SE Digest 178
Dimensions
Meter Sockets
Class 4131 / Refer to Catalog 4100CT0701
www.se.com/us
Dimensions and Knockouts for Meter Sockets
D W
D W
Hub Opening
Hub Opening
Table 2.7: Enclosure Dimensions Dimensions (Inches) Box No. H W D
D W
Solid Top
Meter Socket
Meter Socket
Hub Opening (Max. Conduit Size) [21]
Meter Socket Offset
H
H
H
E,F,G
A,B,C,D,E S
1R 10.88 2R 13.00 3R 14.00 4R 14.00 5R 15.00 6R 15.50 7R 17.13 8R 19.00 9R 19.00 10R 34.50 11R 36.62 12R 43.00 13R 14.12 13R1 14.12 14R 14.12 15R 14.12 16R 14.12 17R 14.12 18R 14.12 19R 14.12 20R 14.12
8.00
3.50 4.94 4.38 4.38 4.38 4.36 4.94 4.94 4.94 5.68 5.68 6.00 4.50 4.50 4.50 4.50 4.50 5.38 5.38 5.38 5.38
SeriesA SolidTop SeriesA SeriesA SeriesA SeriesA
13.00 2 METERING EQUIPMENT
8.00 11.00 11.00 8.00 13.00 10.50 13.00 15.00 15.00 20.25 24.31 32.50 40.62 48.75 57.00 24.31 40.62 54.75 63.00
S
C,D,E,F,G
A,B,C,D
F,G,H
C,D,E,F A,B,C,D
A
S A
1R
3R, 6R
2R
(2) Series A SeriesA-L SeriesA-L SeriesA-L SeriesA-L SeriesA-L
Hub Opening
D W
D W
Hub Opening
Hub Opening
D W
Meter Socket
Meter Socket
Meter Socket Offset
SeriesA SeriesA SeriesA SeriesA SeriesA SeriesA
H
H
H
F,G,H
C,D,E,F,G S A
D,E,F,G S A
A,B
A,B
S
A F,G,H
D,E,F,G
F,G,H
SeriesA-L (2) Series A-L (2) Series A-L
4R, 5R
8R
7R
D W
D W
D W
Hub Opening
Hub Opening
Hub Opening
Table 2.8: Knockout Information Knockouts Symbol S A B
Meter Socket
Meter Socket Offset
Meter Socket
C D 1 1-1/4
Conduit Size (in.)
5/16
H
H
H
1/2
3/4
[22]
F,G,H
F,G,H,I S A
F,G,H,I S A
A,B
A,B
Symbol
E
F 2
G H I
J
A
S
Conduit Size (in.)
1-1/2
2-1/2
3 3-1/2 4
F,G,H
F,G,H,I
F,G,H,I
9R
10R
11R
Hub Opening
D W
Hub Opening
W
D
Hub Opening
W
D
Meter Socket
Meter Socket
Meter Socket
Main Lugs
Main Lugs S A
H
H
H
G,H,I,J
S A
C,D,E,F,G (14R, 18R)
C,D,E,F,G (14R, 18R)
C,D,E,F,G (14R) F,G,H (18R)
C,D,E,F,G (13R, 17R)
C,D,E,F,G (13R, 17R)
C,D,E,F,G (13R) F,G,H (17R)
A,B
14R and 18R
12R
13R and 17R
Meter Socket Left position omitted on 5-Gang unit (15R)
Hub Opening
W
D
Hub Opening
W
7.50 191
D
Supplied with (2) ACP Closing Plates. Order A-Hubs separately for overhead service feed.
Main Lugs S A
H
Meter Socket
22.44 570
Main Lugs S A
H
C,D,E,F,G
C,D,E,F,G
C,D,E,F,G
C,D,E,F,G
C,D,E,F,G
C,D,E,F,G
15R and 16R
13R1
30.00 762
Meter Socket Left position omitted on 5-Gang unit (19R)
C,D,E (3 Locations) E,F,G,H (8 Locations)
Hub Opening (2 Locations)
W
D
Main Lugs
H
S A
A,B
EMT1225CB and EMT3225CB
F,G,H (19R, 20R)
C,D,E,F,G (19R, 20R)
C,D,E,F,G (19R, 20R)
19R and 20R
[21] Refer to page 2-3 for closing plates and hubs. [22] Knockout for grounding conductor.
2-4
© 2019 Schneider Electric All Rights Reserved
11/20/2019
Made with FlippingBook flipbook maker