SE Digest 178

Class 9012 and 9016 Electrical Ratings and Dimensions

Pressure Switches and Vacuum Switches

Refer to Catalog 9012CT9701

www.se.com/us

Electrical Ratings

Table 22.55: Control Duty Circuit Ratings

AC—50 or 60 Hz

DC

ACorDC

Inductive, 35% Power Factor

Inductive and Resistive Make and Break Amperes

Resistive 75% Power Factor

Con tacts

Continuous Carrying Amperes

Make

Break

V

V

Make and Break Amperes

Single Throw

Double Throw

A

VA

A

VA 720 720 720 720 720 720 720 720

120 60 240 30 480 15 600 12 120 60 240 30 480 15 600 12

7200 7200 7200 7200 7200 7200 7200 7200

6 3

6 3

120 0.55 250 0.27 600 0.10 — — 125 0.22 250 0.11 600 — — —

0.22 0.11

10 10 10 — 10 10 10 —

SWITCHES

SPDT

1.5 1.2

1.5 1.2

— —

6 3

6 3

0.22 0.11

DPDT

1.5 1.2

1.5 1.2

— —

22 PRESSURE, VACUUM, AND FLOAT

Table 22.57: Type G Industrial Contact Arrangement

Table 22.56: Type G Machine Tool and Vacuum (except GVG) Type Contact Arrangement Contact Symbol

Contact Symbol

1 N.O. – 1 N.C. (600 Vdc rating does not apply)

1

3

Same Polarity

Single Pole Double Throw

1 N.O.–1 N.C.

NOTE: Contacts are single pole, double throw—one circuit normally open and one circuit normally closed. These circuits are not electrically separate and can not be used on opposite polarities. Table 22.58: Temperature Ratings Actuator Minimum Maximum Ambient All -23 °C (-10 °F) +85 °C (+185 °F)

2

4

NOTE: Snap switch contains two double-break contact elements (1 N. O. and 1 N.C.) that must be used on circuits of same polarity.

Contact Arrangement

Contact Symbol

Type

Polarity

Diaphragm

-40 °C (-40 °F)

Same

Double Pole Double Throw

2 N.O.–2 N.C.

Piston -26 °C (-15 °F) All with Forms Q4 and Q14 -26 °C (-15 °F)

+120 °C (+250 °F)

Media

Same Polarity

NOTE: Snap switch contains two electrically separated sets of contact elements allowing use on circuits of opposite polarity. Each set contains two double break contact elements (1 N.O. and 1 N.C.) that must be used on circuits of the same polarity.

Types GAW, GBW, GCW, GDW, GEW, GFW, GKW, GLW, and GMW Machine Tool Switches (except 1, 21)

Types GAW, GDW, GKW 1, 21

3.50 89

Form K

1.13 29

2.63 67

0.88 22

2.72 69

0.48 12

0.38 10

2.30 58

0.40 10

0.48 12

Form K1

0.17 4

X : Conduit connection: G•W = 1/2-14 NPT; G•WM = 20MMBGS4568, Form M12 = Pg13.5; DIN40430. Y : Pressure connection: G•W = 1/4-18 NPTF; G•WM = 8; Form M14 = G 1/4 BS 2779; RP1/4 ISO 711; R 1/4 DIN 2999; GJ 1/4 UN1339.

Forms E1, E2, E3, E4

3.60 91

0.27 7 (2) dia. Mtg. Holes

2.72 69

Forms G17, G18, G21, G22, G23

0.38 10

A

1/2-14 NPT Conduit Electrical Connection

1/4-18 NPTF Pipe Thread Pressure Connection

1.22 31

0.58 15

1.61 41

in. mm

Dual Dimensions:

Table 22.59: Dimension A for G•W Switches Type GAW, GDW, GKW 2, 4, 5, 6 22, 24, 25, 26, 52, 54, 55, 56

Dimension A, in. (mm)

2.33 (59) 2.23 (57) 3.15 (80)

GBW, GEW, GLW 1, 2, 21, 22, 51, 52

GCW, GFW, GMW 1, 2, 3, 4 21, 22, 23, 24, 51, 52, 53, 54

Types GAR, GBR, GCR, GDR, GER, and GFR

Table 22.60: Dimension A for G•R, Switches Type / Tipo / Type

Dimension A, in. (mm)

in. mm

4.95 126

Dim. =

Cover Removal Clearance

2.02 (51.3) 1.42 (36.1) 1.32 (33.5) 2.24 (56.9) 2.02 (51.3) 1.42 (36.1) 1.32 (33.5) 2.24 (56.9)

GAR1, 2, 21, 22

GAR4, 5, 6, 24, 25, 26

GBR1, 2, 21, 22; GCR1, 21

GCR2, 3, 4, 22, 23, 24

5.78 147

GDR1, 2, 21, 22

GDR4, 5, 6, 24, 25, 26

0.44 11.2

GER1, 2, 21, 22; GFR1, 21

GFR2, 3, 4, 22, 23, 24

3/4-14 NPT

A

0.41 10

3.69 94

2.34 59

2.91 74

5.88 149

4.90 125

Turn Radius

22-19

© 2019 Schneider Electric All Rights Reserved

8/17/2020

Made with FlippingBook flipbook maker