Square D Digest 179
Full Voltage
Duplex AC Motor Controllers
Class 8941
www.se.com/us
Table 16.252: Type Fig.
A
B
C
D
E
F
G H
J
K
L
M
Knockouts
V
in. mm
in. mm
in. mm 6.67 169
in. mm 9.70 246
in. mm
in. mm
in. mm 7.00 178
in. mm 2.41 61
in. mm 3.00 76
in. mm Conduit
in. mm R
in. mm 1.41 36
S
T
NPD/E/F SSC SSD
2.41 61 0.5–0.75 1.25–1.5 0.5–0.75
39.05 992
13.73 349
33.05 839
37.93 963
3.00 76
2.5
1
NPG/J SSE/F XSE/F
49.00 1245
19.15 486
8.81 224
10.37 263
44.07 1119
47.88 1216
7.00 178
2.17 55
2.69 68
3.44 87
2.57 65 0.5–0.75
1.41 36
1–1.25 1–2.5
1–1.25 1.5–2
2.5
1
WC—S2 WD—S2 XC—S2 XD—S2 WE—S2 WF—S2 XE—S2 XF—S2 16 NEMA AND DEFINITE PURPOSE CONTACTORS AND STARTERS 1 38.50 978 19.00 483 1
2.12 54 0.5–0.75
7.29 185
9.39 239
34.00 864
37.38 949
7.00 178
2.18 55
2.13 54
2.13 54
1–1.25 1.5
0.5–0.75 —
1.5
1.50 38 1.50 38 N/A
56.50 1435 75.50 1892 82.50 2096 92.50 2350
23.00 584 22.00 559 36.00 914 34.00 864
8.23 209
10.33 262 17.55 446 23.25 591 23.25 591
52.00 1321 73.00 1854 80.00 2032 90.00 2286
55.38 1407 74.50 13 33.75 857 31.75 806
7.00 178
2.18 55
2.69 68 0.56 14
3.44 87
2.68 68 0.5–0.75
1–1.25 2–2.5
1–1.25 1.5–2
2
13.80 351 20.00 508 20.00 508
14.00 356 N/A
SSG XSG 1 XSH 2
N/A N/A N/A
N/A
N/A
N/A
16.50 419 N/A N/A N/A N/A N/A 16.50 419 N/A N/A N/A N/A N/A
N/A
N/A
N/A
XSJ
2
N/A N/A NOTE: Illustrations may not represent the actual enclosure. They are intended for dimensional information only. Dimensions: in. mm N/A N/A
Figure1
Figure2
Selection Duplex Motor Controllers are used to control two motors, and consist of two starters in a common enclosure. Two separate disconnect switches or circuit breakers with operators are included with all combination devices. Unless FormY68 is specified, an alternation circuit (a Class 8501 Type XO40 relay) is included, which alternately operates first one motor and then the other on each successive closing of a pilot device. Both motors will be energized should a second pilot device close. All devices incorporate a terminal block to simplify wiring of pilot devices A and B. Typical applications include pump motors where a second pump is required for peak demand periods yet alternation is desirable to equalize pump wear. Table 16.253: 3-Pole Polyphase—600 Vac Maximum (50–60 Hz) Non-Combination Type—Without Disconnect—With Electric Alternation (replace ●●● with the voltage code) (Devices require 6 thermal units. See Thermal Unit Selection, page 16-134.)
NEMA4/4X Watertight and Dusttight Enclosure Stainless Steel
NEMA12 (NEMA 3 and 3R) [1] Dusttight and Driptight Industrial Use Enclosure
NEMA1 General Purpose Enclosure
Maximum Rating EachMotor
OpenType
NEMA Size
Hp Polyphase
Voltage 200–230 460–575 200–230 460–575
Type [2]
Type [2]
Type [2]
Type [2]
3 5
0
NBG10●●● NBW10●●●
NBA10●●●
NBO10●●●
7.5 10
NCG20●●● NCW20●●●
NCA20●●●
NCO20●●●
1
[1] NEMA 12 enclosures can be field modified for outdoor applications. For details, refer to Class 9991 on page 16-113. [2] Replace the three bullets (●●●) in the catalog number with the coil voltage code. Refer to the standard voltage codes listed inTable 16.264.
16-96
© 2024 Schneider Electric All Rights Reserved
Made with FlippingBook Ebook Creator