Square D Digest 179

TeSys™ T Motor Management System

Protection Components

Refer to Catalog MKTED210011EN

www.se.com/us

Components

Table 16.280: Current Transformers Current Transformer Ratio [1]

Catalog Number

100:1 200:1 400:1 800:1

LT6CT1001 LT6CT2001 LT6CT4001 LT6CT8001

Table 16.281: Ground Fault Sensors Rated Operational Current le (A)

Internal Toroid Ø (mm)

Catalog Number

Closed Toroids, Type A 65

30 50 80

50437 50438 50439 50440 50441 50442 50485 50486

85

LT6CT4001

160 250 400 630

120 200 300

Split Toroids, Type QA 85

46

250

110

NOTE: Dimensional drawings are in catalog DIA1ED2061002EN-US. Table 16.282: PTC Thermistor Probes [2] Description Nominal Operating Temperature (NOT) °C Color

Catalog Number [3]

16 NEMA AND DEFINITE PURPOSE CONTACTORS AND STARTERS

Triple Probes

Green/green Brown/brown Gray/gray Blue/blue White/blue Black/black

90

DA1TT090 DA1TT110 DA1TT120 DA1TT130 DA1TT140 DA1TT150 DA1TT160 DA1TT170

110 120 130 140 150 160 170

DA1TT●●

Blue/red

White/green

Configuration with SoMove™ Software The TeSys™ T configurator is incorporated in the SoMove software application, versions 2.2 and higher. SoMove software allows configuration, commissioning and maintenance of motor starters protected by a TeSys T controller. A library containing predefined motor control mode functions is available in order to: • allow standardization • avoid errors • reduce motor starter setup times By using logic functions, a custom mode makes it possible to: • easily adapt these predefined motor control mode functions to the specific needs of your applications • create new functions The functions thus defined can be saved and used to build your function library for future applications. To create special functions, a logic editor is incorporated in the configurator and allows a choice of 2 programming languages:

• function block • structured text Table 16.283: Configuration Tools Description

Composition

Catalog Number

1 x 3 m length cable with two RJ45 connectors VW3A8106 1 RS232/RS485 converter with one 9-pin female SUB-D connector and one RJ45 connector.

Connection kit for PC serial port for Modbus™ PLC multidrop connection USB serial port adapter [4] for connecting a TeSys T controller to your PC USB serial port cable for connecting a TeSys T controller to your PC

1 USB / serial port adapter [4]

TSXCUSB485

1 USB / serial port cable

TCSMCNAM3M002P

[1] For use with LTMR08●● controllers. Three current transformers are required for 3-phase applications. [2] PTC: Positive Temperature Coefficient. [3] Sold in lots of 10. [4] Modbus RS–485 cable required, not included.