Vacuum Contactors and Starters, Full Voltage
NEMA Style Contactors, 1500 V
Class 8502 / Refer to Catalog 8502CT9701
www.se.com/us
General Information—Type V Vacuum Contactors The Class 8502 Type V vacuum contactor is a three-pole device rated 1500 V that meets UL508 (1.5 kV) and CSA. Vacuum technology offers long life and low maintenance in a compact, lightweight design. The contactor is suitable for contaminated atmospheres because the main contacts are sealed in vacuum bottles. Also, since gravity is not used to assist contactor operation, the Class 8502 contactor can be mounted in any plane without special modifications. Type V vacuum contactors are designed for the control of inductive or non-inductive loads at voltages from 200–1500 Vac. NOTE: In Table 16.119, replace the three bullets (●●●) in the catalog number with the coil voltage code. Refer to the standard coil voltage codes listed in Table 16.122. Table 16.119: Class 8502—Full Voltage 3 Pole Vacuum Contactors NEMASize Enclosed Ampere Rating Locked Rotor Current (A) Motor Voltage Max. Hp OpenStyle Type
16 NEMA AND DEFINITE PURPOSE CONTACTORS AND STARTERS
200 230 460 575 800
50 60
125 150 200 250 400 100 125 250 300 400 800 150 200 400 400 —
4
160
1080
VFO3●●●
1000 1500 200 230 460 575 800 1000 1500 200 230 460 575 800 1000 1500
Class 8502 Type VF
3.60 91
Recess for Auxiliary Contact
5
320
2160
VGO3●●●
6
540
4320
VHO3●●●
Overtravel Gauge
— —
1300 Table 16.120: Class 9998—Replacement Coils for Class 8502/8702 (contains rectifier)
5.87 149
Front View Shown Without Overtravel Gauge
Suffix (the complete coil number consists of the Class, Type, and suffix) 110/120V 220/240V 440/480V 550/600V
Class andType 9998WF 9998WG 9998WH
Size Type Poles
3 3 3
120 120 120
240 240 240
480 480 480
600 600 600
4 5 6
VF VG VH
Table 16.121: Class 9999—Vacuum Starter Kits For Use With Kit Description
Class9999 Type
6.63 168
Type
Size 4–5 6 4 5–6
VF–VG VH VF VG–VH
Auxiliary Contacts, Non-Convertible 1 N.O. & 1 N.C. Isolated Contacts
WX11
Coil Circuit Auxiliary Contacts 1 N.O. & 1 N.C. Isolated Contacts, Delayed Break 1 N.C. Isolated Contact
WCX11 WLX01
1.44 37
1.44 37
5 6
LUW5 LUW6
VG VH
Lug Kits, 6 lugs included
4.63 118
Table 16.122: Coil Voltage Codes Voltage 110 120
Dimensions for Class 8502 Type VF Size 4
220
240
440
480
550
600
50Hz 60Hz
V02
— V03
— V06
— V07
—
For How to Order Information, see page 16-28.
— V02
— V03
— V06
— V07
6.20 157
Line Terminals: Six 3/0 - 16 Tapped Holes
7.00 178
5.20 Line 132
14.00 356
6.75 171 Mtg.
1
1
8.00 203 Mtg.
2 Coil Terminal A Coil Terminal C
8.94 227
Coil Terminal A
Line and Load Terminals: One .50 - 13 Tapped Hole Per Terminal
2
Coil Terminal C
Load Terminals: Six 3/0 - 16 Tapped Holes
5.05 Load 128
5.75 146 Std.
6.75 Mtg. 171
7.75 197
7.90 201
7.00 178
1. Two dual circuit auxiliary contacts can be located on both sides of contactor. 2. Coil Terminals B and D located on opposite side of contactor.
1. Two dual circuit auxiliary contacts can be located on both sides of contactor. 2. Coil terminals B and D located on opposite side of contactor.
Dimensions for Class 8502 Type VG Size 5
Dimensions for Class 8502 Type VH Size 6