Modicon M580 automation platform Modicon M580 Safety redundant processors

Selection guide (continued)

Modicon M580 automation platform

BMEH582040S + BMEP58CPROS3 mandatory coprocessor (1)

BMEH584040S + BMEP58CPROS3 mandatory coprocessor (1)

BMEH586040S + BMEP58CPROS3 mandatory coprocessor (1)

1

1

+

+

+

2

2

Racks

Local racks (main + extension)

1 8

16

31

Remote I/O drops (2) Discrete I/O channels

Local X80 I/O (3) (4)

Safe discrete I/O channels Analog I/O channels Safe analog I/O channels Application-specific channels (5)

Not supported

3

3

Combined Local and Remote X80 I/O (4)

16384

31744 11408

Discrete I/O channels

8192 2944 2048

5888 4096 1088

Safe discrete I/O channels

7936 2108 1116

Analog I/O channels

Safe analog I/O channels

544 288

4

4

576

Application-specific channels (5)

Distributed equipment (DIO, CSIO)

EtherNet/IP or Modbus TCP devices (scanned by CPU)

61

436

436

EtherNet/IP or Modbus TCP devices (scanned by CPU and Ethernet modules)

BMENOC301/ BMENOC311

317

CIP safety devices (scanned by CPU)

– (9)

Integrated communication ports

Ethernet service port (RJ45)

Engineering and Maintenance console (EcoStruxure Control Expert, Web browser, external tools), HMI, SCADA, Distributed equipment (DIO)

Ethernet device network dual ports (RJ45) - RSTP

RIO network (RIO/DIO scanner)

5

5

USB type mini B port

Programming port for Engineering Console (EcoStruxure Control Expert)

Communication

Ethernet networks

Cumulative max number of Ethernet networks modules

BMENOC/BMENOP/ BMENOR

2

4

EtherNet/IP and Modbus TCP

EtherNet/IP and Modbus TCP module BMENOC0301

2 2 2 2 2 2

3 3

FactoryCast IP Forwarding

FactoryCast module Ethernet control router

BMENOC0311 BMENOC0321 BMENOP0300 BMENUA0100

IEC 61850

IEC 61850 module OPC UA module

3

6

6

OPC UA

DNP3 NET / IEC 60870-5-104 DNP3 Serial / IEC 60870-5-101

Advanced RTU module

BMENOR2200H (6) BMXNOR0200H

4

RTU module

– (7) – (9) 4 (8)

Global Data AS-Interface

Global Data module AS-Interface module Serial link module CANopen module PROFIBUS DP module Program process (MB)

BMXNGD0100 BMXEIA0100 BMXNOM0200 BMECXM0100 PMEPXM0100

8 (8)

Each BMXNOM0200 channel counts as an application-specific channel (10)

Serial Link (Modbus and Character)

7

7

– (9)

CANopen

PROFIBUS DP

2 8 2

6

10 64 16

Internal memory capacity

16

Program safe (MB) Data process (KB)

4

768 512

2048 1024

Up to 64MB (11)

Data safe (KB)

1024

8

8

Data storage (GB)

4

40 30

50 40

No. of K instructions executed per ms

100% Boolean (Kinstr/ms)

10

65% Boolean + 35% fixed arithmetic (Kinstr/ms)

7.5 No

Product compatibility with Quantum

Support of Quantum Ethernet I/O (QEIO) and LL984 Editor

Yes

References

BMEH582040S

BMEH584040S

BMEH586040S

Pages

3/13

(1) The mandatory coprocessor must be ordered separately. (2) A Remote I/O drop can be either a X80 RIO Drop (RIO) or Quantum Ethernet I/O drop (QEIO). One X80 RIO Drop can support up to 2 racks (via X-bus extension). (3) Local X80 I/O are localized in local racks (main or extension). Redundant controllers do not not support Local X80 IO. (4) Maximum number of I/O channels (Discrete, Safe Discrete, Analog and Safe Analog) as well as application-specific channels is not cumulative. (5) Application-specific channels include counters, time-stamping, SSI encoder, Motion control, Serial and Frequency input modules. (6) Maximum number of BMENOR modules is not cumulative with other Ethernet network modules. (7) Not supported with safety controllers. (8) Only supported in Remote I/O drops : 2 per drop and with a maximum of 16 BMXEIA0100 modules. (9) Not supported with safety redundant controllers. (10) Only supported in Remote I/O drops. (11) BMEH586040S CPU features a global memory pool of 64 Mbytes for Program process (non-safe), Data process (non-safe non-retain data only), Program safe, and Data safe.