SE Digest 178

Legacy Power Relays Refer to Catalog 8501CT1003

General Purpose Relays

www.se.com/us

199 Power Relays

199 — SPST-NO-DM, 40 A; SPDT, 40 A; DPST-NO, 40 A; DPDT, 40 A Table 23.40: Standard Part Numbers Rated Contact Current Contact Configuration Coil Voltage Coil Resistance (Ω) Special Features

Standard Part Number

120Vac 12Vdc

290

199ADX-4 199DX-2 199DBX-3 199DX-3 199DBX-16 199AX-4 199X-2 199X-3 199AX-9 199AX-10 199AX-13 199ABX-14 199AX-14 199AX-15 199BX-12 199X-12 199BX-13 199X-13 199BX-14 199X-14 199X-7 199X-8

70

23 RELAYS AND TIMERS

Blowout Magnet

SPST-NO-DM

24Vdc

290

Blowout Magnet

48Vdc 120Vac 12Vdc 24Vdc 120Vac 240Vac 12Vdc 24Vdc 24Vac 120Vac 240Vac

1200

290

SPDT

70

290 290

1200

DPST-NO

70

40A [24]

290

12

Blowout Magnet

290

1200

Blowout Magnet

12Vdc

70

DPDT

Blowout Magnet

24Vdc

290

Blowout Magnet

110Vdc

6000

199 Series Relay

199 Specifications (UL 508)

199AX, 199X, 199ABX [25] , 199BX [25]

199ADX, 199DX, 199DYX, 199DBX [25]

Part Numbers

Contact Characteristics Contact Configuration

SPST, SPDT, DPST, DPDT

SPST-DM, SPST-DB

Silver alloy

Contact Material

Thermal (Carrying) Current Maximum Switching Voltage

40A

600V(rms)

Resistive: 40 A at 300 Vac 50/60 Hz; 5 A at 480 Vac 50/60 Hz; 5 A at 600 Vac 50/60 Hz; 40 A at 28 Vdc Motor: 2 hp at 120–600 Vac 50/60 Hz Tungsten: 15 A at 120 Vac 50/60 Hz Pilot Duty: A600

Resistive: 40 A at 300 Vac 50/60 Hz; 12 A at 480 Vac 50/60 Hz; 10 A at 600 Vac 50/60 Hz; 40 A at 28 Vdc

Rated Switching Current at Voltage

Minimum Switching Requirement

1 A at 5 Vac/Vdc

Coil Characteristics Coil Voltage Range [26]

6–600 Vac 50/60 Hz; 6–250 Vdc2 85%–110% (AC); 80%–110% (DC)

Operating Range (% of Nominal) Average Consumption (Maximum)

10 VA (AC); 4 W (DC)

Drop-Out Voltage Threshold

10% (AC/DC)

Table 23.41: Additional DC Ratings with Blowout Magnet Load Voltage Contact Rating 110Vdc 20A 220Vdc 8A 325Vdc 4A 500Vdc 2A Table 23.42: Auxiliary Switch Ratings (Non-Standard Option) LoadType Contact Rating Resistive Load 120/250 Vac (50/60 Hz) 10A Motor Load 125/250 Vac (50/60 Hz) 0.25hp Tungsten Load 125 Vac (50/60 Hz) 3A

[24] 50 A versions and additional options available. Call Customer Service for more information (847-441-2540). [25] For ratings with blowout magnet, refer to Table 23.41 Additional DC Ratings with Blowout Magnet , page 23-48 [26] For available standard coil voltages, refer to Standard Part Numbers, page 23-48