Square D Digest 179
Combination Service Entrance Devices (CSEDs)
Dimensions for CSEDs
1 LOAD CENTERS 14.97 380
Class 4119, 4120
www.se.com/us
Dimensions for CSEDs Table 1.86: Knockouts Symbol A B
28.28 718
C
D
E
F 2
G H
I
J
“A” Hub
B,C,D
Conduit Size (in.)
C,D,F
A
1/2 4 ▲ Driphood supplied factory-installed and is required for surface mount installation. For semi-flush installation, remove driphood and install flange kit SC200F (order separately). ■ Unit supplied with blank top endwall (factory-installed) for surface mount installation. For semi-flush installation, install flange kit FK400 (order separately). Kit includes replacement top endwall (with knockouts) and flanges. ♦ Unit supplied with semi-flush top endwall factory installed and semi-flush flanges factory included. 3/4 1 1-1/4 1-1/2 2-1/2 3 3-1/2
7.14 181
7.50 191
Drip Hood
Semi-Flush End Wall
“A” Hub
“B” Hub
2 1 / 2 " Max “A” Hub
4.60 117
4.60 117
4.56 116
7.50 191
Blank End Wall
19.58 497
13.46 342
28.25 718
13.82 351
6.44 164
8.00 203
10.70 272
7.44 189
12.80 325
18.23 463
20.79 528
A,B
C,D,E,F
41.25 1048 OBS
E,F,G,H
A,B
C,D,E,F
B,C A
OBS
C125RB (Shown) CQRB100
Ringless Type: RC200S
D,F,G
A,B
Ring Type: CM200S C2M200S (Shown) C4L200S OBS
SO1020M100S
RC2M200S RC2M200S
OBS
H
2 1 / 2 " Max “A” Hub
OBS
A
G,H,I,J “A-L” Hub
2 1 / 2 " Max “A” Hub
5.32 135
2 1 / 2 " Max “A” Hub
A,B
C,D,F
B,C
A
4.67 119
18.35 466
C,D,F
B,C
4.80 122
Lever ByPass Devices
3.39 86
CU12L400CN c CU12L400CB c QU12L400CL c QU12L400SL CU12L400FN f CU12L400FB f CU816D400FN f CU816D400FB f QU816D400CK QU12L400FL f QU816D400FL f
CU816D400CB c CU816D400CN c QU816D400CL c QU816D400SL (Shown)
Surface
14.37 365
14.77 375
10.94 278
12.57 319
14.50 368
10.04 255
2 1 / 2 " Max “A” Hub D,F,G
10.87 276
B,C
C,D,F
OBS
10.87 276
c
40.93 1040
48.62 1235
6.95 176
25.12 638
35.13 892
25.12 638
14.50 368
Lever ByPass Devices
A
14.81 376
2 1 / 2 " Max “A” Hub D,F,G
A,B B,C
A
A,B B,C
D,F,G 2 1 / 2 " Max “A” Hub or B300
A,B,C A,B
E,F,G,H
A,B,C A,B
C,D,F
D,E,F,G
32.23 819
SC8L125S (Shown) RC8L125S OBS SC1624M100S SC1624M125S RC1624M100S RC1624M125S OBS
C,D,E,F SC8L125F OBS (Shown)
RC816F100SH RC816F125SH OBS RC816F150SL OBS RC816F200SL OBS RC816F150S OBS ,SH OBS RC816F200S OBS ,SH OBS RC12L200S OBS RC2040M125SH OBS RC2040M150SH RC2040M200S, SH OBS
QC816F100SH OBS QC816F125SH OBS QC816F150S, SH OBS (Shown)
C,D,E,F
QC12L200C OBS QC816F100CH QC816F150C QC816F200CH RC12L200C RC816F100CH RC816F125CH RC816F150C RC816F150CH QC816F125C QC816F200C
C,D,E,F
SC1624M100F SC1624M125F
RC816F200C RC816F200CH RC2040M125CH OBS RC2040M150CH RC2040M200C RC2040M200CH QC2442M200C QC2442M200CH OBS
QC816F150SL OBS QC816F200SL OBS
QC816F200S OBS ,SH OBS QC12L200S OBS QC2442M200SH SO2040M200S QC3040M200SH OBS
A,B C,D,E,F
B,C
A
A
C,E,F,G,H 2 1 / 2 " Max “A-L” Hub
A,B
3.40 86
A
C,D,F A,B
RC3040M150SL RC3040M200SL
B,C
C,D,E,F
B,C
14.85 377
14.62 371
7.90 201
SU816D150C q SU816D200C q SU2040M200C q RC816D200CH SC816D150C SC816D200C q q
OBS OBS
7.50 191
Blank End Wall
OBS
28.25 718
q
CL Top Branch Circuit Breaker
(Shown)
8.00 203
2 1 / 2 " Max “A” Hub
39.60 1006
31.61 803
35.40 899
27.00 686
5.80 147
21.50 546
48.00 1219
41.25 1048
10.30 262
11.10 282
CL Meter Socket
29.50 749
B,C
B
SC3040M200S
32.30 820
C,E,F,G,H 2 1 / 2 " Max “A-L” Hub
A
37.30 947
SC40M200S
A
4.40 112
G,H,I,J “A-L” Hub
A
C,D,E,F
B,C B
SC816F200F OBS SC2040M125F OBS SC2040M200F OBS (Shown)
“A” Hub or B300 Hub
B
3.50 89
35.40 899
C,D,F
B,C
A
C,D,E,F
D,F,G
C,D
B
SU3040D400CB c (Shown) RU3040D400CL c RU3040D400CK OBS c
SC3040M200F OBS SC3040M225PF OBS SC2636M200FPV OBS SC2636M225FPV OBS
SU3040D300CB OBS c SU3040D400CN c RU3040D400FL f RU3040D400FK OBS f
C,E,F,G,H 2 1 / 2 " Max “A-L” Hub
B,C
SU3040M200R OBS (Shown) SU3040M225R OBS
39.60 1006
SU3040D300FB f SU3040D400FB f SU3040D400FN f
B
SC40M200S OBS SC2040M200S OBS (Shown) SC3040M200S OBS
CUM400CB QUM400CL QUM400CK OBS c c c
SC12L200S SC816F150S OBS SC816F200S OBS
OBS This product is obsolete.
1-44
© 2024 Schneider Electric All Rights Reserved
Made with FlippingBook Ebook Creator