MELSERVO-J4
Options/Peripheral Equipment
Dynamic Brake Use the following optional external dynamic brake with the 9 kW or larger servo amplifiers.
GF-RJ GF
B
B-RJ
A
A-RJ
Without the external dynamic brake, a servo motor does not stop immediately at emergency stop and falls in free-run status, causing an accident such as machine collision, etc. Take measures to ensure safety on the entire system when not using the dynamic brake.
Servo amplifier/ drive unit model
Servo amplifier/ drive unit model
Dynamic brake model
Fig.
Dynamic brake model
Fig.
DBU-7K-4-2R0 DBU-11K-4 (Note 2)
DBU-7K-R6 DBU-11K (Note 1)
MR-J4-DU900B4
MR-J4-DU900B MR-J4-11KGF/B/A MR-J4-DU11KB MR-J4-15KGF/B/A MR-J4-DU15KB MR-J4-22KGF/B/A MR-J4-DU22KB
MR-J4-11KGF4/B4/A4 MR-J4-DU11KB4 MR-J4-15KGF4/B4/A4 MR-J4-DU15KB4 MR-J4-22KGF4/B4/A4 MR-J4-DU22KB4 MR-J4-DU30KB4/A4 MR-J4-DU37KB4/A4 MR-J4-DU45KB4/A4 MR-J4-DU55KB4/A4
DBU-11K-4
DBU-11K
B
A
DBU-15K
DBU-22K-4
DBU-22K-R1
MR-J4-DU30KB/A MR-J4-DU37KB/A DBU-37K-R1
C
DBU-55K-4-R5
Notes: 1. Use this dynamic brake when HG-JR801 or HG-JR903 servo motor is used. 2. Use this dynamic brake when HG-JR8014 or HG-JR9034 servo motor is used. Dimensions
[Unit: mm]
5
B E E
Wire size [mm 2 ] (Note 1) U, V, W Other than U, V, and W
Model
A B C D E F G Mass [kg]
Terminal arrangement
3.5 (AWG 12) 5.5 (AWG 10)
A
A
DBU-7K-R6 200 190 140 20 5 170 163.5 2
a b 13 14 U V W
2 (AWG 14)
Screw size: M3.5 Mounting screw size: M4
Screw size: M4
DBU-11K
DBU-15K DBU-22K-R1 250 238 150 25 6 235 228 6
5 100 D
G
2.3
D
F
C
2-ø7 mounting hole
228 26 26
260 10 10
TE1
a b 13 14
TE2 Screw size: M3.5
280
Wire size [mm 2 ] (Note 1) U, V, W Other than U, V, and W
U
V W
Mass [kg]
TE1 TE2
Screw size: M4 Mounting screw size: M6
Model
43
B
3.5 (AWG 12)
DBU-7K-4-2R0
51 25
7
73.75
15 2.3
6.7
2 (AWG 14)
200 150
195
25
DBU-11K-4 DBU-22K-4
5.5 (AWG 10)
210
170 TE1 TE2
15
15
178.5
179.5
2-ø10 mounting hole
10 10 370
U V W Screw size: M5 TE 1
30 330 30
TE 2
a b 13 14
Screw size: M3.5 Mounting screw size : M8
390
Wire size [mm 2 ] (Note 1) U, V, W Other than U, V, and W
Mass [kg]
Model
TE2 TE1
C
10
2.3 15
DBU-37K-R1
8
14 (AWG 6)
2 (AWG 14)
220
15
230 230 260
15
DBU-55K-4-R5 11
235
15
15
Notes: 1. The wire size is applicable when 600 V grade heat-resistant polyvinyl chloride insulated wire (HIV wires) is used.
5-67
Made with FlippingBook Annual report maker