Table 9.37: NQ Merchandised Neutral Assemblies Mains Rating (Amps)
Copper 100% Neutral Kit
200% Neutral Kit
Catalog No.
Space Factor
Catalog No.
Space Factor
NQNL1 NQNL2
NQN1CU NQN2CU
100 225 225 400 600
0 0 6 0
0 0
NQNL2ACCY [90]
NQNL4 [91]
100A 9 PANELBOARDS 225A
NQN6CU
0
– 0 Table 9.38: NQ Merchandised Sub-feed Lugs, Feed-through Lugs, and Sub-feed Breaker Kits Mains Rating Sub-feed Lugs Catalog Number Feed-through Lugs Catalog Number
Sub-feed Circuit Breaker Kits (breaker not incl.) SingleSFB TwoSFBs
100 A not available; use 225 A interior
NQSFL1
—
—
NQFTL2L [92] NQFTL2H [93] NQFTL4L [92] NQFTL4H [93]
NQSFL2
NQSFB2Q or NQSFB2HJ
—
NQSFB4Q or NQSFB4HJ or NQMB6PPL [94]
NQSFL4
NQSFB4Q or NQSFB4HJ
400A
Factory Assembled Only
Factory Assembled Only
NQMB6PPL [94]
Factory Assembled Only
600A
NOTE: See Table 9.39 and Table 9.40. Table 9.39: Box Selection Table: Merchandised NQ Main Lug Panelboards with Accessories
Sub-feed Lugs
Feed-through Lugs
Sub-feed Circuit Breakers
Feature Circuits
225A (one)
400A (two)
400A / 600 A(one)
600A(two)
100 A 225 A 400 A
600A
100 A 225 A 400 A — — —
600A 100A
18 30 42 54 72 84
MH26
— —
— — —
—
MH32 MH38 MH50 — MH44 MH50 — MH44 MH56 — MH50 MH62 — MH56 MH68
MH38 MH38 MH44 MH50 MH56
MH50 MH56 MH62 MH68 MH68
— MH50 — MH56 — MH56 — MH62 — MH68
MH74 MH74 MH80 MH86 MH92
MH62D9 MH62D9 MH68D9
Factory Assembled Only
Factory Asssembled Only
Factory Asssembled Only
Use225A Interior
—
— Table 9.40: Box Selection Table: Merchandised NQ Vertically Mounted Main Breaker Panelboards w/ Accessories (by Mains Rating)
Feed-through Lugs
PowerPact H, J, or Q Sub-feed Circuit Breakers (Max Amp and Qty)
Feature Circuits
400 A (two SFB)
400A
600A(two SFB)
225A(one)
100A
225A
600A
100A
LA / LH MB PowerPacT L MB
LA / LH MB PowerPacT L MB
18 30 42 54 72 84
— — — — — —
—
—
—
—
— — — — — —
—
—
—
—
MH62 MH68 MH74 MH80 MH80
MH62 MH68 MH74 MH80
MH86 MH92
MH86D9
MH50 MH56 MH62 MH68
MH68D9 MH74D9 MH80D9 MH86D9
Factory Asssembled Only
Factory Asssembled Only
— — —
[95] [95]
Table 9.41: NQ Optional Lugs
Al Compression Lug Kit
Cu Mechanical Lug Kit
Cu Compression Kit
Ampacity
Lug Wire Range (AWG-kcmil)
Lug Wire Range (AWG-kcmil)
Lug Wire Range (AWG-kcmil)
Catalog No.
Catalog No.
Catalog No.
NQALV1 NQALV2 NQALV4 NQALV6
NQCUM1 NQCUM2 NQCUM4 NQCUM6
NQCUV1 NQCUV2 NQCUV4 NQCUV6
100 225 400 600
one#8–1/0 one#4–300 two 2/0–500 two 2/0–500
one#6–2/0 one#6–250
one#6–1/0 one 2/0–300 one 400–700 two 250–500
one 1/0–750 or two 1/0–350
Table 9.42: Add-on Lugs for Neutral Bars or Ground Bars Catalog Number Lug Wire Range (AWG - kcmil)
Wire Ampere
QO70AN [96] NQ100AN [96] Q1150AN [97] NQ200AN [96]
#12 to #2 Al or #14 to #4 Cu
70A
#14 to #2/0 Al or Cu #1 to #4/0 Al or Cu
80 - 100A 110 - 150A
(2) #4 to 300 kcmil Al or Cu 175 - 200A NOTE: A maximum of 4 lugs may be added to 18 circuit neutral assemblies. A NQ200AN is required to provide a neutral terminal for every two 175 - 200A QO (VH) circuit breakers.
[90] For 225 A panel with SFL, FTL, or SFB. [91] Not to be used with SFL, FTL, or SFB. These combinations are factory assembled only. [92] The final character L indicates the kit is used for Low circuit count interiors 30 and 42. [93] The final character H indicates the kit is used for High circuit count interiors 54, 72, and 84. [94] PowerPacT L Circuit Breakers require 8.75" deep enclosures. [95] Requires box longer than available box offer.