Square D Digest 179

TeSys Selection Overview

Solutions that enhance machine intelligence Refer to Catalog MKTED210011EN

www.se.com/us

TeSys Control Solutions TeSys offers solutions for a variety of common control applications, including small to large loads, motor and non-motor loads, in various forms to meet customers specific needs. Basic solutions offer traditional approaches that meet compact, cost-effective, and large HP applications. TeSys also equips OEMs and System Integrators with EcoStruxure Machine connected product solutions that are IoT ready offers to help enhance the intelligence of machinery and equipment, helping to recognize and address potential issues before stoppage and decrease unplanned downtime.

Table 17.1: Solutions that enhance machine intelligence

Solution 3 — TeSys Ultra (Type E self-protected) using Multi-function trip unit & communication module or using pre-trip alarm function module

Solution 5 — TeSys GV4PB, GV5PB, GV6PB with SDx Module

Solution 4 — TeSys T overload relay

Solution 1 — TeSys™ island as group motor

Solution 2 — TeSys island with individual protection

17 CONTACTORS AND STARTERS-IEC

Ideal for adding intelligence using a simple NO/NC pre-trip alarm contact — Use of PLC to receive/ interpret data not required. Pre-trip alarm NO/NC contact alerts prior to trip, enabling proactive actions to minimize downtime or alert operators GV4PB, GV5PB, GV6PB

Ideal for panels with multiple loads . Single bus coupler serves as connection to PLC, manages logic and configuration for starters. See load, device and system performance. Set alarms to anticipate maintenance and optimize performance. Circuit breaker or fuse protection group TeSys island load management system with or without TeSys Deca Manual Motor Controllers

Ideal for panels with multiple loads . Single bus coupler serves as connection to PLC, manages logic and configuration for starters. See load, device and system performance. Set alarms to anticipate maintenance and optimize performance.

Ideal for panels with one or two motors . Each starter communicates directly to PLC. See load performance. Set alarms to anticipate maintenance and optimize performance. TeSys Ultra (applied as Type E self protected), using advanced trip unit/ function modules

Ideal for largerHP . Each overload relay communicates directly to PLC. See load performance. Set alarms to anticipate maintenance and optimize performance.

Best Practice Scenario

Benefits

Breaker or fuse

Circuit Protection

Circuit breaker or fuse

TeSys Deca or Giga contactors TeSys T overload relay

TeSys Deca or Giga contactor (included in GV*PB)

Motor Control Motor Overload Protection LoadTypes MaxHP480V

TeSys island load management system Motor, resistive/non-inductive, isolation

Motor, resistive/non-inductive, isolation

Motor loads only

Motor loads only

Motor loads only

500 HP (up to 810 amps)

450 HP (up to 520 amps)

40HP

40HP

20HP

basic 5 kA up to high 50 kA (with GV) high, to 100 kA

High, to 65 kA

Depends on configuration Depends on configuration

SCCR

Device status/performance Load performance including alarms Voltage, Energy & Power Ethernet IP, Modbus TCP, Profinet, Profibus

Device status/performance Load performance including alarms Voltage, Energy & Power Ethernet IP, Modbus TCP, Profinet, Profibus

Load performance including alarms Voltage & Power Modbus™, CANopen, DeviceNet™, Profibus™, Ethernet/IP, and Modbus/ TCP

Pre-trip alarm (via NO/NC contact)

Load performance including alarms

Available data

Modbus™, CANopen, DeviceNet™, Profibus™

None

Communication

17-2

© 2024 Schneider Electric All Rights Reserved