SE Digest 178
Product Panorama Refer to Catalog 9006CT1007
Limit Switches
www.se.com/us
Product Panorama 1 of 2 Refer to Catalog 9006CT1007
Design
Compact
Miniature
Catalog number
9007A/O
9007MS/ML
XCMN
XCMD
XCKP
XCKD
XCKL
Precabled, Non-Modular, page21-14
Industrial Snap Switches, page 21-6
Precabled, Modular, page21-14
General Duty, page21-28
Heavy Duty, page 21-8
Page
Plastic, page 21-14
Metal, page 21-14
Metal body, metal head Bottom or side cable entry. Full range of operating heads. See page 21-8.
Plastic, double insulated
Plastic, double insulated
Open, plastic
Enclosure
Metal
Metal
Metal
A variety of operators are available.
Mounting by the body or by the head
1 conduit entry
Features
Head, body, and lever
Modularity
Selected operators
Operator
Head, body, lever, and connector
—
Conforming to standards Body dimensions (w x h x d), mm (in.)
—
—
—
—
CENELEC: EN 50047 31x65x30 (1.22 x 2.56 x 1.18)
—
29.0 x 63.5 x 21.0 (1.14 x 2.5 x 0.83)
40.1 x 44.4 x 15.8 (1.58 x 1.75 x 0.62)
30x50x16 (1.18 x 1.97 x 0.63)
52x72x30 (2.05 x 2.83 x 1.18) Linear movement, plunger. Rotary movement, lever. Rotary movement, multi-directional. [1]
Linear movement, plunger Rotary movement, lever Rotary movement, multi-directional [1] Same heads for ranges XCMD, XCKD, XCKP and XCKT
Linear or rotary
Head
Linear
Contact blocks 2 snap action contacts
N.C. + N.O.; N.C. +N.C. N.C. + N.O.; N.C. +N.C.
N.C. + N.O.; N.C. +N.C. N.C. + N.O.; N.C. +N.C.
N.C. + N.O.; N.C. +N.C. N.C. + N.O.; N.C. +N.C.
—
—
N.C. +N.O.
N.C. +N.O.
2 snap action contacts —
—
N.C. +N.O.
N.C. +N.O.
3 snap action contacts
N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O.
N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O.
N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O.
—
—
—
N.C. + N.C. + N.O.
3 snap action contacts —
—
—
N.C. + N.C. + N.O.
4 snap action contacts
N.C. + N.C. + N.O. + N.O. N.C. + N.C. + N.O. + N.O.
—
—
—
—
—
—
4 snap action contacts —
—
—
—
—
—
2 slow break contacts break before make 2 slow break contacts break before make 2 slow break contacts make before break 2 slow break contacts make before break 2 slow break contacts 2 slow break contacts simultaneous 3 slow break contacts break before make 3 slow break contacts break before make 21 LIMIT SWITCHES simultaneous
—
—
—
N.C. +N.O.
N.C. +N.O.
N.C. +N.O.
N.C. +N.O.
—
—
—
N.C. +N.O.
N.C. +N.O.
N.C. +N.O.
N.C. +N.O.
—
—
—
—
N.O. +N.C.
N.O. +N.C.
N.O. +N.C.
—
—
—
—
N.O. +N.C.
N.O. +N.C.
N.O. +N.C.
—
—
—
—
N.C. +N.C.
N.C. +N.C.
N.C. +N.C.
—
—
—
—
N.O. +N.O.
N.O. +N.O.
N.O. +N.O.
N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O.
N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O.
N.C. + N.C. + N.O.; N.C. + N.O. + N.O. N.C. + N.C. + N.O.; N.C. + N.O. + N.O.
—
—
—
N.C. + N.C. + N.O.
—
—
—
N.C. + N.C. + N.O.
2 snap action contacts N.C. + N.O., N.O. +N.O. 4 snap action contacts N.C. + N.C., N.O. +N.O.
N.C. +N.O.
—
—
—
—
—
—
—
—
—
—
—
Screw terminal: 2 contacts: 500 V / 10 A 3 contacts: 400 V / 6 A Connector: Integral M12, 5-pin: 60 V / 4 A NEMA Types 1, 2, 4, 6, 12, 13 IP66, IP67, IK06
Screw terminal: 2 contacts: 500 V / 10 A 3 contacts: 400 V / 6 A Connector: Integral M12, 4-pin: 250 V / 3 A NEMA Types 1, 2, 4, 6, 6P, 12, 13 IP66, IP67, IK04
Screw terminal: 2 contacts: 500V / 10A 3 contacts: 400V / 6A NEMA Types 1, 2, 4, 6, 6P, 12, 13 IP66, IK06
Pre-cabled 2 contacts: 400 V / 6 A 3 contacts: 400 V / 4 A 4 contacts: 400 V / 3 A NEMA Types 1, 2, 4X, 6, 12 IP66, IP67, IP68, IK06 Pre-cabled. Connector: Integral or remote M12 or remote 7/8" 16UN
Screw terminal 2 contacts: 400V / 6A
Insulation voltage (Ui) / thermal current (Ithe)
300 Vac/Vdc 10 A (standard)
See page 21-10
Enclosure rating IP = IEC enclosure rating IK = EN shock test standard
NEMA Types 1, 2, 13 IP65, IK04
NEMA Types 1, 2, 4, 6, 6P, 12, 13 IP67
None
Screw terminal: M16, M20, Pg 11, Pg 13, 1/2" NPT, or PF 1/2 Connector: Integral M12
Screw terminal or Faston ® connector
Pre-wired cable or M12 connector
Screw terminal: M20 or 1/2" NPT
Electrical connection
Pre-wired cable
[1] Flexible operators do not guarantee direct (positive) opening operation.