Power Factor Improving DC Reactor (FR-HEL, FR-HEL-H, MR-DCL) This boosts the power factor of servo amplifier and reduces the power supply capacity. Use either the DC reactor or the AC reactor. As compared to the AC reactor (FR-HAL or FR-HAL-H), the DC reactor (FR-HEL or FR-HEL-H) is more recommended since the DC reactor is more effective in power factor improvement, smaller and lighter, and its wiring is easier. (The DC reactor uses two wires, while the AC reactor uses six wires.) A-RJ A B-RJ B GF-RJ GF

Servo Amplifiers Rotary Servo Motors Linear Servo Motors Direct Drive Motors Options/Peripheral Equipment Product List LVS/Wires Cautions

Power factor improving DC reactor model

Power factor improving DC reactor model

Servo amplifier model

Fig.

Servo amplifier model

Fig.

MR-J4-10GF/B/A FR-HEL-0.4K MR-J4-20GF/B/A MR-J4-40GF/B/A FR-HEL-0.75K MR-J4-60GF/B/A FR-HEL-1.5K MR-J4-70GF/B/A MR-J4-100GF/B/A FR-HEL-2.2K MR-J4-200GF/B/A FR-HEL-3.7K MR-J4-350GF/B/A FR-HEL-7.5K MR-J4-500GF/B/A FR-HEL-11K MR-J4-700GF/B/A FR-HEL-15K MR-J4-11KGF/B/A MR-J4-15KGF/B/A FR-HEL-22K MR-J4-22KGF/B/A FR-HEL-30K MR-J4-60GF4/B4/A4 FR-HEL-H1.5K MR-J4-100GF4/B4/A4 FR-HEL-H2.2K

MR-J4-200GF4/B4/A4 FR-HEL-H3.7K MR-J4-350GF4/B4/A4 FR-HEL-H7.5K MR-J4-500GF4/B4/A4 FR-HEL-H11K MR-J4-700GF4/B4/A4 FR-HEL-H15K MR-J4-11KGF4/B4/A4 MR-J4-15KGF4/B4/A4 FR-HEL-H22K MR-J4-22KGF4/B4/A4 FR-HEL-H30K

E

A

F

Resistance regeneration converter unit model

Power factor improving

B

Drive unit model

DC reactor model Fig.

MR-J4-DU30KB/A MR-DCL30K MR-J4-DU37KB/A MR-DCL37K MR-J4-DU30KB4/A4 MR-DCL30K-4 MR-J4-DU37KB4/A4 MR-DCL37K-4 MR-J4-DU45KB4/A4 MR-DCL45K-4 MR-J4-DU55KB4/A4 MR-DCL55K-4

MR-CR55K

C

G

MR-CR55K4

D

Connections

Servo amplifier

Resistance regeneration converter unit

FR-HEL-(H)

MR-DCL

P3

P1

(Note 2)

(Note 1)

P4

P2

5 m or shorter

5 m or shorter

Notes: 1. Disconnect a short-circuit bar between P3 and P4 when using the power factor improving DC reactor. 2. Disconnect a short-circuit bar between P1 and P2 when using the power factor improving DC reactor.

Dimensions

D or shorter (Note 2)

2-d mounting hole (Note 1)

P P1

A

Terminal screw size

Variable dimensions [mm]

Wire size (Note 3) [mm 2 ]

Mass [kg]

Model

W W1

H

D d

H±2

FR-HEL-0.4K

70 60 71 61 M4 0.4 M4

2 (AWG 14) 2 (AWG 14) 2 (AWG 14) 2 (AWG 14)

FR-HEL-0.75K 85 FR-HEL-1.5K 85 FR-HEL-2.2K 85

74 74 74

81 81 81

61 M4 0.5 M4

70 M4 70 M4

0.8 0.9

M4 M4

W1 W±2

Notes: 1. Use this mounting hole for grounding. 2. This indicates the maximum dimension. The dimension varies depending on the bending degree of the input/output lines. 3. The wire size is applicable when 600 V grade heat-resistant polyvinyl chloride insulated wire (HIV wires) is used.