SE Modicon M580 Brochure
Modicon M580 automation platform Modicon M580 Safety redundant processors
Selection guide (continued)
Modicon M580 automation platform
BMEH582040S + BMEP58CPROS3 mandatory coprocessor (1)
BMEH584040S + BMEP58CPROS3 mandatory coprocessor (1)
BMEH586040S + BMEP58CPROS3 mandatory coprocessor (1)
1
1
+
+
+
2
2
Racks
Local racks (main + extension)
1 8
16
31
Remote I/O drops (2) Discrete I/O channels
Local X80 I/O (3) (4)
Safe discrete I/O channels Analog I/O channels Safe analog I/O channels Application-specific channels (5)
Not supported
3
3
Combined Local and Remote X80 I/O (4)
16384
31744 11408
Discrete I/O channels
8192 2944 2048
5888 4096 1088
Safe discrete I/O channels
7936 2108 1116
Analog I/O channels
Safe analog I/O channels
544 288
4
4
576
Application-specific channels (5)
Distributed equipment (DIO, CSIO)
EtherNet/IP or Modbus TCP devices (scanned by CPU)
61
436
436
EtherNet/IP or Modbus TCP devices (scanned by CPU and Ethernet modules)
BMENOC301/ BMENOC311
317
CIP safety devices (scanned by CPU)
– (9)
Integrated communication ports
Ethernet service port (RJ45)
Engineering and Maintenance console (EcoStruxure Control Expert, Web browser, external tools), HMI, SCADA, Distributed equipment (DIO)
Ethernet device network dual ports (RJ45) - RSTP
RIO network (RIO/DIO scanner)
5
5
USB type mini B port
Programming port for Engineering Console (EcoStruxure Control Expert)
Communication
Ethernet networks
Cumulative max number of Ethernet networks modules
BMENOC/BMENOP/ BMENOR
2
4
EtherNet/IP and Modbus TCP
EtherNet/IP and Modbus TCP module BMENOC0301
2 2 2 2 2 2
3 3
FactoryCast IP Forwarding
FactoryCast module Ethernet control router
BMENOC0311 BMENOC0321 BMENOP0300 BMENUA0100
IEC 61850
IEC 61850 module OPC UA module
3
6
6
OPC UA
DNP3 NET / IEC 60870-5-104 DNP3 Serial / IEC 60870-5-101
Advanced RTU module
BMENOR2200H (6) BMXNOR0200H
4
RTU module
– (7) – (9) 4 (8)
Global Data AS-Interface
Global Data module AS-Interface module Serial link module CANopen module PROFIBUS DP module Program process (MB)
BMXNGD0100 BMXEIA0100 BMXNOM0200 BMECXM0100 PMEPXM0100
8 (8)
Each BMXNOM0200 channel counts as an application-specific channel (10)
Serial Link (Modbus and Character)
7
7
– (9)
CANopen
PROFIBUS DP
2 8 2
6
10 64 16
Internal memory capacity
16
Program safe (MB) Data process (KB)
4
768 512
2048 1024
Up to 64MB (11)
Data safe (KB)
1024
8
8
Data storage (GB)
4
40 30
50 40
No. of K instructions executed per ms
100% Boolean (Kinstr/ms)
10
65% Boolean + 35% fixed arithmetic (Kinstr/ms)
7.5 No
Product compatibility with Quantum
Support of Quantum Ethernet I/O (QEIO) and LL984 Editor
Yes
References
BMEH582040S
BMEH584040S
BMEH586040S
Pages
3/13
(1) The mandatory coprocessor must be ordered separately. (2) A Remote I/O drop can be either a X80 RIO Drop (RIO) or Quantum Ethernet I/O drop (QEIO). One X80 RIO Drop can support up to 2 racks (via X-bus extension). (3) Local X80 I/O are localized in local racks (main or extension). Redundant controllers do not not support Local X80 IO. (4) Maximum number of I/O channels (Discrete, Safe Discrete, Analog and Safe Analog) as well as application-specific channels is not cumulative. (5) Application-specific channels include counters, time-stamping, SSI encoder, Motion control, Serial and Frequency input modules. (6) Maximum number of BMENOR modules is not cumulative with other Ethernet network modules. (7) Not supported with safety controllers. (8) Only supported in Remote I/O drops : 2 per drop and with a maximum of 16 BMXEIA0100 modules. (9) Not supported with safety redundant controllers. (10) Only supported in Remote I/O drops. (11) BMEH586040S CPU features a global memory pool of 64 Mbytes for Program process (non-safe), Data process (non-safe non-retain data only), Program safe, and Data safe.
9
9
10
10
More technical Information on www.se.com
More technical Information on www.se.com
3/3 3/4
3/3 3/5
Made with FlippingBook flipbook maker