Square D Digest 179
TeSys™ Giga Contactors Refer to Catalog MKTED210011EN
Contactor Accessories
www.se.com/us
Flexible Terminal Extensions
Flexible connecting bars to connect TeSys Giga High power contactors with MCCBs mounted in the same plane and orientation. These bars can be used along with Advanced or Standard version contactors. They help to get a quick and easy connection
between contactor and MCCB with saving in installation time. Table 17.60: Flexible Terminal Extensions for MCCBs Description Compatible with Contactors To connect with PowerPacT ™ MCCB
Quantity Set of
Reference LA9G3111 LA9G3112 LA9G3113
H-J Frame 3P, GV5PB L Frame 3P, GV6PB
LC1G115...LC1G225 LC1G265...LC1G500 LC1G630...LC1G800
3 3 3
Flexible terminal extensions 3–pole
PFrame3P
LA9G3111
Auxiliary Contact Modules
Auxiliary contacts give an indication of the contactor status. They can be used for remote visual signaling, alarming, electrical locking, relay activation, and others. Each contactor is equipped with 1 NO (normally open) and 1 NC (normally closed)
auxiliary contact block as standard. Mechanically linked mirror contacts
The NC (normally closed) contact of the auxiliary contact block is a mirror contact in conformity to IEC 60947–5–1. It is mechanically linked to reliably represent the state of the main power contacts and wherever auxiliary contact state reliability is essential. The NC contact of the auxiliary contact cannot be closed at the same time as a normally open power contact. Contact module compatibility TeSys™ Giga auxiliary contact module is compatible with a range of TeSys Giga contactors. Each TeSys Giga contactor can be equipped with up to four auxiliary contact modules. Table 17.61: Electrical Characteristics Characteristics Rated thermal current (A) 10 Minimum load 1mAat17VDC Contact reliability Failure rate <10 Type of connections: • Push-In Table 17.62: Auxiliary Contact Modules Description Terminal type Types of contacts Sold in lots of Reference Auxiliary contact module Push-In 1NO+1NC 1 LAG8N113P [29] 2NO 1 LAG8N203P
LAG8N113
17 CONTACTORS AND STARTERS-IEC
Connection Kits and Mechanical Interlock Table 17.63: Star-Delta (Wye Delta) Connection Kits Description Suitable for: For Line/Delta contactor
+ Star contactor
Reference LA9GQQ330 LA9GSQ330 LA9GSS330 LA9GTS330 LA9GTT330 LA9GSQ331 LA9GTS331
LC1G115/LC1G225 LC1G115/LC1G225 LC1G265/LC1G500 LC1G115/LC1G225 LC1G265/LC1G500 LC1G265/LC1G500 LC1G630/LC1G800 LC1G265/LC1G500 LC1G630/LC1G800 LC1G630/LC1G800 LC1G265/LC1G500 LC1G115/LC1G225 LC1G630/LC1G800 LC1G265/LC1G500
3-pole
Connection kit: bars for Line/Delta Star contactor assembly
3-pole (with cable memory kit)
NOTE: RE17RMMWS timer to be used for Star-Delta starter application. Table 17.64: Reverser Connection Kits Description Suitable for: Compatible with contactors
Reference LA9G3760 LA9G3761 LA9G3762
LC1G115/LC1G225 LC1G265/LC1G500 LC1G630/LC1G800
Connection kit: bars for reverser contactor assembly
3-pole
Table 17.65: Changeover Connection Kits Description Suitable for:
Compatible with contactors LC1G115/LC1G225 LC1G265/LC1G500 LC1G630/LC1G800 LC1G115/LC1G225 LC1G265/LC1G500 LC1G630/LC1G800
Reference LA9G3750 LA9G3751 LA9G3752 LA9G4750 LA9G4751 LA9G4752
3-pole
Connection kit: bars for changeover contactor assembly
4-pole
[29] Always supplied with TeSys™ Giga LC1G contactors (fitted to the right side lateral face).
17-23
© 2024 Schneider Electric All Rights Reserved