SE Digest 178
Accessories
TeSys™ N Contactors and Starters
Refer to Catalog MKTED210011EN
www.se.com/us
Auxiliary Contacts, Time Delay, Mechanical Latch Table 16.49: Standard, Instantaneous Auxiliary Contact Blocks Snap-On Mounting Number of Contacts Composition
Catalog Number
N.O.
N.C.
LADN22 [14] LADN13 [14] LADN40 [14] LADN04 [14] LADN31 [14] LADC22 [15] LADN11 [14] LADN20 [14] LADN02 [14]
2 1 4 0 3 1 2 0 1 0 1 2
2 3 0 4 1 1 0 2 0 1 1 0
4
To front of Size00–2 or To right side of Size3–7
16 NEMA AND DEFINITE PURPOSE CONTACTORS AND STARTERS
2 [15]
2 [15]
2
Front Mounted Auxiliary Blocks
LADN10 LADN01
To left side of Size3–7
1
LAD8N11 [16] LAD8N20 [16]
Tosideof Size00–2
2
Table 16.50: Instantaneous Blocks with Dust-Tight Auxiliary Contacts (IP54) NEMA12
Snap-On Mounting
Standard Contacts Dust-Tight Contacts
Catalog Number
N.O.
N.C.
N.O.
N.C.
To front of Size00–2 or To right side of Size3–7
— — 2
— — —
LA1DX20 LA1DZ40 LA1DZ31
2 1
— 2
1
2
— LA1DY20 [17]
— — 2
Table 16.51: Pneumatic Time Delay Contact Blocks Snap-On Mounting TimeDelay Contacts Type
Rangeof TimeDelay 0.1 to3s [19] 0.1 to30s 10 to180s 1 to30s [20] 0.1 to3s [19]
Catalog Number [18]
N.O.
N.C.
LADT0 LADT2 LADT4 LADS2 LADR0 LADR2
On energization (ondelay)
To front of Size00–2 or To right side of Size3–7
1
1
Onde energization (off-delay)
1
1
0.1 to30s 10 to180s
LADR4 Table 16.52: Mechanical Latch Blocks with Manual or Electrical Unlatch
Front snap-on mounting onto
Application
Catalog Number
For silent operation and energy conservation
LAD6K10 [21][22]
Size00–2
Table 16.53: Coil Voltage Codes for LA6DK Mechanical Latch Blocks Volts 24 120 208 240
480
ACorDC [23]
B
F
L
M
R
[14] For spring terminal versions of these blocks, add a 3 to the end of the catalog number (for example, LADN22 3 ). For slip-on versions, add 9 to the end of the catalog number (for example, LADN22 9 ). [15] Including 1 N.O. + 1 N.C. make-before-break overlapping contacts. [16] 1 block may be added to the left side of Size 00–1, AC coils only; only 1 block may be added to either side of the Size 2 contactor, AC coil only. Cannot be installed on Size 00–2 contactors with DC coils. [17] Device comes with 4 ground terminal points. [18] For spring terminal versions of these blocks, add a 3 to the end of the catalog number (for example, LADT2 3 ). There is no charge for this modification. [19] Scale range is expanded between 0.1 and 0.6 seconds on the dial for more accurate settings at the lower end of the range. [20] Switching time between the opening of the N.C. contact and the closing of the N.O. contact: 40 ms ± 15 ms . [21] Complete the catalog number by adding the coil voltage code (for example, LAD6K10F). [22] Does not include internal coil clearing contact. [23] DC available at 24 V only.
16-18
© 2019 Schneider Electric All Rights Reserved
11/20/2019