SE Modicon M580 Brochure

Modicon M580 automation platform Safety architectures Example of a safety complex architecture

References

References (1) Modicon M580 Safety standalone processors Memory capacity

Control Network Modicon M580 Safety as Safety Instrumented System (SIS)

Modicon M580 as Basic Process Control System (BPCS)

1

5

1

3

4

Maximum number of networks 2 Ethernet networks

Device ports

SERVICE port

Item (2)

Reference

Weight kg /lb

EcoStruxure Control Expert

1 BMEP582040S

2/8 MB integrated (safety/non-safety memory program) 4/16 MB integrated (safety/non-safety memory program) 16/64 MB integrated (safety/non-safety memory program)

2 RIO/DIO 1

0.849/ 1.872

Ethernet

Ethernet

5

4

Modicon X80 safety drop

Modicon X80 drop

2

1 BMEP584040S

4 Ethernet networks

2 RIO/DIO 1

0.849/ 1.872

5

4

Modicon X80 safety drop

Modicon X80 drop

1 BMEP586040S

4 Ethernet networks

2 RIO/DIO 1

0.849/ 1.872

STB I/O island

3

Field Safety instrumentation

Field instrumentation

Modicon M580 Safety

Modicon M580 Safety redundant processors Memory capacity

Maximum number of networks 2 Ethernet networks

Device ports

SERVICE port

Item (2)

Reference

Weight kg /lb

Control Network

5

1

3

4

EcoStruxure Control Expert

4

2 BMEH582040S

8 MB integrated (memory program)

2 RIO/DIO 1

0.849/ 1.872

Ethernet

5

4

2 BMEH584040S

16 MB integrated (memory program)

4 Ethernet networks

2 RIO/DIO 1

0.849/ 1.872

Modicon X80 drop

Modicon X80 drop

5

2 BMEH586040S

64 MB integrated (memory program)

4 Ethernet networks

2 RIO/DIO 1

0.849/ 1.872

5

4

5

4

Modicon X80 drop

Modicon X80 drop

STB I/O island

Modicon M580 Safety mandatory coprocessor Reference

Field Safety instrumentation

Field instrumentation

Item (2)

Weight kg /lb

6

BMEP58CPROS3

3

0.849/ 1.872

Modicon M580 Safety high availability architecture

Control Network

5

2

3

5

2

3

EcoStruxure Control Expert

(1) For additional characteristics, see our website. (2) 3.3 V c and 24 V c rack voltages for powering modules in the Modicon X80 I/O rack.

Modicon M580 Primary CPU

Modicon M580 Standby CPU

7

Remote Terminal Unit (RTU)

5

4

Modicon X80 drop

Time stamping (ERT)

Modicon switch

5

4

Optic Fiber converter

Modicon switch

8

Altivar Process Drive

Modicon X80 drop

Field Safety instru mentation

Modbus Serial Link

Energy monitoring

Field instrumentation HART device

9

10

Processors: page 2/2

Modicon M580 modules for severe environments: page 6/2

5/25