SE Digest 178

Drives Overview

Open AC Drives

Panel Mounted / Open AC Drive Solutions

www.se.com/us

Overview of Altivar™ 212 / 61 and Altivar™ Process 600

Type of Motor Control Key Application/Market Segment

Centrifugal Pumps and Fans

Pumps and Fans

• Pumps • Fans • General purpose applications in: – Water & Wastewater – Oil &Gas – Mineral, Mining & Metals – Food & Beverage

• Pumps • Fans

• Pumps • Fans

Drives

Altivar 212

Altivar 61

Altivar Process 600

Three-phase 200–240 V Three-phase 380–480 V Three-phase 500–600 V Three-phase 500–690 V

Distribution voltage ranges for 50/60 Hz line supply

Three-phase 200–240 V Three-phase 380– 480 V

Three-phase 500–690 V

1–100 hp, 208/230 V 1–500 hp, 400/480 V 1–100 hp, 400/480 V (ATV650)

Horsepower ratings for three-phase motors

1–40 hp, 208/230 V 1–100 hp, 400/480 V

2– 900 hp, 575/690 V

3–100 hp, 500/600 V 3–125 hp, 500/690 V

Output frequency

0.5–500 Hz from 50–900 hp

0–200Hz

0.1–500Hz

Type of Control Asynchro nousmotor

Volts per hertz ratio (2 or 5 points) or sensorless flux vector control, energy-saving ratio

Voltage/frequency: quadratic, 2 point or 5 points, or optimized for energy savings Vector control for permanent magnet motors Normal Duty: 110% of the nominal motor torque for 60 s. Heavy Duty: 150% of the nominal motor torque for 60 s. >30 pump dedicated functions, additional for fan and material handling applications

Volts per hertz or sensorless flux vector control Permanent magnet motor control without speed feedback Transient overload: 110% of the nominal drive current for 60 seconds

Drives

Synchronous motor Transient overtorque

Vector control without speed feedback

Functions Number of Functions 26 AC DRIVES AND SOFT STARTERS 50 Analog inputs 2

170% of the nominal motor torque for 2 seconds 110% for 60 seconds

>100

2–4

3–5

Analog outputs

1

2

Logic inputs 3

6–20

6–12

Number of I/O

Logic/Relay outputs

2: 1 N.O./1 N.C. and 1 N.O. relay contacts

2–4

3–6

Safety function inputs

2

Integrated Modbus™, Apogee P1, BACnet, Metasys® N2

Modbus™ and CANopen • Apogee FLN ( P1) • BACnet • Modbus/Uni-Telway • LonWorks • EtherNet/IP and Modbus/TCP Dual Port

Modbus/Ethernet TCP and Modbus Serial Link

• Modbus Plus • InterbusS • DeviceNet • Profibus DP [V1] • MetasysN2

• EtherNet/IP and Modbus/TCP Dual Port • EtherNet/IP and Modbus/TCP Dual Port with MultiVFD • BACnet MS/TP • CANopen: Daisy Chain RJ45, Sub-D, and Screw Terminals • ProfiNet • Profibus DP V1 • DeviceNet

- LonWorks

Communi cation

Available as anoption

I/O extension cards, IMC programmable card, Multi-pump cards IP20, Type 1 with optional kit, Type 12 @460 Vac IEC/EN 61800-5-1, IEC/EN 61800-3 (environments 1 and 2, C1 to C3), EN 55011, EN 55022, UL 1995 Plenum-rated, IEC/EN 61000-4-2/4-3/4-4/4-5/4-6/4-11, CE, UL, CSA, DNV, C-TICK, NOM 117, GOST, ABS

Other Option Cards

I/O extension cards

IP20, Type 1 with optional kit, Type 12@460Vac EN 50178, IEC/EN 61800-3, EN 55011, 55022: class A, class B with option, CE, UL, C-TICK, N998, UL1995

Enclosure Rating

Type 1, Type 12 (ATV650 only)

UL 508C, UL File E116875, CSA, TUV, REACH, UL50, EN/ IEC 61800-3, EN/IEC 61800-3 environment 1 category C2, EN/IEC 61800-3 environment 2 category C3, EN/IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508

Standards and Certifications

Plenum-rated AHRI Certified

26-6

© 2019 Schneider Electric All Rights Reserved

11/20/2019

Made with FlippingBook flipbook maker