Square D Digest 179

Rainproof, Meter Mains and All-In-Ones, 300–400A

Combination Service Entrance Devices (CSEDs)

Class 4119, 4120

www.se.com/us

Table 1.84 Meter Mains (cont'd.)

Load Center and Branch Circuit Breakers (Order separately [60] )

(Order separately [61] ) Line Side Main Lugs AWG/ kcmil (Al/Cu)

Serv ice Grou nd Lug AWG/ kcmil

Service (Type of Feed)

Weig ht Each (Lbs) and Pallet Qty.

Service Disconnect(s) [59]

Max. Quantity

Bus Rating

Cat.No.

1P

2P Cir cuits (Max.)

UL and EU SERC

Type (Order separately [62] )

Ampere Rating (Max.)

Cir cuits

Tan dems

(Al/ Cu)

UL

Ampere Rating

Bypass Type

Short Circuit

Current Rating

Spaces

Ampere

Rating Max.

HubType

Class 320 Lever

QDL22200 [65]

4–600 (2) 1/0–350

1

RC816D400SL [63] [64]

OH/ UG — 25kA

77, 4

400A

200A 8 16

8 200A A–L

200 12–2/ 0

1 QDL, QGL, QJL [66]

1 LOAD CENTERS

OBS This product is obsolete.

Table 1.85: All-in-One Combination Service Entrance Devices Surface and Semiflush Mount [59] Ring Type, Homeline

SU3040D300CB OBS [67][68][69] SU3040D300FB [67] [68][69] SU3040D400CN [67] [68] SU3040D400FN [67] [68] SU3040D400CB [67] [68][69] SU3040D400FB [67] [68][69] RU3040D400CL [68] [72][69] RU3040D400FL [68] [72][69] RU3040D400CK OBS [68][69] RU3040D400FK OBS

1

Class 320 Manual

QDL22200 [70] QDL, QGL, QJL [71]

200A 100A 30 40

300 A

200 4–250 100, 4

10 200 A A–L (2) Studs

UG — 25 kA

1

200

1

QDL22200 [70] QDL, QGL, QJL [71]

200A 200A 30 40

400 A None UG UG

25 kA

4–250 100, 4

10 200 A A–L (2) Studs

1

200

QDL22200 [70]

200A

200

1

Class 320 Manual

400 A

UG — 25 kA

30 40

10 200 A A–L (2) Studs

4–250 100, 4

1 QDL, QGL, QJL [71]

200A

200

Ringless, Homeline

QDL22200 [70]

1

200A

Class 320 Lever

400 A

UG — 25 kA

200 4–250 100, 4

30 40

10 200 A A–L (2) Studs

1 QDL, QGL, QJL [71]

200A

1 1

QDL22200 [70] QDL, QGL, QJL [71]

— —

200A 200A 30 40

400 A

K-4 Bolt-on UG —

25 kA

10 200 A A–L (2) Studs

4–250 100, 4

OBS This product is obsolete.

[59] UL short circuit current rating is equal to the lowest interrupting rating of any circuit breaker installed. [60] To order branch circuit breakers, see QO Plug-On Circuit Breakers, page 1-3 [61] To order hubs, see Accessories and Hubs for CSEDs, page 1-47 [62] To order service disconnects, see Circuit Breakers for CSEDs, page 1-46 except as noted) [63] Supplied with load side feed-thru lugs for 6 AWG–250 kcmil (Al/Cu) conductors. [64] Fifth jaw factory-installed. [65] Service disconnect supplied factory-installed. [66] Additional service disconnect for field-installation: order prefix QBL at 10 kA, QDL at 25 kA, QGL at 65 kA, or QJL at 100 kA. Order separately. For complete circuit breaker catalog number, see Digest Section 7. [67] For use only on 120/240 Vac 1Ø3W system (4-jaw meter socket). [68] Knockout provided in cover for use with barrel lock kit SCBRLLOCK (see Accessories). [69] Device configuration is not included in EUSERC standards. Consult applicable utility for acceptance. [70] Service disconnect supplied factory-installed. [71] Additional service disconnect for field-installation: order prefix QBL at 10 kA, QDL at 25 kA, QGL at 65 kA, or QJL at 100 kA. Order separately. For complete circuit breaker catalog number, see Digest Section 7. [72] 5th jaw factory-installed.

1-43