SE Digest 178
Combination Service Entrance Devices
Circuit Breakers for CSEDs
Class 4119, 4120
1 LOAD CENTERS Table 1.84: All-in-One Combination Service Entrance Devices Surface and Semiflush Mount [53] Ring Type, Homeline 300A Class 320 Manual UG — 25kA SU3040D300CB [54][55] [56] 1 SU3040D300FB [54][55] [56] 1
www.se.com/us
QDL22200 [57] QDL, QGL, QJL [58]
200A 100A 30 40
10 200 A A–L (2) Studs 4–250 100, 4
SU3040D400CN [54] [55] SU3040D400FN [54][55] SU3040D400CB [54][55] [56] SU3040D400FB [54][55] [56] RU3040D400CL [55][59] [56] RU3040D400FL [55][59] [56] RU3040D400CK [55] [56]
1 1
QDL22200 [57] QDL, QGL, QJL [58]
200A 200A 30 40
400 A None UG UG 25 kA
10 200 A A–L (2) Studs 4–250 100, 4
QDL22200 [57]
1
200A
Class 320 Manual
400A
UG — 25kA
30 40
10 200 A A–L (2) Studs 4–250 100, 4
1 QDL, QGL, QJL [58]
200A
Ringless, Homeline
QDL22200 [57]
200A
1
Class 320 Lever
30 40
10 200 A A–L (2) Studs 4–250 100, 4
400A
UG — 25kA
1 QDL, QGL, QJL [58]
200A
1 1
QDL22200 [57] QDL, QGL, QJL [58]
200A 200A 30 40
10 200 A A–L (2) Studs 4–250 100, 4
400 A K-4 Bolt- on UG — 25kA
RU3040D400FK OBS
OBS This product is obsolete.
Circuit Breakers for CSEDs
Table 1.85: Circuit Breakers for use with Meter Mains and All-In-One Devices Ampere Rating [60] Type: HOM, 1P Type: HOM, 2P Type: QO, 1P
Type: QO, 2P
Type: QO-VH, 1P
Type: QO-VH, 2P
Cat.No. (DE3D)
Cat. No. (DE3D)
Cat. No. (DE2A) QO110 QO115 QO120 QO125 QO130 QO135 QO140 QO150 QO160 QO170
Cat. No. (DE2A)
Cat.No. (DE2A)
Cat. No. (DE2A)
10 15 20 25 30 35 40 45 50 60 70 80 90
—
— — — —
— — — —
—
— — — —
QO115VH QO120VH
HOM115 HOM120 HOM125 HOM130
QO125VH OBS
QO230 QO235 QO240 QO245 QO250 QO260 QO270 QO280 QO290 QO2100 QO2110 QO2125 QO2150 QO2175 QO2200
QO130VH
QO230VH
HOM230 HOM235 HOM240 HOM245 HOM250 HOM260 HOM270 HOM280 HOM290 HOM2100 HOM2110 HOM2125
—
— — — — — — — — — — — — — —
—
QO240VH
HOM140
QO145 OBS
—
—
QO250VH QO260VH QO270VH QO280VH QO290VH QO2100VH QO2110VH QO2125VH QO2150VH
HOM150
— — — — — — — — — —
— — — — — — — —
100 110 125 150 175 200
HOM2150BB HOM2175BB HOM2200BB
QO2175VH OBS
QO2200VH
OBS This product is obsolete.
Ampere Rating [60]
Type: QOM1-VH, 2P
Type: QOM2-VH, 2P
Type: QDL, 2P [61] Cat. No. (DE2A)
Cat. No. (DE3D) QOM50VH [62]
Cat. No. (DE3D)
50 60 70 80 90
— — — — —
— —
QOM60VH QOM70VH QOM80VH QOM90VH QOM100VH QOM110VH QOM125VH
QDL22070 QDL22080 QDL22090 QDL22100 QDL22110 QDL22125 QDL22150 QDL22175 QDL22200
QOM2100VH
100 110 125 150 175 200 225
—
QOM2125VH QOM2150VH QOM2175VH QOM2200VH QOM2225VH
— — — —
—
[53] UL short circuit current rating is equal to the lowest interrupting rating of any circuit breaker installed. [54] For use only on 120/240 Vac 1Ø3W system (4-jaw meter socket). [55] Knockout provided in cover for use with barrel lock kit SCBRLLOCK (see Accessories). [56] Device configuration is not included in EUSERC standards. Consult applicable utility for acceptance. [57] Service disconnect supplied factory-installed. [58] Additional service disconnect for field-installation: order prefix QBL at 10 kA, QDL at 25 kA, QGL at 65 kA, or QJL at 100 kA. Order separately. For complete circuit breaker catalog number, see Digest Section 7. [59] 5th jaw factory-installed. [60] Do not exceed mains rating of device [61] For additional interrupting rating circuit breakers, order circuit breaker prefix QBL at 10 kA, QGL at 65 kA or QJL at 100 kA. [62] Reference National Electrical Code Article 230-79.
1-40
© 2021 Schneider Electric All Rights Reserved July 30, 2021
Made with FlippingBook flipbook maker