SE Digest 178

Product Panorama Refer to Catalog 9006CT1007

Limit Switches

www.se.com/us

Product Panorama 1 of 2 Refer to Catalog 9006CT1007

Design

Compact

Miniature

Catalog number

9007A/O

9007MS/ML

XCMN

XCMD

XCKP

XCKD

XCKL

Precabled, Non-Modular, page21-14

Industrial Snap Switches, page 21-6

Precabled, Modular, page21-14

General Duty, page21-28

Heavy Duty, page 21-8

Page

Plastic, page 21-14

Metal, page 21-14

Metal body, metal head Bottom or side cable entry. Full range of operating heads. See page 21-8.

Plastic, double insulated

Plastic, double insulated

Open, plastic

Enclosure

Metal

Metal

Metal

A variety of operators are available.

Mounting by the body or by the head

1 conduit entry

Features

Head, body, and lever

Modularity

Selected operators

Operator

Head, body, lever, and connector

Conforming to standards Body dimensions (w x h x d), mm (in.)

CENELEC: EN 50047 31x65x30 (1.22 x 2.56 x 1.18)

29.0 x 63.5 x 21.0 (1.14 x 2.5 x 0.83)

40.1 x 44.4 x 15.8 (1.58 x 1.75 x 0.62)

30x50x16 (1.18 x 1.97 x 0.63)

52x72x30 (2.05 x 2.83 x 1.18) Linear movement, plunger. Rotary movement, lever. Rotary movement, multi-directional. [1]

Linear movement, plunger Rotary movement, lever Rotary movement, multi-directional [1] Same heads for ranges XCMD, XCKD, XCKP and XCKT

Linear or rotary

Head

Linear

Contact blocks 2 snap action contacts

N.C. + N.O.; N.C. +N.C. N.C. + N.O.; N.C. +N.C.

N.C. + N.O.; N.C. +N.C. N.C. + N.O.; N.C. +N.C.

N.C. + N.O.; N.C. +N.C. N.C. + N.O.; N.C. +N.C.

N.C. +N.O.

N.C. +N.O.

2 snap action contacts —

N.C. +N.O.

N.C. +N.O.

3 snap action contacts

N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O.

N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O.

N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O.

N.C. + N.C. + N.O.

3 snap action contacts —

N.C. + N.C. + N.O.

4 snap action contacts

N.C. + N.C. + N.O. + N.O. N.C. + N.C. + N.O. + N.O.

4 snap action contacts —

2 slow break contacts break before make 2 slow break contacts break before make 2 slow break contacts make before break 2 slow break contacts make before break 2 slow break contacts 2 slow break contacts simultaneous 3 slow break contacts break before make 3 slow break contacts break before make 21 LIMIT SWITCHES simultaneous

N.C. +N.O.

N.C. +N.O.

N.C. +N.O.

N.C. +N.O.

N.C. +N.O.

N.C. +N.O.

N.C. +N.O.

N.C. +N.O.

N.O. +N.C.

N.O. +N.C.

N.O. +N.C.

N.O. +N.C.

N.O. +N.C.

N.O. +N.C.

N.C. +N.C.

N.C. +N.C.

N.C. +N.C.

N.O. +N.O.

N.O. +N.O.

N.O. +N.O.

N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O.

N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O.

N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O.

N.C. + N.C. + N.O.

N.C. + N.C. + N.O.

2 snap action contacts N.C. + N.O., N.O. +N.O. 4 snap action contacts N.C. + N.C., N.O. +N.O.

N.C. +N.O.

Screw terminal: 2 contacts: 500 V / 10 A 3 contacts: 400 V / 6 A Connector: Integral M12, 5-pin: 60 V / 4 A NEMA Types 1, 2, 4, 6, 12, 13 IP66, IP67, IK06

Screw terminal: 2 contacts: 500 V / 10 A 3 contacts: 400 V / 6 A Connector: Integral M12, 4-pin: 250 V / 3 A NEMA Types 1, 2, 4, 6, 6P, 12, 13 IP66, IP67, IK04

Screw terminal: 2 contacts: 500V / 10A 3 contacts: 400V / 6A NEMA Types 1, 2, 4, 6, 6P, 12, 13 IP66, IK06

Pre-cabled 2 contacts: 400 V / 6 A 3 contacts: 400 V / 4 A 4 contacts: 400 V / 3 A NEMA Types 1, 2, 4X, 6, 12 IP66, IP67, IP68, IK06 Pre-cabled. Connector: Integral or remote M12 or remote 7/8" 16UN

Screw terminal 2 contacts: 400V / 6A

Insulation voltage (Ui) / thermal current (Ithe)

300 Vac/Vdc 10 A (standard)

See page 21-10

Enclosure rating IP = IEC enclosure rating IK = EN shock test standard

NEMA Types 1, 2, 13 IP65, IK04

NEMA Types 1, 2, 4, 6, 6P, 12, 13 IP67

None

Screw terminal: M16, M20, Pg 11, Pg 13, 1/2" NPT, or PF 1/2 Connector: Integral M12

Screw terminal or Faston ® connector

Pre-wired cable or M12 connector

Screw terminal: M20 or 1/2" NPT

Electrical connection

Pre-wired cable

[1] Flexible operators do not guarantee direct (positive) opening operation.

21-2

© 2019 Schneider Electric All Rights Reserved

11/20/2019

Made with FlippingBook flipbook maker