Sepam Protection Configurations Three relay series with increasing protection capabilities for six types of applications to provide all possible protection configurations
Table 5.2: Sepam 20, 40 and 80 Protection Functions ANSI Device Number Description
Sepam 20/40 Relay Models Sepam 80 Relay Models S24 M20 B22 S40 T40 T42 M41 G40 S84 M87 M88 T87 G87 G88 C86 B80 B83
Speed Switch
12/14
●
●
● ●
● ● ● ●
Underimpedance
21B
24 25 26 27
Volts/Hertz Synch Check Thermostat
● ● ● ● ● ●
●
● ●
● ●
● ● ●
●
Phase-to-phase Undervoltage Positive sequence Undervoltage
●●●●●●●●●●●●●●●
27D 27R 27S
● ●
● ●
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Remnant Undervoltage
Phase-to-neutral Undervoltage
●●●●●●●●●●●●●●●
Third Harmonic Neutral Undervoltage
27TN
● ●
32P
Directional Power
● ● ● ● ● ● ● ●
32Q/40/55 Directional Reactive Power
● ●
● ●
● ●
37 38 40 46 47 48 49
Phase Undercurrent Bearing Temperature Loss of Excitation
● ●
●
● ● ●
● ● ● ●
● ● ● ● ● ●
● ●
● ●
● ●
Negative Sequence Current/Unbalance Negative Sequence Undervoltage
● ●
●●●●●●●●●●●●●● ●●●●●●●●●●●●●●●
Excessive Starting Time
● ● ●
●
● ●
Thermal Overload RTD Monitoring Breaker Failure
●●●●●●●●●●●
49T
● ● ● ●
● ● ● ● ● ●
50BF 50/27 50G 50N 50V 51C 51G 51N 50V 51V 51 51LR 50
●
●●●●●●●●●●●●●●
Inadvertent Energization
● ●
Instantaneous Phase Overcurrent
● ●
●●●●●●●●●●●●●● ●●●●●●●●●●●●●● ●●●●●●●●●●●●●●
Instantaneous Ground Overcurrent (Measured) Instantaneous Ground Overcurrent (Calculated) Voltage Restrained Instantaneous Overcurrent
●
● ●
● ● ●
Time Phase Overcurrent Capacitor Bank Unbalance
● ●
●●●●●●●●●●●●●●
●
Time Ground Overcurrent (Measured) Time Ground Overcurrent (Calculated)
●
●●●●●●●●●●●●●● ●●●●●●●●●●●●●●
● ●
Locked Rotor
●
●
● ●
Voltage Restrained Instantaneous Overcurrent
● ●
Voltage Restrained Time Overcurrent
● ●
Phase-to-phase Overvoltage Neutral Voltage Displacement
59
●●●●●●●●●●●●●●● ●●●●●●●●●●●●●●●
59N 5 PROTECTION, CONTROL, AND ENERGYAUTOMATION 63 Buchholz Pressure 64G 64REF 66 67 Starts per hour 67N
● ●
●
100% Stator Ground Fault Restricted Ground Fault
● ●
●
●
●
● ●
Directional Phase Overcurrent Directional Ground Overcurrent
● ●
●
● ● ●
● ● ●
● ● ● ●
PoleSlip Reclosing
78 79
● ●
●
●
●
Overfrequency Underfrequency
81H 81L 81R
●●●●●●●●●●●●●●● ●●●●●●●●●●●●●●●
Rate of Change of Frequency
●
●
87M Machine Differential
●
●
2 Winding Transformer Differential
87T
● ●
●
5-6