MELSERVO-J4
Options/Peripheral Equipment
Dynamic Brake
GF-RJ GF
B
B-RJ
A
A-RJ
Servo Amplifiers Rotary Servo Motors Linear Servo Motors Direct Drive Motors Options/Peripheral Equipment Product List LVS/Wires Cautions
Connections
For MR-J4-DU900B(4), MR-J4-DU11KB(4), MR-J4-DU15KB(4), MR-J4-DU22KB(4)
For MR-J4-11KGF(4)/B(4)/A(4), MR-J4-15KGF(4)/B(4)/A(4), MR-J4-22KGF(4)/B(4)/A(4)
Drive unit malfunction RA1
Emergency stop switch
Ready on/off
MC
Malfunction RA1
Off
On
SK
MC
Power regeneration converter unit
(Note 4) Step-down transformer MCCB
SK
Drive unit L+ L
MC
Emergency stop switch
AC reactor
L+ L
L+ L-
MC
(Note 4) Step-down transformer
L1 L2 L3
Bus bar
U V W Servo motor M
U V W Servo motor M
Servo amplifier
MCCB
MC
V U W
U V W
L3 L2 L1
MC1 MC2
(Note 1)
L21 L11
(Note 1)
L11 L21
RA1
RA2
ALM
RA1 RA2
ALM
DB
(Note 2)
(Note 2)
DICOM DB DOCOM DICOM
24 V DC
DICOM
24 V DC
DOCOM
(Note 1)
SD (Note 6) EM2
L11 L21
(Note 6)
EM2
Main circuit power supply
(Note 6)
(Note 6) Main circuit power supply
SD
(Note 3)
13 U
V W
(Note 3)
14
(Note 5)
(Note 1)
b a
Dynamic brake (DBU)
Dynamic brake (DBU) 13 U
V W
14
RA2
(Note 1)
(Note 5)
b a
Dynamic brake interlock
Dynamic brake interlock RA2
For MR-J4-DU30KB(4)/A(4) or larger
Resistance regeneration converter unit malfunction RA2
Drive unit malfunction RA1
Emergency stop switch
Ready on/off
SK M C
Resistance regeneration converter unit
(Note 4) Step-down transformer
Drive unit
L+ L
L+ L-
Bus bar
U V W Servo motor M
MC1 MC2
V U W
MCCB
MC
L1 L2 L3
(Note 1)
A1 R A3 R
L11 L21
ALM
24 V DC
(Note 2)
DICOM DB DOCOM DICOM
ALM DICOM DOCOM DICOM
24 V DC
A2 R
EM2
EM1
(Note 6)
(Note 6) Main circuit power supply
DOCOM
SD
(Note 1)
L11 L21
(Note 3)
Dynamic brake (DBU) 13 U
V W
14
(Note 1)
a
Dynamic brake interlock RA3
b
Notes: 1. Install an overcurrent protection device (molded-case circuit breaker, fuse, etc.) to protect the branch circuit. 2. Validate DB (Dynamic brake interlock) with [Pr. PD07] to [Pr. PD09] for MR-J4-B/MR-J4-B4/MR-J4-DU_B/MR-J4-DU_B4. 3. The terminals 13 and 14 are normally opened outputs. If the dynamic brake is welded, the terminals 13 and 14 will be opened. Thus, create an external sequence circuit that SON (Servo-on) does not turn on when the terminals 13 and 14 are opened. 4. A step-down transformer is required if the servo amplifier, power regeneration converter unit, or resistance regeneration converter unit is in 400 V class, and coil voltage of the magnetic contactor is in 200 V class. 5. When using DBU-7K-4-2R0, DBU-11K-4 or DBU-22K-4, the power supply voltage must be between 1-phase 380 V AC and 463 V AC, 50 Hz/60 Hz. Refer to relevant Servo Amplifier Instruction Manual for details. 6. To prevent an unexpected restart of the servo amplifier, create a circuit to turn off EM2 (Forced stop 2) when the main circuit power is turned off.
5-68
Made with FlippingBook Annual report maker