NQ Panelboards—240 Vac, 48 Vdc
NQ Factory Assembled Panelboards
NQ Main and Sub-feed Circuit Breakers
www.se.com/us
Factory Assembled Main Circuit Breakers 400 A and 600 A panelboards, 1Ø or 3Ø Table 9.16: NQ Panelboard Factory Assembled Interiors - 240 Vac / 48 Vdc Max Single Phase or Three Phase Mains Rating (Amps) Min. Box Depth
Max. Number of One-Pole Circuit Breakers
Bus Material
Main Circuit Breaker [72]
Main Circuit Breaker / Switch
MainLugs Only
MainLugs Only
Main Switch [72]
9 PANELBOARDS
18, 30
Al,Cu
100Max 225Max 400Max
15–100 15–250 125–400
70–100
5.75 in. 5.75 in. 5.75 in.
5.75 in. 5.75 in.
110–250 30, 42, 54, 72, 84 Al, Cu
30, 42, 54, 72 [73] , 84 [74]
5.75 in. / 8.75 in. [75]
Al,Cu
300–400
450–600 30, 42, 54, 72 [73] , 84
8.75 in. [75]
Cu
5.75 in.
600Max
125–600
Table 9.17: Main Circuit Breaker (PowerPacT L-frame - see PowerPacT Interrupting Ratings, and Common Catalog Numbering System, in Section 7) Number of Poles Trip Unit Options Frame Sizes Ampacity 3 LI, LSI, Switch LG, LJ, LL 125–600A LA/LH PowerPacT H, J, and Q-frame circuit breakers are also available - see Tables PowerPact Interrupting Ratings, page and Common Catalog Numbering System, page and Supplemental Digest Section 3. Table 9.18: PowerPacT L Main Circuit Breaker Cabinet Height (inches) [76]
NEMA 1 Enclosure (20 in. W x 8.75 in. D) [77]
Vented NEMA 3R Enclosure (26 in. W x 8.75 in. D) [76]
Max. No. of Branch Spaces (Does not include sub-feed circuit breaker spaces)
400or 600A
400A
600A
30 42 54 72 84
62 68 74 80 86
62 68 74
68 74 80
– –
– –
Sub-feed Circuit Breakers Main lugs or main circuit breaker interior—1Ø or 3Ø. Maximum 1 circuit breaker per 225 A main lug or 250 A main circuit breaker panelboard, 2 circuit breakers per 400–600 A panelboard. Panelboards in MHxxWP NEMA Type 3R/5/12 enclosures are limited to one 150 A maximum sub-feed breaker. Table 9.19: Sub-feed Circuit Breaker (see PowerPacT Interrupting Ratings, and Common Catalog Numbering System, in Section 7) Panelboard Mains Rating Sub Feed Breaker Space Factor (in.) [78] No. of Poles Ampacity MCCBFrame
2 3 2 3 2 3 2 3 2 3 2 3 3
QB, QD, QG, QJ
70–225
18
HD, HG, HJ, HL, HR
110–150
18
225A
JD, JG, JJ, JL, JR
150–225
18
QB, QD, QG, QJ
70–225
24
400A, 600A
HD, HG, HJ, HL, HR
110–150
24
JD, JG, JJ, JL, JR
150–225
24
400A
LG, LJ, LL
126–600
18
600A PowerPacT H, J, & L frame circuit breakers are also available - see Tables PowerPacT Interrupting Ratings, and Common Catalog Numbering System, Section 7. Table 9.20: PowerPacT H, J, or Q-frame Sub-feed Circuit Breaker Cabinet Height (inches) Max. No. of Branch Spaces (Does not include sub-feed circuit breaker spaces) Standard Depth Enclosures(20 in. W x 5.75 in. D) 225A 250A 400A 600A
LA/ LHMain Circuit Breaker
Main Lugs [79]
Main Lugs
Main Lugs [79]
Main Circuit Breaker
30 42 54 72 84
50 56 62 68 74
62 68 74 80 86
74 74 80 86 92
86 86 92
74 80 80 86 92
– –
[72] Factory Assembled Interiors are rated for trip current of Main Breaker / Switch. [73] Three Phase only. [74] Copper only. [75] Deep Box required for PowerPacT L Main Circuit Breaker or Switch.
[76] Feed-thru lugs and compression lugs available factory assembled only. These add 6 - 12 inches to enclosure length. [77] D9 8.75" deep enclosures are required for PowerPacT L Main Circuit Breaker, Switch, or Sub-Feed Circuit Breaker. [78] Space Factor - add this length to enclosure when adding a Sub Feed Breaker. [79] Bottom feed only in NEMA 3R enclosures.
9-18
© 2021 Schneider Electric All Rights Reserved 6/20/2021