SE Digest 178
Drives Overview
Open AC Drives
Panel Mounted / Open AC Drive Solutions
www.se.com/us
Overview of Altivar™ 212 / 61 and Altivar™ Process 600
Type of Motor Control Key Application/Market Segment
Centrifugal Pumps and Fans
Pumps and Fans
• Pumps • Fans • General purpose applications in: – Water & Wastewater – Oil &Gas – Mineral, Mining & Metals – Food & Beverage
• Pumps • Fans
• Pumps • Fans
Drives
Altivar 212
Altivar 61
Altivar Process 600
Three-phase 200–240 V Three-phase 380–480 V Three-phase 500–600 V Three-phase 500–690 V
Distribution voltage ranges for 50/60 Hz line supply
Three-phase 200–240 V Three-phase 380– 480 V
Three-phase 500–690 V
1–100 hp, 208/230 V 1–500 hp, 400/480 V 1–100 hp, 400/480 V (ATV650)
Horsepower ratings for three-phase motors
1–40 hp, 208/230 V 1–100 hp, 400/480 V
2– 900 hp, 575/690 V
3–100 hp, 500/600 V 3–125 hp, 500/690 V
Output frequency
0.5–500 Hz from 50–900 hp
0–200Hz
0.1–500Hz
Type of Control Asynchro nousmotor
Volts per hertz ratio (2 or 5 points) or sensorless flux vector control, energy-saving ratio
Voltage/frequency: quadratic, 2 point or 5 points, or optimized for energy savings Vector control for permanent magnet motors Normal Duty: 110% of the nominal motor torque for 60 s. Heavy Duty: 150% of the nominal motor torque for 60 s. >30 pump dedicated functions, additional for fan and material handling applications
Volts per hertz or sensorless flux vector control Permanent magnet motor control without speed feedback Transient overload: 110% of the nominal drive current for 60 seconds
Drives
Synchronous motor Transient overtorque
Vector control without speed feedback
Functions Number of Functions 26 AC DRIVES AND SOFT STARTERS 50 Analog inputs 2
170% of the nominal motor torque for 2 seconds 110% for 60 seconds
>100
2–4
3–5
Analog outputs
1
—
2
Logic inputs 3
6–20
6–12
Number of I/O
Logic/Relay outputs
2: 1 N.O./1 N.C. and 1 N.O. relay contacts
2–4
3–6
Safety function inputs
—
—
2
Integrated Modbus™, Apogee P1, BACnet, Metasys® N2
Modbus™ and CANopen • Apogee FLN ( P1) • BACnet • Modbus/Uni-Telway • LonWorks • EtherNet/IP and Modbus/TCP Dual Port
Modbus/Ethernet TCP and Modbus Serial Link
• Modbus Plus • InterbusS • DeviceNet • Profibus DP [V1] • MetasysN2
• EtherNet/IP and Modbus/TCP Dual Port • EtherNet/IP and Modbus/TCP Dual Port with MultiVFD • BACnet MS/TP • CANopen: Daisy Chain RJ45, Sub-D, and Screw Terminals • ProfiNet • Profibus DP V1 • DeviceNet
- LonWorks
Communi cation
Available as anoption
I/O extension cards, IMC programmable card, Multi-pump cards IP20, Type 1 with optional kit, Type 12 @460 Vac IEC/EN 61800-5-1, IEC/EN 61800-3 (environments 1 and 2, C1 to C3), EN 55011, EN 55022, UL 1995 Plenum-rated, IEC/EN 61000-4-2/4-3/4-4/4-5/4-6/4-11, CE, UL, CSA, DNV, C-TICK, NOM 117, GOST, ABS
Other Option Cards
—
I/O extension cards
IP20, Type 1 with optional kit, Type 12@460Vac EN 50178, IEC/EN 61800-3, EN 55011, 55022: class A, class B with option, CE, UL, C-TICK, N998, UL1995
Enclosure Rating
Type 1, Type 12 (ATV650 only)
UL 508C, UL File E116875, CSA, TUV, REACH, UL50, EN/ IEC 61800-3, EN/IEC 61800-3 environment 1 category C2, EN/IEC 61800-3 environment 2 category C3, EN/IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508
Standards and Certifications
Plenum-rated AHRI Certified
26-6
© 2019 Schneider Electric All Rights Reserved
11/20/2019
Made with FlippingBook flipbook maker