Square D Digest 179
Accessories
Motor Logic™ Solid-State Overload Relay Class 9999, 9065 / Refer to Catalog 9065CT9701
www.se.com/us
Motor Logic—Class 9999 Isolated Auxiliary Contacts for Motor Logic™ Overload Relays
Overload relay auxiliary contacts are available factory installed or in kit form for field installation on Motor Logic overload relays. These contacts may be used for isolated alarm contact applications. DIN Adapter The DIN adapter provides a method to mount the Motor Logic overload relay to a 35 mm DINrail. Lug-Lug and Lug-Extender Kits A Class 9999 LL0 Lug-Lug Kit can be field installed on separately mounted overload relays. The standard Size 00B, 00C, 0, and 1 Class 9065 Type SS and SF overload relays are supplied without lugs. A Class 9999 LB0 Lug-Extender Kit is designed for Size 00B, 00C, 0, and 1 Retrofit Starter Applications. This kit allows the lugs to be in the same location as the Class 9065 melting alloy overload relay, eliminating the need for additional wire length. Remote Reset Module The Remote Reset Module can be easily field installed on solid-state overload relays. This module will allow the overload relay to be reset from a remote location. Table 16.349: Remote Reset Module For Use With Parts Kit Description Cat. No. Class & Type NEMASize [9] 8536SA–SJ 00B through 7 Remote Reset Module 9999RR04 [10] 9065SF, ST 00B through 7 8536SE–SF 3and4 Top Mounting Bracket 9999RB34 [10][11] 9065SF, ST 3and4 Power Pole Adders One single- or double-circuit power pole kit can be field added to a basic two- or three pole Type S contactor or starter Sizes 0, 1 and 2, or lighting contactors 30–60 A. See Table 16.350 for selection. The ratings for these power pole adders correspond to the NEMA contact ratings found on page 16-123. A two- or three-pole contactor or starter accepts only one single- or double-circuit unit. A power pole cannot be used on four- or five-pole devices, or on devices that are mechanically interlocked. When adding a power pole to a Size 0 or 1 device, remove the return springs according to the instructions that come with the device. When adding a power pole to a Size 2 or 60 A device, a coil change is required. Select a four- or five-pole coil from page 16-123, or specify Form Y118 as noted in the footnote below. When adding Size 0–2 power pole kits to a Size 3–7 or 100–800 A device, an adapter bracket is required. The Class 9999 Types SB6–SB15 power pole kits are suitable for copper wire only. Table 16.350: Power Pole Adders—Selection For Use With Power Pole Adder Kit Type Size Description Class 9999 Type SB, SC, and SM 0, 1, and 30 A One N.O. power pole adder 9999SB6 SD 2 — SP 60A — SB, SC, and SM 0, 1, and 30 A One N.C. power pole adder — SD 2 9999SB12 [12] SP 60A — SB, SC, and SM 0, 1, and 30 A One N.O. and one N.C. power pole adder — SD 2 9999SB13 [12] SP 60A — SB, SC, and SM 0, 1, and 30 A Two N.O. power pole adders 9999SB9 SD 2 — SP 60A — SB, SC, and SM 0, 1, and 30 A Two N.C. power pole adders — SD 2 9999SB15 [12] SP 60A — SE–SJ and SQ–SZ and SJ 3–7 and 100–800A Adapter bracket —
Table 16.346: Isolated Auxiliary Contacts for Motor Logic™ Overload Relays For Use With PartsKit Description Cat. No. Class & Type NEMASize [9] 8536SA–SJ 00B through 7 N.O. or N.C. 16 NEMA AND DEFINITE PURPOSE CONTACTORS AND STARTERS Table 16.347: DIN Adapter (Separate Mount Only) For Use With PartsKit Description Cat. No. Cat.No. NEMASize [9] 9065SF 00B, 00C, 0, and 1 DIN Adapter 9999DA01 Table 16.348: Lug-Lug and Lug-Extender Kits For Use With PartsKit Description Cat.No. Cat. No. NEMASize [9] 9065SF 00B, 00C, 0, and1 Lug-Lug Kit for separate mounting 9999LL0 Auxiliary Contact (Field Convertible) 9999A C04 9065SF, ST 00B through 7
Lug-Extender Kit for retrofitting existing NEMA S starters
00B, 00C, 0, and1
9065SF
9999LB0
Class 9999 Type SB6 Single Power Pole Adder
Class 9999 Type SB9 Double Power Pole Adder
[9] Size 00B and 00C are not actual NEMA sizes. These designations are used to differentiate the lower FLA of these devices from the NEMA Size 00 Motor Logic solid-state overload relay. [10] 120 Vac power required. [11] For mounting the remote reset module on the top of the overload relay. [12] To order a Size 2 or 60 A power pole kit complete with a new starter coil, specify FormY118, the voltage, and the frequency.
16-130
© 2024 Schneider Electric All Rights Reserved
Made with FlippingBook Ebook Creator