Square D Digest 179
9002A Heavy Duty Industrial
Foot Switches
Class 9002
www.se.com/us
Table 19.235: Foot Switch Catalog Numbers [1]
Fully Shielded with Oversized Pedal Shield, Side Shields and Safety Door Catalog Number
With Oversized Pedal Shield and Side Shields Catalog Number
WithPedal Shieldand Side Shields
UNSHIELDED (See Warning note [2] )
Description
Features
Catalog Number
Catalog Number
Single Pole [3] Double Throw TwoPole [3] Double Throw TwoStage [3] (One Pole Each Stage) Table 1 FourStage [3] (One Pole Each Stage) Table 2
Spring Return With Mechanical Latch Spring Return With Mechanical Latch
AW117 —
AW132 — AW133 — AW134 — —
AW2 AW7 AW14 AW15
AW1 — AW13 —
AW124 [4] —
Spring Return With Mechanical Latch in 1st Stage With Mechanical Latch in 2nd Stage
AW119 — —
AW5 — —
AW6 AW9
Spring Return
AW123
—
—
AW21
Single Pole Single Throw
Maintained Contact—Push On/Push Off
—
—
AW12
AW11
Replacement Cover Assembly
AC8 [5]
—
—
—
—
File: E78403 CCN: NKCR
File: LR25490 Class: 3211–03
For replacement parts for Class 9002 Type AW: See instruction bulletin 65013-010-31. Also see Table 19.237 Contact Symbol—Two Stage, page 19-98 and Table 19.238 Contact Symbol—Four Stage, page 19-98. Approximate Dimensions
( 5 ) .3 4 Dia . Mtg . Holes 9
( 3 ) .3 4 Dia . Mtg . Holes 9
6 . 4 0 16 3
3.50 89
2 .8 7 7 3
3.50 89
5. 6 3 14 3
4 .50 114
5.8 1 14 7
1 . 2 5 3 2
5.8 1 14 8
6 . 6 2 Typ . 16 8
8.5 6 2 1 6
11 . 1 3 2 83
3 / 4 14 P i p e T a p
2 .9 4 7 5
6 . 2 6 1 59
2 .90 7 4
5. 7 3 146
.9 4 2 4
.9 4 2 4
.38 1 0
4 . 6 0 11 7
5.0 2 1 2 8
1 .8 4 4 7
Types AW1, AW5, AW11, AW13 and AW21
( 5 ) . 34 Dia . Mtg . Holes 9
8.5 6 2 1 7
3 / 4 14 P i p e T a p
Types AW117, AW119, AW123, AW124 Types AW132, AW133 and AW134 (without safety door)
5. 3 8 13 7
3 .50 89
INTERFACE
1 . 44 3 7
19 PUSH BUTTONS AND OPERATOR
.9 4 2 4
4 .8 4 1 2 3
6 .8 7 1 7 4
3/4-14 NPT
9.00 22 9
Types AW2, AW6, AW12, AW14 and AW22 Dual Dime nsions: INCHES Millimeters
When ordering, add prefix “9002” to the catalog number.
[1]
[2] WARNING: These foot switches must not be used to operate machines or equipment where the possibility of operator injury exists. Typical uses include Emergency Stop functions, “Dead Man” controls, signal functions (lights, bells, etc.). [3] A single pole snap switch that contains two double break contact elements (1 N.O. and 1 N.C.) must be used on circuits of same polarity. A double pole snap switch contains two electrically separated sets of contact elements allowing use on circuits of opposite polarity. Each set that contains two double break contact elements (1 N.O. and 1 N.C.) must be used on circuits of same polarity. [4] 2 N.O. and 2 N.C. isolated, direct acting contacts. [5] For replacement cover drilled to accept latch. For Series C foot switches order AC9. No replacement cover available for Series A or B devices drilled to accept latch. AC8 is spring return only.
19-97
© 2024 Schneider Electric All Rights Reserved
Made with FlippingBook Ebook Creator