Square D Digest 179
Harmony™ Level, Pump, Speed, Frequency, and Temp. Control Relays
Control and Measurement Relays
Refer to Catalog DIA5ED2160501EN
www.se.com/us
Harmony™ Level Control Relays and Harmony™ Pump Control Relays Harmony level control relays control one or two levels with fill or empty function. The settings are protected by a sealable cover, control status is indicated by an LED, and they are DIN rail mountable. RM35LM is designed to control levels of conductive liquid, and RM35LV is designed to control levels of other materials. Application examples for RM35LM: Application examples for RM35LV: • Detecting pump seal failures • Liquids in the food-processing industry: milk, beer, coffee, etc. • Chemically pure water • Spring, town, industrial and sea water • Metallic salt, acid or base solutions • Liquid fertilizers • Non-concentrated alcohol (<40%) • Fuels, liquid gasses (inflammable) • Oil, concentrated alcohol (>40%) • Ethylene, glycol, paraffin, varnish and paints
RM35LM33MW
RM35LV14MW
Table 20.132: Level Control Relays Time Delay on Crossing the Threshold Function
Measurement Ranges
Catalog Number
Output Relay Supply Voltage 50/60Hz
250–5k 5k–100k 50k–1M
Detection by resistive probes Detection by discrete sensors
2C/O, 5A
RM35LM33MW
0.1–5 seconds, 0+10%
24–240 Vac/Vdc
1C/O, 5A
— RM35LV14MW
Table 20.133: Electrode Holders Description
Catalog Number
Material
RM79696006
Electrode for use up to 662°F (350°C)
Stainless steel isolated by ceramic
RM79696006
Pump Control Relay Harmony pump control relay RM35BA10 can operate on a single-phase or 3-phase supply. It incorporates three functions in a signal unit: • Over and under current measurement • Single or three phase • Phase presence control It has two operating modes which are designed to control a pump via two external signal inputs (Y1 Y2). These two signals are controlled by volt-free contacts. Control inputs Y1 and Y2 can be connected to: • Level sensor • Pressure sensor • Level relay • Push button Table 20.134: Pump Control Relay Description Current Range Controlled Supply Voltage Output Catalog Number
208–480 Vac, 3 phase
Pump Control Relay
1–10A
1C/O5A
RM35BA10
230, single-phase
Approvals for Harmony Level Control and Pump Control Relays
File: E173076 CNN:NRNT, NRNT7
CE 73/23/EEC andEMC89/ 336/EEC
GL, C-Tick, GOST, RoHS
File: 248382 Class: 3211 07
Approximate Dimensions (mm/in.) RM35LM33MW, RM35LV14MW
RM35BA10
35/ 1.38
72/ 2.83
35/ 1.38
72/ 2.83
E1
L1 L2 L3
20 RELAYS AND TIMERS
> I
54 .3
< I
90/ 3.54
Def. Un R
90/
2.8
2.8
Y1 Y2 12 11 14
0.11
0.11
76/ 2.99 72.5/ 2.85
76/ 2.99 72.5/ 2.85
20-55
© 2024 Schneider Electric All Rights Reserved