Square D Digest 179
Thermal Units
Thermal Unit Selection Thermal Unit Selection Tables
www.se.com/us
Thermal Unit Selection NOTE: For thermal unit selection tables for other devices including obsolete devices, consult the Customer Care Center at 1-888-778-2733.
Table 16.367: Thermal Unit Selection
Thermal Unit Selection Table Number Hand Reset Melting Alloy
Controller
Standard Trip (20)
QuickTrip (10)
SlowTrip (30)
Starter Type
Type
Series [1]
Class 2510 2512 8908
Size
Manual Starters FHP
43 [2]
F
A
FHP
—
—
Manual Starters (Small Enclosure)
[3] [3] [3] [3] [3] [3] [3] — — — [3] [3] [3] [3] [3] — — — — — — — — — — — — — — — — — — — — — — —
M–0 M–1 M–1P M–0 M–1 M–1P
1 1 1 2 2 2
72 72 72 73 73 73 — — — — — 74 74 — 75 — — 83 — 74 74 75 75 — — — — — — — — — — — — — — —
M, T
2510
A
Manual Starters (Large Enclosure) DC Magnetic Starters
2510 2511 2512 8925 7135 7136 7735 7736
M, T
A
C,D
65
— 1, 2 — 3 — 4 — 5
E F G
9
10 12
EC&MCrane Control Product
A (8536 only)
8536 8904 [4] (Starter InOwn Enclosure)
17 [2]
B, C 00
A, B
SA SB
00
13 13 13 41 56 18 54 49 59 21 66 15 67
A A A A A A A
0 1
8933 8998 8999 (Model 3 Control Center) I-LINE ® andQMB Motor Starter Centers
16 NEMA AND DEFINITE PURPOSE CONTACTORS AND STARTERS
SC
1P
SD SE SF SG SH SC
2 3 4 5 5 6
76 [5]
134 [3][5]
B [6] A, B
1Fusible
A
AC Magnetic Starters (Small Enclosure)
1 Circuit Breaker
2Fusible
SD
A
8998 8999 (Model 4 Control Center)
58 [7]
2 Circuit Breaker 3 Small Enclosure 3 Large Enclosure
76 [5] 76 [5]
134 [3][5] 133 [3][5]
16
SE SF SG SH
A A A A A A A A A B A C A
68 [7]
4 5 6 1 2 3 4 5
61 24 20
109 104 110 111 112 113 103 114 135 145 146
SC [8] SD [8] SE [8] SF [8] SG [8] SH [8]
1COMPAC6
8998 (Model 5 and Model 6 MCCs)
5CT
6
20–30A
8911
DPSG
40A 50A
(table continued on the next page) NOTE: For thermal unit selection tables for other devices, including obsolete devices, consult the Customer Care Center at 1-888-778-2733.
[1] Series letters listed refer to the marking on the nameplate of the basic openstyle starter. When the starter comes in a controller containing other devices, the controller may have a different series letter marked on the enclosure nameplate. [2] Type A thermal units for full-load currents lower than those listed in this table are available. For complete information, consult Customer Care Center at 1-888-778-2733. [3] This device will accept Type SB slow trip (Class 30) thermal units. For selection, see page 16-134. [4] Small enclosure tables apply for Class8904 non-combination and non-reversing starters. For combination and reversing Class8904 starters, refer to the large enclosure selections, index above. [5] FormY81 must be specified to use quick trip (Class 10) or slow trip (Class 30) thermal units on Size 3 starters. [6] Divide the motor FLC by 60, and use this quotient to select the appropriate thermal units. [7] Use for autotransformer starters (fusible and circuit breaker). [8] Refers to the Type number of the starter in the MCC, not the Type number of the MCC.
16-135
© 2024 Schneider Electric All Rights Reserved