Square D Digest 179
Contactors, Type S
Type S Reversing Full Voltage Contactors and Starters
www.se.com/us
Class 8702 / Refer to Catalog 8502CT9701
General Information
Class 8702 Type S reversing magnetic contactors are used for starting, stopping, and reversing AC motors where overload protection is separately provided. Class 8702 reversing contactors consist of two Class 8502 contactors mechanically and electrically interlocked. Open type devices, Sizes 0–5, are available in either horizontal or vertical arrangements. Sizes 00 and 6 are available as horizontal only. Enclosed devices, Size 00–6, use horizontally arranged components. Type S reversing contactors are designed for operation at up to 600 Vac, 50/60 Hz. NOTE: In Table 16.159, replace the three bullets (●●●) in the catalog number with the coil voltage code. Refer to the standard coil voltage codes listed in Table 16.160. For information on field modification of NEMA 12 enclosures, see page 16-113 .
NEMA 00, 0, and 1 Reversing Contactor
Table 16.159: 600 Vac Maximum—50–60 Hz
NEMA 12/3R [3] Dusttight & Driptight Industrial Use Enclosure
NEMA 4X Watertight, Dusttight Brushed Stainless Steel Enclosure (Sizes 0–5) [1] [2]
NEMA1 General Purpose Enclosure
OpenType
Continuous Current Ratings
Motor Voltage
Max. Hp
NEMASize
Vertical Type
Horizontal Type
Type
Type
Type
200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575
1.5 1.5
16 NEMA AND DEFINITE PURPOSE CONTACTORS AND STARTERS
00
9
—
SAO4●●●
SAG4●●●
UseSize0
UseSize0
2 2 3 3 5 5
0
18
SBO12●●●
SBO4●●●
SBG4●●●
SBW14●●●
SBA4●●●
7.5 7.5 10 10 10 15 25 25 25 30 50 50 40 50 100 100 100 200 200 150 200 400 400 75
SCO7●●●
SCO8●●●
SCG8●●●
SCW14●●●
SCA4●●●
1
27
2
45
SDO1●●●
SDO2●●●
SDG2●●●
SDW11●●●
SDA1●●●
3
90
SEO1●●●
SEO2●●●
SEG2●●●
SEW11●●●
SEA1●●●
SFO1●●●
SFO3●●●
SFG3●●●
SFW11●●●
SFA1●●●
4
135
5
270
SGO1●●●
SGO3●●●
SGG3●●●
SGW11●●●
SGA1●●●
6
540
—
SHO1●●●
SHG1●●●
—
SHA1●●●
NOTE: For voltage codes used with control transformers, see page page 16-118. Form S (separate control) is used when a separate source of power is available for the control (coil) voltage. Form S is available at no charge. Dimensions: page 16-65 Factory Modifications (Forms) page 16-117
Table 16.160: Coil Voltage Codes Voltage
Code
60Hz 24 [4] 120 [5] 208 240 277 480 600 Specify
50Hz
— 110 — 220 —
V01 V02 V08 V03 V04 V06 V07 V99
Separate Enclosures (Class 9991): page 16-111 Replacement Parts (Class 9998): page 16-123 Type S Accessories (Class 9999): page 16-127 For How to Order Information, see page 16-28.
440 550 Specify
[1] NEMA 4X stainless steel enclosures (sizes 0–5) have a brushed finish. [2] NEMA 4X stainless steel enclosures are shipped with hubs installed in the top and bottom of the enclosure. [3] NEMA 12 enclosures can be field modified for outdoor non-corrosive and non-service entrance rated applications. See Enclosures—Reversing, page for more information. [4] 24 V coils are not available on Sizes 4-6. On Sizes 00-3, where 24 V coils are available, FormS (separate control) can be specified (i.e., order as 8702SAO4V01S). [5] This voltage code can include FormS for separate control (provided at no charge) (for example, order as 8702SAO4V02S).
16-61
© 2024 Schneider Electric All Rights Reserved