Type S Reversing Full Voltage Contactors and Starters
Contactors, Type S
www.se.com/us
Class 8702 / Refer to Catalog 8502CT9701
Single-Phase and 4–Pole Polyphase NOTE: In Table 16.161, replace the three bullets (●●●) in the catalog number with the coil voltage code. Refer to the standard coil voltage codes listed in Table 16.160. For information on field modification of NEMA 12 enclosures, see page 16-113 .
Table 16.161: 600 Vac Maximum—50–60 Hz
NEMA1 General Purpose Enclosure
NEMA4X Watertight, Dusttight Brushed Stainless Steel Enclosure
NEMA12/3R [6] Dusttight & Driptight Industrial Use Enclosure
OpenType
Continuous Current Ratings
Motor Voltage
Max. Hp
NEMA Size
Typeof Motor
2-Pole Single Phase 00 16 NEMA AND DEFINITE PURPOSE CONTACTORS AND STARTERS 9
Vertical Type
Horizontal Type
Type
Type
Type
115 230 115 230 115 230 115 230 115 230 115 230 115 230 115 230 115 230 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575
1/3 1
—
SAO1●●●
SAG1●●●
UseSize0
UseSize0
Single Phase 3-Wire
1 2 2 3
SBO9●●●
SBO1●●●
SBG1●●●
SBW11●●●
SBA1●●●
0
18
SCO1●●●
SCO2●●●
SCG2●●●
SCW11●●●
SCA1●●●
1
27
3-Pole Single Phase
4-Wire Rep.-Ind. 4-Wire Split Ph. 4-Wire Rep.-Ind. 4-Wire Split Ph. 4-Wire Rep.Ind. 4-Wire Split Ph.
1/3 1 1/3 1
—
SAO2●●●
SAG2●●●
UseSize0
UseSize0
00
9
—
SAO3●●●
SAG3●●●
UseSize0
UseSize0
1 2 1 2 2 3 2 3 3 3 5 5
SBO10●●●
SBO2●●●
SBG2●●●
SBW12●●●
SBA2●●●
0
18
SBO11●●●
SBO3●●●
SBG3●●●
SBW13●●●
SBA3●●●
SCO3●●●
SCO4●●●
SCG4●●●
SCW12●●●
SCA2●●●
1
27
SCO5●●●
SCO6●●●
SCG6●●●
SCW13●●●
SCA3●●●
4-Pole Polyphase
0
18
SBO13●●●
SBO5●●●
SBG5●●●
SBW15●●●
SBA5●●●
7.5 7.5 10 10
SCO9●●●
SCO10●●●
SCG10●●●
SCW15●●●
SCA5●●●
1
27
10 15 25 25 25 30 50 50 40 50
2Phase 4-Wire
—
SDO4●●●
SDG4●●●
SDW12●●●
SDA2●●●
2
45
3
90
—
SEO4●●●
SEG4●●●
SEW12●●●
SEA2●●●
4
135
—
SFO4●●●
SFG4●●●
SFW12●●●
SFA2●●●
100 100
Auxiliary Units
Table 16.162 shows the maximum number of auxiliary units (in addition to the holding circuit and interlocking contacts) that can be added to either the forward or reverse contactor or starter. Table 16.162: Auxiliary Units—Class 8702, 8736, and 8810 NEMASize (Type) No. of Poles— Basic Contactor Maximum number of auxiliary units on each contactor, forward or reverse (in addition to internal holding circuit and interlocking contacts) 00 (SA) 2–3 2 single circuit auxiliary contacts (N.O. or N.C.) 0–2 (SB–SD) 2–3 4 single circuit auxiliary contacts (N.O. or N.C.) [7] 4 2 single circuit auxiliary contacts (N.O. or N.C.) 3–6 (SE–SJ) Any 2 single circuit auxiliary contacts (N.O. or N.C.)
Dimensions: page 16-65 Factory Modifications (Forms): page 16-117 Separate Enclosures (Class 9991): page 16-111 Replacement Parts (Class 9998): page 16-123 Type S Accessories (Class 9999): page 16-127 For How to Order Information, see page 16-28.
[6] NEMA 12 enclosures can be field modified for outdoor non-corrosive and non–service entrance rated applications. See General Information , page for more information. [7] When adding 4 external auxiliary contacts to one Size 0 or 1 contactor, remove one of the return springs.