Square D Digest 179
Reversing Hoist, Type DPR Class 8965 / Refer to Catalog 8910CT9301
Reversing Definite Purpose Contactors
www.se.com/us
Class 8965 Type DPR reversing/hoist contactors are designed for the control of motors in hoists, overhead doors, small elevators, commercial laundry equipment, and other related products which use reversing motors. They are rated to perform in the short periods of jogging experienced in hoist service. The coils are designed to operate on line voltages of 85–110% of rated voltage, and are for applications at 50 or 60 Hz only. Coils are easily replaced with external base removed. Auxiliary contacts can easily be fieldadded to any Class 8965 reversing contactor. Type DPR contactors accept one auxiliary contact module with up to two isolated circuits per side (two modules per device). When auxiliary contacts are ordered separately, two modules are normally used for each device; one for forward, one for reverse.
8965DPR33V02 Hoist Contactor 600 Vac, 25 A DPR, Angled 16 NEMA AND DEFINITE PURPOSE CONTACTORS AND STARTERS
Table 16.265: Reversing/Hoist Contactors—600 Vac Maximum (replace ●●● with the voltage code)
Horsepower Ratings [1]
OpenType
No. of Poles
115V 1Ø
230V 1Ø 5 7-1/2 5 7-1/2
230V 3Ø
460/575V 3Ø
Type [2]
3-Pole Polyphase 4-Pole Polyphase
2 3 2 3
10 15 10 10
15 20 15 20
DPR33●●● DPR43●●● DPR34●●● DPR44●●●
Table 16.268: Coil Voltage Codes Volts, 60 Hz
Table 16.266: Auxiliary Contacts Separate Module [3] Description Class 9999 Type
Voltage Code
Volts, 50 Hz
24
24
V14 V02 V09 V04 V06 V07
120
110 220 440 550 —
1N.O. 1N.C. 1 N.O.–1 N.C. 2N.O.
D10 D01 D11 D20
208–240
277 480 600
Table 16.267: Factory Installed Description
Table 16.269: Approvals UL Component Recognized—File E42240, CCN NLDX CSA Certified—File LR25490, Class 3211 04
Form X1010 X0101 X1111 X2020
1 N.O. Each Side 1 N.C. Each Side
1 N.O.–1 N.C. Each Side
2 N.O. Each Side
Approximate Dimensions
6.87 174
3.37 86
3.07 78
3.76 (Fastons) 96 3.86 (Box Lugs) 98
3.98 101
3.72 95
3.19 81
5.87 149
Type DPR13 through DPR43
4.39 111.60 2.64 67.10
6.03 153.20
2.98 75.70
3.73 94.70
3.27 82.10
3.12 79.20
3.25 82.60
5.08 129.00
Type DPR14 through DPR44
[1] For rapid operation (jogging duty), use the next larger size contactor. [2] Replace the three bullets (●●●) in the catalog number with the coil voltage code. Refer to the standard voltage codes listed in Table 16.268. [3] Order two modules for Type DPR, one for each side.
16-100
© 2024 Schneider Electric All Rights Reserved
Made with FlippingBook Ebook Creator