Square D Digest 179

Motor Starters and Protectors

TeSys™ Ultra Combination Motor Controllers Refer to Catalog MKTED210011EN

www.se.com/us

TeSys™ Reversing Starters

Table 17.80: Power Base with Reversing Unit assembled under the base Control Connection Max. Current (A) Maximum Horsepower Ratings Three-Phase Single-Phase 200 V 230 V 460 V 575 V 115 V 230 V

Self-Protected Starter Base

Catalog Number LU2B12 [7] LU2B32 [7]

12 32

3

3

7.5

10 25

1.5

2 5

Withscrew terminations

10

10

20

2

Table 17.81: Select Control Unit Options [8][9] Setting Range (A) Standard Three-Phase Class 10 trip [10] Advanced Three-Phase Class 10 trip [10]

Advanced Single-Phase Class 10 trip [10]

Advanced Three-Phase Class 20 trip [10]

0.15–0.6 0.3–1.4 1.25–5.0

LUCAX6●● LUCA1X●● LUCA05●● LUCA12●● LUCA18●● LUCA32●●

LUCBX6●● LUCB1X●● LUCB05●● LUCB12●● LUCB18●● LUCB32●●

LUCCX6●● LUCC1X●● LUCC05●● LUCC12●● LUCC18●● LUCC32●●

LUCDX6●● LUCD1X●● LUCD05●● LUCD12●● LUCD18●● LUCD32●●

3–12

Reverser Unit Assembled under the Power Base

4.5–18

8–32

Table 17.82: Voltage Codes Volts

17 CONTACTORS AND STARTERS-IEC

24

110–240

BL [11][12]

DC AC

— —

B

DCorAC

FU

Table 17.83: Reversing Modules for Field Addition Mounting Catalog No. Wiring Adapter Beneath LU2MB0 LU9MR1C

Note: For LU2MB0 and LU6MB0, voltage code required; must match control unit.

Beside

LU6MB0

LU9MR1

TeSys™ Ultra Accessories Table 17.84: Current Limiter [13][14] Accessory Application

Mounting

Technical Data 130 kA at 460 V 65 kA at 575 V 130 kA at 460 V 65 kA at 575 V

Cat.No. LUALB1

Additional current limiting aspects for the starter Replacement cartridge for LUALB1

Direct mounting to LUB● and LU2B●

Current limiter/isolator

Limiter cartridge

LUALF1

Table 17.85: Function Modules [13][15] Module Description

Operation Requirements 24–250 Vac/Vdc (power from control unit) 24–250 Vac/Vdc (power from control unit) 4–20mA (requires separate 24 Vdc power supply)

Catalog Number

For use with:

Fault differentiation: with manual reset (thermal overload) with auto reset Thermal overload pre-alarm

Provides indication between an overload trip and a short circuit trip.

Advanced control unitsonly

LUFDA10

Signals when the motor current reaches 1.05 of the full load setting on the control unit. Provides a signal proportional to the average currents in the three phases divided by the full load current setting of the control unit. The output corresponds to a load status of 0–2 times the full load setting of the control unit. Provides a convenient way to reduce control wiring and allow for connecting starters to a communications network by providing 24 Vdc for the starters.

Advanced control unitsonly

Alarm Differentiation

LUFW10

Advanced or multi function control units

Motor load indication

LUFV2

Parallel Wiring

Motor Load Indicator

Advanced or multi function control units (24 Vdc only) and LU9BN11C or LU9MRC prewired connector

LU9G02 splitter box and PLC network

Parallel wiring

LUFC00

Voltage code required.

[7]

[8] The control unit contains solid-state overload relay and control power source for TeSys Ultra. For more details on the different control units, their functions, and placement on the power base see Control Units and Functions, page 17-27. [9] Control units for 4.5–18 and 8–32 can be used only with 32 A rated power bases (LUB32, LUB320, and LU2B32). [10] Complete the catalog number by adding the appropriate code from (for example LUCAX6FU). [11] DC voltage with range of 0.90 to 1.10 of nominal. [12] Voltage code to use for a power base with a communication module.

[13] See page 17-27 for placement on the power base. [14] Increases the breaking capacity of the motor starter. [15] Offers customization for specific application requirements.