Solid-State TeSys™ D Overload Relays for Type S Starters Sizes 00–1, Non-Reversing (Classes 8536, 8538, 8539) and Reversing (Classes 8736, 8738 and 8739) NOTE: • Field installed only : The LR9D Overload Relay cannot be factory installed, it must be purchased separately and field installed. • Single-phase motor applications : When using the LR9D with a single-phase motor, you must purchase the 3-pole starter to accommodate looping of the motor leads. Current Setting Overload Relay Catalog Number (sold separately) Range Amperes Trip Class 5/10/20/30 Dip Switch Selectable 0.1–0.5A LR9D01 0.4–2A LR9D02 1.6–8A LR9D08 6.4–32A LR9D32 Table 16.317: TeSys™ D Overload Relays for Sizes 00–1 Type S Starters, Non Reversing and Reversing, Classes 8536, 8538, 8539, 8736, 8738, and 8739
Class20 without Single Phase Sensitivity Screw Termination
Class20 without Single Phase Sensitivity Ring Tongue Connector
Class20 with Single-Phase Sensitivity Screw Termination
Class20 with Single-Phase Sensitivity Ring Tongue Connector
Factory Installed— Catalog Number Suffix (CP1List)
Current Setting Range Amperes
0.40–0.63
LRD04L LRD05L LRD06L LRD07L LRD08L LRD10L LRD12L LRD14L LRD16L LRD21L LRD22L LRD32L
LR3D04L LR3D05L LR3D06L LR3D07L LR3D08L LR3D10L LR3D12L LR3D14L LR3D16L LR3D21L LR3D22L LR3D32L
LRD04L6 LRD05L6 LRD06L6 LRD07L6 LRD08L6 LRD10L6 LRD12L6 LRD14L6 LRD16L6 LRD21L6 LRD22L6 LRD32L6
LR3D04L6 LR3D05L6 LR3D06L6 LR3D07L6 LR3D08L6 LR3D10L6 LR3D12L6 LR3D14L6 LR3D16L6 LR3D21L6 LR3D22L6 LR3D32L6
04 05 06 07 08 10 12 14 16 21 22 32
0.63–1 1–1.6 1.6–2.5 2.5–4 5.5–8 7–10 9–13 12–18 17–24 23–32 4–6
16 NEMA AND DEFINITE PURPOSE CONTACTORS AND STARTERS
NOTE: For tripping class 10: • With screw termination, remove the L from the end of the above part number (for example, LRD32 is a class 10 bimetallic overload relay with a 23–32 A setting range). • With a ring tongue connector, change the L6 to 6 at the end of the above part number (for example, LRD326 is a class 10 bimetallic overload relay with a 23– 32 A setting range). TeSys™ T Factory Modifications (Forms) Table 16.319: TeSys™ T Motor Management System Modifications H6xx or H7xx for use with Class 8536 and 8736 (Open Starters)
Table 16.318: Communication Codes Communication Network
Code
Modbus™ ProfiBus CANopen DeviceNet
2 3 4 5
Form Control Voltage
Range
Used on Size
100–240 Vac H61X [18]
24Vdc H71X [18] H72X [18] H73X [18] H75X [18] H76X [18] H77X [18]
1 1
0.4–8A
Ethernet TCP/IP (communication protocols: Ethernet/IP™ and Modbus/TCP)
H62X [18] H63X [18] H65X [18] H66X [18] H67X [18]
1.35–27A 5.0–100A
6
2, 3
8–160 (CT 300:5 3 turns) 24–480 A (CT 300:5 1 turn) 48–960 A (CT 600:5 1 turn)
4 5 6
NOTES: • The product configurator must be used to order TeSys T open starters. • The auxiliary contact for the control of the starter coil has a maximum rating of 240 Vac.
[18] Where X is the communication option according to Table 16.318 Communication Codes, page 16-121 (for example, H612).
16-121