SE Digest 178
Dimensions
TeSys™ D Non-Reversing Contactors
Refer to Catalog MKTED210011EN
www.se.com/us
TeSys™ island Load Management System Module Dimensions
Size 1 Starters: TPRST009 and TPRSS009
Size 2 Starters: TPRST025, TPRST038, TPRSS025 and
mm in.
mm in.
mm in.
101 3.97
121 4.76
121 4.76
114 4.48
115 4.53
115 4.53
50 1.96
Bus Coupler: TPRBCEIP
45 1.77
45 1.77
TPRSS038
Size 3 Starters: TPRST065, TPRST080, TPRSS065 and
Size 1 (TPRPM009) and Size 2 (TPRPM038) Power Interface
Size 3 (TPRPM080) Power Interface Module
mm in.
mm in.
mm in.
121 4.76
136 5.34
162 6.38
115 4.53
125 4.92
45 1.77
Module
TPRSS080 18 CONTACTORS AND STARTERS-IEC SIL Interface Module: TPRSM001 125 4.92 55 2.16
55 2.17
Voltage Interface Module: TPRVM001
Digital I/O Module: TPRDG4X2
Analog I/O Module: TPRAN2X1
mm in.
mm in.
mm in.
mm in.
101 3.97
101 3.97
101 3.97
101 3.97
114 4.48
114 4.48
114 4.48
114 4.48
25 .98
25 .98
25 .98
25 .98
TeSys™ D Contactors, AC and DC Coil
Table 18.117: TeSys D 9 to 38 A Contactors, AC and DC Coils LC1D09 to D18
LC1D25 to D38 (3-pole) and LC1DT20 to DT40 (4–pole)
Minimum electrical clearance
Minimum electrical clearance
1.73
44
LA4
b
b
b1
c
.39 10
c
.39 10
c1 c2 c3
c1 c2 c3
1.77
.51 13
1.77
45
45
(LAD8)
D098, D128, DT20, DT25 in. (mm)
D09 toD18 in. (mm)
D25 toD38 in. (mm)
DT32, DT40 in. (mm)
D188,D258 in. (mm) 4.13 (105) 4.13 (105)
TeSys D contactors: LC1D
3.03 (77) 3.03 (77) 3.70 (94)
3.36 (85) 3.36 (85) 3.85 (98)
3.34 (85) 3.34 (85) 3.85 (98) 4.48 (114) 5.02 (129) 7.48 (190) 3.54 (90) 3.62 (92) 3.90 (99) 4.84 (123) 4.84 (123) 5.31 (135) —
3.58 (91) 3.58 (91)
AC coil, without add-on accessories
b
DCcoil
AC coil, with LAD4BB AC coil, with LA4D*2 AC coil, with LA4DF, DT
— — — —
— — — —
4.33 (110) [1] 4.68 (119) [1] 4.96 (126) [1]
4.48 (114) [1] 4.84 (123) [1] 5.11 (130) [1]
b1
AC coil, with LA4DR, DW, DL
3.30 (84) 3.38 (86) 3.66 (93) 3.76 (95) 4.60 (117) 4.96 (126) 5.07 (129)
3.54 (90) 3.62 (92) 3.89 (99) 3.97 (101) 4.84 (123) 5.19 (132) 5.31 (135)
3.85 (98) 3.93 (100)
3.85 (98) 3.93 (100)
AC coil, without cover or add-on blocks AC coil, with cover, without add-on blocks DC coil, without cover or add-on blocks DC coil, with cover, without add-on blocks AC coil, with LADN or C (two or four contacts) DC coil, with LADN or C (two or four contacts)
c
—
—
4.21 (107) 5.15 (131) 5.15 (131) 5.62 (143)
4.21 (107) 5.15 (131) 5.15 (131) 5.62 (143)
c1
c2 AC coil, with LAD6K10
Including LAD4BB.
[1]
18-42
© 2021 Schneider Electric All Rights Reserved July 30, 2021
Made with FlippingBook flipbook maker