Type S Full Voltage Contactors and Starters
Contactors, Type S
Class 8502 / Refer to Catalog 8502CT9701
www.se.com/us
Single-Phase and 4- and 5-Pole Polyphase— NEMA 4X, 7 & 9, and 12/3R Enclosures
NOTE: In Table 16.87, replace ●●● with the voltage code shown in Table 16.83. For information on field modification of NEMA 12 enclosures, see page 16-112.
Table 16.87: 600 Vac Maximum—50–60 Hz
NEMA4X Watertight, Dusttight Corrosion-Resistant Glass-Polyester Enclosure
NEMA7&9,Div.1&2 Hazardous Locations Class I, Groups C & D Class II, Groups E, F & G
NEMA12/3R [9] Dusttight & Driptight Industrial Use Enclosure
NEMA Size 16 NEMA AND DEFINITE PURPOSE CONTACTORS AND STARTERS Continuous Current Ratings Motor Voltage 1-Pole Single Phase 0 18
Max. Hp
Bolted Type
SpinTop™ Type
Type
Type
Cast Iron [10]
Cast Aluminum [11]
115 230 115 230 115 230 115 230 115 230 115 230 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575
1 2 2 3
— — — —
SBT5●●●
SBT45●●●
SBR5●●●
SBA5●●●
SCT5●●●
SCT45●●●
SCR5●●●
SCA5●●●
1
27
2-Pole Single Phase 00 9
1/3 1
UseSize0
UseSize0
UseSize0
UseSize0
1 2 2 3
SBW21●●●
SBT1●●●
SBT41●●●
SBR1●●●
SBA1●●●
0
18
SCW21●●●
SCT1●●●
SCT41●●●
SCR1●●●
SCA1●●●
1
27
3 7-1/2
SDW21●●●
SDT1●●●
SDT41●●● SET41●●● SFT41●●●
SDR1●●● SER1●●● SFR1●●●
SDA1●●● SEA1●●● SFA1●●● SGA1●●● SHA1●●● SJA1●●●
2 3 4 5 6 7
45 90
— — Consult the Customer Care Center at 1-888-778-2733. — —
— — — — —
135 270 540 810
— — — — — —
— — —
— — —
— — —
4-Pole Polyphase
3 3 5 5
0
18
SBW23●●●
SBT3●●●
SBR3●●●
SBA3●●●
7-1/2 7-1/2
SCW23●●●
SCT3●●●
SCR3●●●
SCA3●●●
1
27
10 19 10 15 25 25 25 30 50 50 40 50
Consult the Customer Care Center at 1-888 778-2733.
SDW23●●●
SDT3●●●
SDR3●●●
SDA3●●●
2
45
SER3●●●
SEA3●●●
3
90
Consult the Customer Care Center at 1-888 778-2733.
SFR3●●●
SFA3●●●
4
135
100 100
5-Pole Polyphase
3 3 5 5
0
18
—
—
—
SBA4●●●
575
7-1/2 7-1/2
—
—
—
SCA4●●●
1
27
10 10 10 15 25 25 25 30 50 50 40 50
Consult the Customer Care Center at 1-888-778-2733.
2
45
—
—
—
SDA4●●●
3
90
—
—
—
SEA4●●●
4
135
—
—
—
SFA4●●●
100 100
Coil voltage codes and page number reference for additional information are shown on page 16-29. For How to Order Information, see page 16-28.
[9] NEMA 12 enclosures can be field modified for outdoor non-corrosive and non–service entrance rated applications. [10] Limited to one pilot light, and a selector switch or Start-Stop push button. [11] NEMA 7 and 9 bolted cast aluminum are not UL listed.
16-32