Square D Digest 179
Lighting Contactors
Field Modifications
Class 8903 / Refer to Catalog 8903CT9701
www.se.com/us
Cover Mounted Control Units
Table 16.209: Mechanically Held
TYPELX
TYPES
Form No.
Description
400, 600, 800 A
30A
30A
60A
100A
200A
300A
Kit
Kit
Kit
Kit
Kit
Kit
Kit
Push Button (On-Off) NEMA 1 Enclosure NEMA 3R, 4 or 12 Enclosure Selector Switch (2 Position) NEMA 1 Enclosure NEMA 3R, 4 or 12 Enclosure Selector Switch (3 Position) NEMA 1 Enclosure (must include two wire control relay, FormR6 NEMA 3R, 4 or 12 Enclosure Two Wire Control Relay (FormR6) [40] 16 NEMA AND DEFINITE PURPOSE CONTACTORS AND STARTERS A3 C6 C R6
9001KA2 9999SA3 [39] 9001KA2 9999SA3 [39] 9001KN244 — 9001KN244 —
9001KA2 9999SA3 [39] 9001KA2 9999SA3 [39] 9001KN244 — 9001KN244 —
9001KA2 9999SA3 [39] 9001KA2 9999SA3 [39] 9001KN244 — 9001KN244 —
9001KA2 9999SA3 [39] 9001KA2 9999SA3 [39] 9001KN244 — 9001KN244 —
9001KA2 9999SA3 [39] 9001KA2 9999SA3 [39] 9001KN244 — 9001KN244 —
9999BLX —
[38]
9001KA2 9999SA3 [39]
9001KA2 9999SA3 [39] 9001KN244 — 9001KN244 —
9999BLX —
9001KN244 —
9999BLX 9999SC2
9001KN260 —
9001KN260 —
9001KN260 —
9001KN260 —
9001KN260 —
9001KN260 —
9001KN260 —
—
8501XO11
8501XO11
8501XO11
8501XO11
8501XO11
8501XO11
Table 16.210: Electrically Held
TYPEL
TYPES
Form No.
Description
400, 600, 800 A
30A
30A
60A
100A
200A
300A
Kit
Kit
Kit
Kit
Kit
Kit
Kit
Pilot Lights (Red and Green) NEMA 1 Enclosure NEMA 3R, 4 or 12 Enclosure Push Buttons [43] NEMA 1 Enclosure NEMA 3R, 4 or 12 Enclosure Selector Switch (2 Position) NEMA 1 Enclosure NEMA 3R, 4 or 12 Enclosure Selector Switch (3 Position) NEMA 1 Enclosure NEMA 3R, 4 or 12 Enclosure
[41] 9999SP14R 9999SP28R
[42] 9999SP28R 9999SP28R
[42] 9999SP28R 9999SP28R
— 9999SP28R
9999SP28R 9999SP28R
P1
9999SP28R 9999SP2R 9999SP28R
9999BLX 9999SA10 9999SA3 9999BLX 9999SC22
9999SA10
9999SA10
9999SA3
9999SA3
9999SA3
9999SA3
A12
9999SA3
9999SA3
9999SA3
9999SA3
9999SA3
9999SA3
9999SC22
9999SC22
9999SC22
9001KN244
9001KN244
9001KN244
C6
9001KN244
9001KN244
9001KN244
9001KN244
9001KN244
9001KN244
9001KN244
9999BLX 9999SC2
9999SC2
9999SC2
9999SC2
9999SC8
9999SC8
9999SC8
C
9999SC8
9999SC8
9999SC8
9999SC8
9999SC8
9999SC8
9999SC8
[38] No field installed kit available. [39] Mechanically held contactors need two distinct signals to operate. An N.O. contact block must be added to the Class 9999 Type SA3 push button kit.
[40] Form R6 available for 24 V, 120 V, 240 V and 277 V only. [41] 2- or 3-pole only. For 4- or 5-pole use Class 9999SP15R. [42] The coil voltage must be the same as the pilot light rating. Kit contains one (1) Class 9001, Type KP1R6 120 V/60 Hz red pilot light control unit. For other voltages, refer to the Class 9001, Type KP Control Section. [43] Requires holding circuit interlock for Type S or additional power pole on Type L devices.
16-82
© 2024 Schneider Electric All Rights Reserved
Made with FlippingBook Ebook Creator