Square D Digest 179
TeSys™ T Motor Management System
Protection Components
Refer to Catalog MKTED210011EN
www.se.com/us
Components
Table 16.280: Current Transformers Current Transformer Ratio [1]
Catalog Number
100:1 200:1 400:1 800:1
LT6CT1001 LT6CT2001 LT6CT4001 LT6CT8001
Table 16.281: Ground Fault Sensors Rated Operational Current le (A)
Internal Toroid Ø (mm)
Catalog Number
Closed Toroids, Type A 65
30 50 80
50437 50438 50439 50440 50441 50442 50485 50486
85
LT6CT4001
160 250 400 630
120 200 300
Split Toroids, Type QA 85
46
250
110
NOTE: Dimensional drawings are in catalog DIA1ED2061002EN-US. Table 16.282: PTC Thermistor Probes [2] Description Nominal Operating Temperature (NOT) °C Color
Catalog Number [3]
16 NEMA AND DEFINITE PURPOSE CONTACTORS AND STARTERS
Triple Probes
Green/green Brown/brown Gray/gray Blue/blue White/blue Black/black
90
DA1TT090 DA1TT110 DA1TT120 DA1TT130 DA1TT140 DA1TT150 DA1TT160 DA1TT170
110 120 130 140 150 160 170
DA1TT●●
Blue/red
White/green
Configuration with SoMove™ Software The TeSys™ T configurator is incorporated in the SoMove software application, versions 2.2 and higher. SoMove software allows configuration, commissioning and maintenance of motor starters protected by a TeSys T controller. A library containing predefined motor control mode functions is available in order to: • allow standardization • avoid errors • reduce motor starter setup times By using logic functions, a custom mode makes it possible to: • easily adapt these predefined motor control mode functions to the specific needs of your applications • create new functions The functions thus defined can be saved and used to build your function library for future applications. To create special functions, a logic editor is incorporated in the configurator and allows a choice of 2 programming languages:
• function block • structured text Table 16.283: Configuration Tools Description
Composition
Catalog Number
1 x 3 m length cable with two RJ45 connectors VW3A8106 1 RS232/RS485 converter with one 9-pin female SUB-D connector and one RJ45 connector.
Connection kit for PC serial port for Modbus™ PLC multidrop connection USB serial port adapter [4] for connecting a TeSys T controller to your PC USB serial port cable for connecting a TeSys T controller to your PC
1 USB / serial port adapter [4]
TSXCUSB485
1 USB / serial port cable
TCSMCNAM3M002P
[1] For use with LTMR08●● controllers. Three current transformers are required for 3-phase applications. [2] PTC: Positive Temperature Coefficient. [3] Sold in lots of 10. [4] Modbus RS–485 cable required, not included.
16-107
© 2024 Schneider Electric All Rights Reserved
Made with FlippingBook Ebook Creator