SE Digest 178
Class 9012 and 9016 Electrical Ratings and Dimensions
Pressure Switches and Vacuum Switches
Refer to Catalog 9012CT9701
www.se.com/us
Electrical Ratings
Table 22.55: Control Duty Circuit Ratings
AC—50 or 60 Hz
DC
ACorDC
Inductive, 35% Power Factor
Inductive and Resistive Make and Break Amperes
Resistive 75% Power Factor
Con tacts
Continuous Carrying Amperes
Make
Break
V
V
Make and Break Amperes
Single Throw
Double Throw
A
VA
A
VA 720 720 720 720 720 720 720 720
120 60 240 30 480 15 600 12 120 60 240 30 480 15 600 12
7200 7200 7200 7200 7200 7200 7200 7200
6 3
6 3
120 0.55 250 0.27 600 0.10 — — 125 0.22 250 0.11 600 — — —
0.22 0.11
10 10 10 — 10 10 10 —
SWITCHES
SPDT
1.5 1.2
1.5 1.2
— —
6 3
6 3
0.22 0.11
DPDT
1.5 1.2
1.5 1.2
— —
22 PRESSURE, VACUUM, AND FLOAT
Table 22.57: Type G Industrial Contact Arrangement
Table 22.56: Type G Machine Tool and Vacuum (except GVG) Type Contact Arrangement Contact Symbol
Contact Symbol
1 N.O. – 1 N.C. (600 Vdc rating does not apply)
1
3
Same Polarity
Single Pole Double Throw
1 N.O.–1 N.C.
NOTE: Contacts are single pole, double throw—one circuit normally open and one circuit normally closed. These circuits are not electrically separate and can not be used on opposite polarities. Table 22.58: Temperature Ratings Actuator Minimum Maximum Ambient All -23 °C (-10 °F) +85 °C (+185 °F)
2
4
NOTE: Snap switch contains two double-break contact elements (1 N. O. and 1 N.C.) that must be used on circuits of same polarity.
Contact Arrangement
Contact Symbol
Type
Polarity
Diaphragm
-40 °C (-40 °F)
Same
Double Pole Double Throw
2 N.O.–2 N.C.
Piston -26 °C (-15 °F) All with Forms Q4 and Q14 -26 °C (-15 °F)
+120 °C (+250 °F)
Media
Same Polarity
NOTE: Snap switch contains two electrically separated sets of contact elements allowing use on circuits of opposite polarity. Each set contains two double break contact elements (1 N.O. and 1 N.C.) that must be used on circuits of the same polarity.
Types GAW, GBW, GCW, GDW, GEW, GFW, GKW, GLW, and GMW Machine Tool Switches (except 1, 21)
Types GAW, GDW, GKW 1, 21
3.50 89
Form K
1.13 29
2.63 67
0.88 22
2.72 69
0.48 12
0.38 10
2.30 58
0.40 10
0.48 12
Form K1
0.17 4
X : Conduit connection: G•W = 1/2-14 NPT; G•WM = 20MMBGS4568, Form M12 = Pg13.5; DIN40430. Y : Pressure connection: G•W = 1/4-18 NPTF; G•WM = 8; Form M14 = G 1/4 BS 2779; RP1/4 ISO 711; R 1/4 DIN 2999; GJ 1/4 UN1339.
Forms E1, E2, E3, E4
3.60 91
0.27 7 (2) dia. Mtg. Holes
2.72 69
Forms G17, G18, G21, G22, G23
0.38 10
A
1/2-14 NPT Conduit Electrical Connection
1/4-18 NPTF Pipe Thread Pressure Connection
1.22 31
0.58 15
1.61 41
in. mm
Dual Dimensions:
Table 22.59: Dimension A for G•W Switches Type GAW, GDW, GKW 2, 4, 5, 6 22, 24, 25, 26, 52, 54, 55, 56
Dimension A, in. (mm)
2.33 (59) 2.23 (57) 3.15 (80)
GBW, GEW, GLW 1, 2, 21, 22, 51, 52
GCW, GFW, GMW 1, 2, 3, 4 21, 22, 23, 24, 51, 52, 53, 54
Types GAR, GBR, GCR, GDR, GER, and GFR
Table 22.60: Dimension A for G•R, Switches Type / Tipo / Type
Dimension A, in. (mm)
in. mm
4.95 126
Dim. =
Cover Removal Clearance
2.02 (51.3) 1.42 (36.1) 1.32 (33.5) 2.24 (56.9) 2.02 (51.3) 1.42 (36.1) 1.32 (33.5) 2.24 (56.9)
GAR1, 2, 21, 22
GAR4, 5, 6, 24, 25, 26
GBR1, 2, 21, 22; GCR1, 21
GCR2, 3, 4, 22, 23, 24
5.78 147
GDR1, 2, 21, 22
GDR4, 5, 6, 24, 25, 26
0.44 11.2
∅
GER1, 2, 21, 22; GFR1, 21
GFR2, 3, 4, 22, 23, 24
3/4-14 NPT
A
0.41 10
3.69 94
2.34 59
2.91 74
5.88 149
4.90 125
Turn Radius
22-19
© 2019 Schneider Electric All Rights Reserved
8/17/2020
Made with FlippingBook flipbook maker