Rainproof, Meter Mains

Combination Service Entrance Devices (CSEDs)

www.se.com/us Class 4119, 4120 Table 1.81 Rainproof Meter Mains (cont'd.)

Load Center and Branch Circuit Breakers (Order separately [16] )

Hub Type (Order separately [17] ) Line Side Main Lugs AWG/ kcmil (Al/Cu)

Service Disconnect(s)

Weight Each (Lbs) and Pallet Qty.

Service Ground Lug| AWG/| kcmil| (Al/Cu)

Service (Type of Feed)

Bus Rat ing

Max. Quantity

Cat.No.

2P Cir cuits (Max.)

Type (Order separately [18] )

1P

Ampere Rating ULand EU SERC 200 A None OH/UG — 10 kA RC12L200S OBS Bypass Type Short Circuit Current Rating UL

Cir cuits

Tan dems

Ampere 200A [19]

Rating Max.

Spaces

Ampere

Rating Max.

6

HOM

— — — — A 6–350 8–2/0

— 43, 21

200A [19]

200 A None OH/UG — 22 kA RC12L200C [20]

6

HOM

— — — — A 6–350 12-2/0 200 40, 21

1 LOAD CENTERS

Surface Mount Only, Supplied with Feed-Thru Lugs and provisions for Branch Circuit Breakers 100 A Horn OH/UG — 22 kA RC816F100SH OBS [21] [20] [22] 1 QOM2100VH [23]

100A 8 16

8 100A

8–2/0

— 43, 21

RC816F125SH OBS RC816F100CH [21] [20] [22]

QOM2100VH [23] QOM2125VH [23] QOM2125VH [23] QOM2150VH [23] QOM2150VH [23] QOM2150VH [23] QOM2150VH [23] QOM2150VH [23] QOM2200VH [23] QOM2200VH [23] QOM2200VH [23] QOM2200VH [23] QOM2200VH [23]

100 A Horn OH/UG — 22 kA

100A 8 16

8 100A

12-2/0 — 40, 21

1

1

125A 8 16

8 100A

8–2/0

— 43, 21

125 A Horn OH/UG — 22 kA RC816F125SH OBS

RC816F125CH [21] [20] RC816F150S OBS [21] [20] RC816F150C [21] [20] RC816F150SH OBS [21] [20] [22] RC816F150CH [21] [20] [22] RC816F150SL OBS [20] [22] [25] RC816F200S OBS [21] [20] [22] RC816F200C [21] [20] RC816F200CH [21] [20] [22] RC816F200SL OBS [21] [20] [22] [25] RC816D200CH [27] [21] [22] [28]

125 A Horn OH/UG — 22 kA

125A 8 16

8 100A

12-2/0 200 40, 21

1

150A [24] 150A [24] 150A [24] 150A [24] 200A [19] 200A [19] 200A [19] 200A [19]

1

150A 8 16

8

8–2/0

— 43, 21

None OH/UG — 22 kA

None OH/UG — 22 kA

150A 8 16

8

12-2/0 200 40, 21

1

Horn OH/UG — 22 kA

150A 8 16

8

8–2/0

— 43, 21

150A

1

6–350

A

Horn OH/UG — 22 kA

1

150A 8 16

8

12-2/0 200 40, 21

200A 8 16

8 150A

8-2/0 200 72 / 12

Lever OH/UG — 22 kA

1

1

200A 8 16

8

8–2/0 200 43, 21

None OH/UG — 22 kA

200 [26]

40, 21

None OH/UG — 22 kA

200A 8 16

8

12-2/0

1

Horn OH/UG — 22 kA RC816F200SH OBS

200A 8 16

8

8–2/0

— 43, 21

200A

1

Horn OH/UG — 22 kA

1

200A 8 16

8

12-2/0 200 40, 21

200A 8 16

8 200A

8-2/0 200 72 / 12

Lever OH/UG — 22 kA

1

1 HOM2200 [23] 200A

200 48, 18

100A [29]

200 A Horn OH/UG — 10 kA

8 16

8

6–300 6–1/0

1

HOM 50A

OBS This product is obsolete.

[16] To order branch circuit breakers, see QO Plug-On Circuit Breakers, page 1-3 [17] To order hubs, see Accessories and Hubs for CSEDs, page 1-47 [18] To order service disconnects, see Circuit Breakers for CSEDs, page 1-46 except as noted) [19] Use only 15–100 A and 150–200 A circuit breakers. [20] Device supplied with barrel lock provisions factory-installed. [21] Supplied with load side feed-thru lugs, for 4 AWG–250 kcmil (Al/Cu) conductors. [22] 5th jaw factory-installed.

[23] Service disconnect supplied factory-installed. [24] Use only 15–100 A and 150 A circuit breakers. [25] Suitable for load wires to exit top endwall with addition of Tunnel Kit OHBL, see Table 1.89 Accessories, page 1-47, check with local utility for approval. [26] Not solar ready. [27] Convertible to semiflush with SC200F flange kit (order separately). [28] Knockout provided in cover for use with barrel lock kit SCBRLLOCK (see Accessories). [29] A 100 A circuit breaker can be installed in bottom position only, all other positions are limited to 70 A max.

1-39