 200 or 30)
Low Power CT (LPCT)
10In/4Out, 24-48Vdc/120-250Vac
A B C
MES114E 10In/4Out, 110-125Vdc/110Vac* MES114F 10In/4Out, 220-250Vdc/220-240Vac
ACE959
1xRS485
1 2 3 5 6
ACE969TP2 2 x RS485
ACE969FO2 1 x RS485/ 1 x Fiber Optic
ACE850TP 2 x Ethernet Ports (Copper, IEC61850/ModbusTCP) ACE850FO 2 x Ethernet Ports (Fiber, IEC61850/ModbusTCP)
without
A B C
8 Temp sensor inputs (One Module)
MET1482
2 x MET1482 16 Temp sensor inputs (Two Modules)
without
0 1
1 x Analog 0-1mA, 0-10mA, 0-20mA, 4-20mA output
MSA141
without (80 Series Only) without (80 Series Only)
A
0
Table 5.10: Sepam Series 40 Typical Catalog Numbers Catalog Numbers
Description
Series 40 Substation/Feeder Protection S42 (24-250Vdc & 120-240Vac), 1/5A CT inputs, 10In/8Out (110-125 Vdc, 110Vac), RS485 Series 40 Substation/Feeder Protection S42 (24-250Vdc & 120-240Vac), 1/5A CT inputs, 10In/8Out (110-125 Vdc, 110Vac), 2 x RJ-45 Ethernet - Modbus/IEC61850 Series 40 Motor Protection M41 (24-250Vdc & 120-240Vac), 1/5A CT inputs, 10In/8Out (110-125 Vdc, 110Vac), 8 RTD's, RS485 Series 40 Transformer Protection T42 (24-250Vdc & 120-240Vac), 1/5A CT inputs, 10In/8Out (110-125 Vdc, 110Vac), RS485 Series 40 Generator Protection G40 (24-250Vdc & 120-240Vac), 1/5A CT inputs, 10In/8Out (110-125 Vdc, 110Vac), RS485 Also refer to Sepam Series 40 on www.schneider-electric.us.
SQ1S42A1B1A0A0 SQ1S42A1B5A0A0 SQ1M41A1B1B0A0 SQ1T42A1B1A0A0 SQ1G40A1B1A0A0
5-8
© 2019 Schneider Electric All Rights Reserved
11/20/2019