Square D Digest 179
Combination Service Entrance Devices (CSEDs)
Rainproof, Meter Mains
1 LOAD CENTERS
Class 4119, 4120
www.se.com/us
Rainproof Meter Mains
Table 1.81: Rainproof Meter Mains
Load Center and Branch Circuit Breakers (Order separately [1] )
Line Side Main Lugs
Service Disconnect(s)
Weight Each (Lbs) and Pallet Qty.
Service Ground Lug| AWG/| kcmil| (Al/Cu)
Service (Type of Feed)
Hub Type (Order separately [2] ) AWG/ kcmil (Al/Cu)
Bus Rat ing
Max. Quantity
Cat. No.
2P Cir cuits (Max.)
Type (Order separately [3] )
1P
ULand EU SERC
Cir cuits
Tan dems
UL
Ampere Rating Ring Type, QO TM Surface Mount Only 125 A None OH/UG — 10 kA Bypass Type
Short Circuit
Current Rating
Ampere
Rating Max.
Spaces
Ampere
Rating Max.
QOM1-VH 125 A — — — — B 4–1/0 8–1/0
C125RB CM200S
1
— 15, 54
1 QOM2-VH 200 A — — — — A 4–250 (2)8–2/0 — 26, 24
OH/UG — 22 kA
—
QOM2-VH QO-VH
200A 50A
— —
— —
— —
— — A 4–250
1 1 2
(2)8–2/0 — 27, 20
200A None
OH/UG 22 kA C2M200S OBS — OH/UG — 10 kA C4L200S OBS
QO 100 A — — — — A 4–250 (2)8–2/0 — 27, 28
Ring Type, Homeline TM Surface Mount Only 125 A None OH/UG OH/UG 10 kA
125 A — — — — A 6–2/0 6–2/0 125 — — — — A–L 4–250 8–2/0 200 40, 10 31, 24
SC8L125S
4
HOM
200A [4]
6
HOM
200 A None OH/UG OH/UG 10 kA SC12L200S OBS Semiflush Mount only 125 A None OH/UG OH/UG 10 kA SC8L125F OBS
— 37, 20
4
HOM 110A — — — — Aor
B300 6–2/0 6–2/0
OH [5] /UG
200A [6]
OH [5] / UG 10 kA SC12L200F
200A None
6
HOM
— — — — A–L 4–250 8–2/0 225 47, 10
OBS
Surface Mount—Supplied with Feed-Thru Lugs and provisions for Branch Circuit Breakers
SC816D150C [7] [8] SU816D150C [7] [8] OBS SC816D200C [7] [8] SU816D200C OBS
200
—
1 1 1 1 1 1 1 1 1 1 6
100A [10] 100A [10]
HOM2150 [9] HOM HOM2200 [9]
150A 50A 8 16 200A 50A 8 16
AorA– L AorA– L
48, 18
8
6–300 8–1/0
150 A None OH/UG
10kA
UG
—
200
—
48, 18
200 A None UG Ringless, QO TM Surface Mount Only
10kA
8
6–300 8–1/0
UG
HOM
—
RC200S [11]
QOM2-VH 200 A QOM2-VH 200 A
None Lever None Horn Lever
22kA
A 6–350 (2)8–2/0 — 26, 24
10 kA RCM200SL [11] [12]
A 6–350 8-1/0
— 60 / 14
RC2M200S [11]
A 6–350 (2)8–2/0 — 27, 20 A 6–350 (2)8–2/0 — 27, 20
QOM2-VH QO-VH
200A 50A
22kA
RC2M200SH OBS [11] RC2M200SL OBS [11] [12] QC12L200S OBS [11] [12]
QOM2-VH 200 A QO-VH 50A QO-VH 200A
8-1/0 8-1/0
200A
OH/UG —
— — — —
10kA
A 6–350
— 60 / 14
None
22kA
A 6–350 8–2/0
— 43, 21
200A [6]
22 kA QC12L200C OBS [11]
QO-VH
None
6
A 6–350 12-2/0 200 40, 21
Surface Mount Only, Supplied with Feed-Thru Lugs and provisions for Branch Circuit Breakers 100 A Horn OH/UG — 22 kA QC816F100CH [7] [11] [12] 1 QOM2100VH [9]
100A 8 16
8
100
A 6–350 12-2/0 200 40, 21
QOM2125VH [9] QOM2125VH [9] QOM2150VH [9] QOM2150VH [9] QOM2150VH [9] QOM2200VH [9] QOM2200VH [9] QOM2200VH [9] QOM2200VH [9]
125A 8 16
8
100
A 6–350 8–2/0
— 43, 21
None OH/UG — 22 kA QC816F125S OBS
1
125A
None OH/UG — 22 kA QC816F125C [7][11]
125A 8 16
8
100
A 6–350 12-2/0 125 40, 21
1
QC816F150S [7][11] [12]
150A [13] 150A [13]
None OH/UG — 22 kA
1
150A 8 16
8
A 6–350 8–2/0 200 43, 21
None OH/UG — 22 kA QC816F150C [7][11]
150A
150A 8 16
8
1
A 6–350 12-2/0 200 40, 21
QC816F150SL OBS [7] [11] [12] QC816F200S OBS [7] [11] [12] QC816F200SH OBS [7][11] [12] QC816F200CH OBS [7] [11] QC816F200SL [7] [11] [12]
1
200A 8 16
8 150 A A 6–350 8-2/0
— 74 / 12
Lever OH/UG — 22 kA
200A [6] 200A [6] 200A [6]
None OH/UG — 22 kA
200A 8 16
8
200
1
A 6–350
43, 21
8–2/0
200A 8 16
8
Horn OH/UG — 22 kA
1
A 6–350
—
200A
1
200A 8 16
8
A 6–350 12-2/0 200 40, 21
Horn OH/UG — 22 kA
Lever OH/UG — 22 kA
200A 8 16
8 200 A A 6–350 8–2/0 200 74 / 12
1
Ringless, Homeline TM Surface Mount Only 125 A None OH/UG — 10 kA RC8L125S OBS [14]
125A [15]
4
HOM
— — — — A 6–2/0 6–2/0 125 27, 32
[1] To order branch circuit breakers, see QO Plug-On Circuit Breakers, page 1-3 [2] To order hubs, see Accessories and Hubs for CSEDs, page 1-47 [3] To order service disconnects, see Circuit Breakers for CSEDs, page 1-46 except as noted) [4] Use only 15–110 A and 150–200 A breakers. [5] Suitable for OH service with addition of tunnel kit (SCTK20). Order separately. [6] Use only 15–100 A and 150–200 A circuit breakers. [7] Supplied with load side feed-thru lugs, for 4 AWG–250 kcmil (Al/Cu) conductors. [8] Convertible to semiflush with SC200F flange kit (order separately). [9] Service disconnect supplied factory-installed. [10] A 100 A circuit breaker can be installed in bottom position only, all other positions are limited to 70 A max. [11] Device supplied with barrel lock provisions factory-installed. [12] 5th jaw factory-installed. [13] Use only 15–100 A and 150 A circuit breakers. [14] Knockout provided in cover for use with barrel lock kit SCBRLLOCK (see Accessories). [15] 125 A Homeline™ 2P circuit breaker can be installed in top position only. All other positions are limited to 100 A max.
1-38
© 2024 Schneider Electric All Rights Reserved