Full Voltage Contactors, Starters, and Overload Relays

Factory Modifications (Forms)

www.se.com/us

Class 8536 Table 16.311 Control Circuit, Full Voltage and Multi-Speed Controllers Only (cont'd.)

Classes 8502, 8536, 8538, 8539, 8702, 8736, 8738, 8739, 8810, 8811 and 8812

NEMASIZE

Enclosure Type

Classes Factory Modifications

Form FF4T

00

0 X X

1 X X

2 X X

3 X X

4 X X

5

6 X

7 X

X [13] X [13]

2 2

1 2

7&9

X X

1, 4, 4X, 12 [14]

F4F10T

— —

Additional Capacity (50 or 60 Hz) Two fuses in primary and one fuse in secondary 100 VA additional capacity 1, 4, 4X, 12

X [13] X [13] X [13] X [13] X [13] X [13]

X [13] X [13] X [13] X [13] X [13] X [13]

FF4T11 FF4T11 FF4T12 FF4T13 FF4T14 FF4T15

X X X X X X

X X X

X X X

X X X

X X

X

X

100 VA additional capacity [14] 200 VA additional capacity 300 VA additional capacity 400 VA additional capacity 500 VA additional capacity

7&9

— —

X [13] X [13] X [13] X [13]

1, 4, 4X, 12 1, 4, 4X, 12 1, 4, 4X, 12 1, 4, 4X, 12

X X

X X

X [13] X [13] X [13]

X [13] X [13] X [13]

X [13] X [13] X [13]

X [13] X [13]

X [13] X [13]

Selection of Control Circuit Transformers The standard primary/secondary voltages for control circuit transformers are indicated in . To order, select the desired device with the appropriate transformer Form designation. Then convert the previously selected voltage code (V●●) to reflect the desired primary/ secondary voltage for the transformer. The secondary voltage should equal the previously selected coil voltage of the device. Example: You have selected 8536SDG1V02S. V02S means that you need a coil voltage of 120-60/ 110-50 wired for separate control. You would like to add FormFF4T , with transformer voltages of 480 V primary, 120 V secondary, and solid-state overload relay protection with selectable Class 10/20 trip class—Form H30 . (The Form designations needed are FF4 , H30 , and T .) The new and complete Class, Type, voltage code, and Form number will be: Class Type Voltage Code Form [17] 8536 SDG1 V81 FF4H30T

Table 16.312: Marine Control Class Factory Modification

Enclosure Type

Form

8502 8536 8538 8539 8702 8736 8738 8739 8810 8941

12/3R 4/4X

Modification of standard device for use as marine control in accordance with UL508 [15]

M10

(stainless steel only)

16 NEMA AND DEFINITE PURPOSE CONTACTORS AND STARTERS

Table 16.313: Control Circuit Transformer Codes AC-Operated Devices With Control Transformers Voltage Code 60 Hz (Primary–Secondary)

120–12 [16] 120–24 [16] 208–120 240–24 [16] 240–120 277–120 480–24 [16]

V88 V89 V84 V82 V80 V85 V83 V81 V87 V86 V99

480–120 480–240 600–120 Specify

[13] Single primary voltage must be specified. [14] Not available for Sizes 6 and 7. [15] Not available for NEMA Sizes 0, 00, or 7. NEMA Sizes 00 and 0 cannot be used with marine controls. [16] 12 V coils are not available on Sizes 3–7. 24 V coils are not available on Sizes 4–7. [17] Specify Form numbers in alphabetical order. Each letter indicates the beginning of a new Form and may be followed by one or more numbers.