MiCOM Busbar Applications
MiCOM Protection Relays
www.se.com/us
MiCOM Busbar Differential Applications
High Impedance Differential Protection Relays MiCOM P72x high impedance differential protection series provides high impedance differential protection for generators, reactors, motor and busbar applications.
Models available: • MiCOMP721 • MiCOMP723
MiCOM P72x apart from offering the same application benefits as traditional high impedance electromechanical protection schemes, it combines the added benefits of numerical technology to provide advanced communications, event records, fault records, disturbance records and ancillary protection features. Combined with the MiCOM P79x, a standalone metrosil and resistor unit, it provides simplified scheme engineering for single or three-phase differential applications.
P721 / P723
Numerical Busbar Protection Relay Scheme (Centralized) Easergy™ MiCOM P746 numerical busbar protection provides centralized complete protection for all voltages level up to extra high voltage busbar configurations.
Models available: • MiCOMP746
Simple configuration for centralized architecture. The Easergy MiCOM P746 differential busbar protection provides a centralized one box or three boxes architecture and is very simple to use. It does not need to be deeply engineered and supports easy operation and maintenance of the busbar. Numerical Busbar Protection Relay Scheme (Distributed) The Easergy MiCOM P740 numerical busbar protection scheme provides scalable and complete protection for all voltage levels, from low to extra or ultra high-voltage busbar configurations. Models available:
P741 / P742 / P743 / P746
• MiCOM741 • MiCOM742 • MiCOM743
Easergy MiCOM P740 is one of the fastest and complete in its class, providing secure and sensitive protection for all types of voltage busbar configurations. It is easily adapted to any configuration and can operate with different types of CT.
Table 5.40: Functions available for the different models of the Busbar protection MiCOM range of relays ANSI Protection Function P741 P742 P743
P746
50N/51N 50/51P
Ground fault
● ● ● ●
● ● ● ●
● ● ● ● ● ● ● ● ●
Phase overcurrent Circuit breaker failure
50BF 87BB 87CZ 87P 87P CTS TCS VTS
● ● ●
Busbar
Check Zones
Phase segregated differential Sensitive ground fault differential Current transformer supervision
8zones 8zones
4zones
5 PROTECTION, CONTROL, AND ENERGYAUTOMATION
● ●
● ● ●
● ● ●
Trip circuit supervision
Voltage transformer supervision
Phase comparison
CT saturation detection
● ●
● ●
CT supervision
●
Table 5.41: Typical Catalog Numbers Catalog Number Standard — High Impedance Busbar Differential P723 with external stabilizing resistor P793 Advanced — Low impedance Busbar Differential (1 or 3 box mode)
Description
Series 20 - High Impedance bus differential Protection, P723 (24-250Vdc & 48-240Vac), 1/5A CT inputs, 5In/8Out (24-250 Vdc, 24-240Vac), RS485, Modbus
P723000Z112CB0
External stabilizing resistor, 20kJ
P793CF0E2
Series 40 - Low Impedance bus differential (7 sets of CT's) Protection, P746 (48-110Vdc), 1/5A CT inputs, 16In/16Out (user configurable voltage thresholds), 3xRJ-45, IEC61850, DNP3
P74622RABM0C48M
5-23