Combination Starter Units Class 8998 / Refer to Catalog 8998CT9701

www.se.com/us

Combination Starter Units with Fusible Switch Disconnects Model 6 NEMA-rated FVNR combination starter units listed below use fusible switches with Class R fuse clips (fuses not included). Ratings: 480 V, NEMA 12, Type 1B-D wiring, 100,000 AIR. Units include 1 N.O./1 N.C. auxiliary contacts. Units with pilot devices use 22 mm type. Units without pilot devices

include a station plate with knockouts for five 22 mm devices. Thermal units are not included with melting alloy overloads.

Table 17.5: FVNR Combination Starter Units with Fusible Switch Disconnects

Fused Separate Control

Control Transformer Start-Stop PB, Red On/Green Off Lights

HOA Red On/Green Off Lights

Start-Stop PB, Red On/Green Off Lights

HOA Red On/Green Off Lights

Ratings

No Pilot Devices

No Pilot Devices

NEMA Size

Hp Space (IN)

Catalog No.

Catalog No.

Catalog No.

Catalog No.

Catalog No.

Catalog No.

Full Voltage Non-Reversing (FVNR) Starters With Fusible Switch Disconnect and Melting Alloy Overload Relay

SFA001XFTMA SFA002XFTMA SFA003XFTMA SFA005XFTMA SFA007XFTMA SFA010XFTMA SFA015XFTMA SFA025XFTMA SFA040XFTMA SFA050XFTMA SFA060XFTMA SFA075XFTMA SFA100XFTMA SFA001XFTSS SFA002XFTSS SFA003XFTSS SFA005XFTSS SFA007XFTSS SFA010XFTSS SFA015XFTSS SFA025XFTSS SFA040XFTSS SFA050XFTSS SFA060XFTSS SFA075XFTSS SFA100XFTSS

SFA001AFTMA SFA002AFTMA SFA003AFTMA SFA005AFTMA SFA007AFTMA SFA010AFTMA SFA015AFTMA SFA025AFTMA SFA040AFTMA SFA050AFTMA SFA060AFTMA SFA075AFTMA SFA100AFTMA SFA001AFTSS SFA002AFTSS SFA003AFTSS SFA005AFTSS SFA007AFTSS SFA010AFTSS SFA015AFTSS SFA025AFTSS SFA040AFTSS SFA050AFTSS SFA060AFTSS SFA075AFTSS SFA100AFTSS

SFA001CFTMA SFA002CFTMA SFA003CFTMA SFA005CFTMA SFA007CFTMA SFA010CFTMA SFA015CFTMA SFA025CFTMA SFA040CFTMA SFA050CFTMA SFA060CFTMA SFA075CFTMA SFA100CFTMA SFA001CFTSS SFA002CFTSS SFA003CFTSS SFA005CFTSS SFA007CFTSS SFA010CFTSS SFA015CFTSS SFA025CFTSS SFA040CFTSS SFA050CFTSS SFA060CFTSS SFA075CFTSS SFA100CFTSS SFC001AFTMA SFC002AFTMA SFC003AFTMA SFC005AFTMA SFC007AFTMA SFC010AFTMA SFC015AFTMA SFC025AFTMA SFC040AFTMA SFC050AFTMA SFC060AFTMA SFC075AFTMA SFC100AFTMA SFC001AFTSS SFC002AFTSS SFC003AFTSS SFC005AFTSS SFC007AFTSS SFC010AFTSS SFC015AFTSS SFC025AFTSS SFC040AFTSS SFC050AFTSS SFC060AFTSS SFC075AFTSS SFC100AFTSS Catalog No.

SFA001XFSMA SFA002XFSMA SFA003XFSMA SFA005XFSMA SFA007XFSMA SFA010XFSMA SFA015XFSMA SFA025XFSMA SFA040XFSMA SFA050XFSMA SFA060XFSMA SFA075XFSMA SFA100XFSMA SFA001XFSSS SFA002XFSSS SFA003XFSSS SFA005XFSSS SFA007XFSSS SFA010XFSSS SFA015XFSSS SFA025XFSSS SFA040XFSSS SFA050XFSSS SFA060XFSSS SFA075XFSSS SFA100XFSSS

SFA001AFSMA SFA002AFSMA SFA003AFSMA SFA005AFSMA SFA007AFSMA SFA010AFSMA SFA015AFSMA SFA025AFSMA SFA040AFSMA SFA050AFSMA SFA060AFSMA SFA075AFSMA SFA100AFSMA SFA001AFSSS SFA002AFSSS SFA003AFSSS SFA005AFSSS SFA007AFSSS SFA010AFSSS SFA015AFSSS SFA025AFSSS SFA040AFSSS SFA050AFSSS SFA060AFSSS SFA075AFSSS SFA100AFSSS

SFA001CFSMA SFA002CFSMA SFA003CFSMA SFA005CFSMA SFA007CFSMA SFA010CFSMA SFA015CFSMA SFA025CFSMA SFA040CFSMA SFA050CFSMA SFA060CFSMA SFA075CFSMA SFA100CFSMA SFA001CFSSS SFA002CFSSS SFA003CFSSS SFA005CFSSS SFA007CFSSS SFA010CFSSS SFA015CFSSS SFA025CFSSS SFA040CFSSS SFA050CFSSS SFA060CFSSS SFA075CFSSS SFA100CFSSS

1 2 3 5

1

12

2 17 MOTOR CONTROL CENTERS 12 3 18

7.5 10 15 25 40 50 60 75 100

30

4

Full Voltage Non-Reversing (FVNR) Starters With Fusible Switch Disconnect and Solid State Overload Relay (Motor Logic™)

1 2 3 5

1

12

7.5 10 15 25 40 50 60 75 100

2

12

3

18

30

4

Table 17.6: FVR Combination Starter Units with Fusible Switch Disconnects Ratings Control Transformer

Fused Separate Control

Forward-Rev.-Stop PB, Forward/Reverse Lights

Forward-Rev.-Stop PB, Forward/Reverse Lights

No Pilot Devices

No Pilot Devices

Space (IN)

NEMA Size

Catalog No.

Catalog No.

Catalog No.

Hp

Full Voltage Reversing (FVR) Starters With Fusible Switch Disconnect and Melting Alloy Overload Relay

SFC001XFTMA SFC002XFTMA SFC003XFTMA SFC005XFTMA SFC007XFTMA SFC010XFTMA SFC015XFTMA SFC025XFTMA SFC040XFTMA SFC050XFTMA SFC060XFTMA SFC075XFTMA SFC100XFTMA SFC001XFTSS SFC002XFTSS SFC003XFTSS SFC005XFTSS SFC007XFTSS SFC010XFTSS SFC015XFTSS SFC025XFTSS SFC040XFTSS SFC050XFTSS SFC060XFTSS SFC075XFTSS SFC100XFTSS

SFC001XFSMA SFC002XFSMA SFC003XFSMA SFC005XFSMA SFC007XFSMA SFC010XFSMA SFC015XFSMA SFC025XFSMA SFC040XFSMA SFC050XFSMA SFC060XFSMA SFC075XFSMA SFC100XFSMA SFC001XFSSS SFC002XFSSS SFC003XFSSS SFC005XFSSS SFC007XFSSS SFC010XFSSS SFC015XFSSS SFC025XFSSS SFC040XFSSS SFC050XFSSS SFC060XFSSS SFC075XFSSS SFC100XFSSS

SFC001AFSMA SFC002AFSMA SFC003AFSMA SFC005AFSMA SFC007AFSMA SFC010AFSMA SFC015AFSMA SFC025AFSMA SFC040AFSMA SFC050AFSMA SFC060AFSMA SFC075AFSMA SFC100AFSMA SFC001AFSSS SFC002AFSSS SFC003AFSSS SFC005AFSSS SFC007AFSSS SFC010AFSSS SFC015AFSSS SFC025AFSSS SFC040AFSSS SFC050AFSSS SFC060AFSSS SFC075AFSSS SFC100AFSSS

1 2 3 5

18

1

7.5 10 15 25 40 50 60 75 100

18

2

3

27

39

4

) Full Voltage Reversing (FVR) Starters with Fusible Switch Disconnect and Solid State Overload Relay (Motor Logic

1 2 3 5

18

1

7.5 10 15 25 40 50 60 75 100

2

18

3

27

4

39

17-6