Square D Digest 179
Lighting Contactors
Factory Modifications (Forms) Class 8903 / Refer to Catalog 8903CT9701
www.se.com/us
Factory Modifications (Forms)
Standard Equipment dimensions and enclosure construction may not apply when certain special features are added. Such cases should be referred to the factory with a complete description when precise dimensions are required.
NOTE: If a UL label is required, consult the Customer Care Center at 1-888-778-2733. Some Forms arenot ULListed.
Table 16.206: Lighting Contactor Forms (Factory Modifications)
Rating (A)
UsedOn
Description 16 NEMA AND DEFINITE PURPOSE CONTACTORS AND STARTERS On-Off push button (momentary contact)
NEMA Enclosure Type
Form Letter
Std.
Combo
Night Master 30–200A
400, 600, 800
30 Type L 30 60 100 200 300
Elec. Held
Mech. Held
Elec. Held
Mech. Held
A3 A3
1
— Y — Y
— Y Y Y Y Y Y Y — Y Y Y Y Y Y Y
3R,4,12 — Y — Y
On-Off push button (with holding circuit interlock)
Any
A12
Y — Y — Y
Y Y Y Y Y Y Y
Hand-Off-Auto selector switch . To substitute a key operated selector switch, use Form C33 and specify positions, legend marking, and key removal. This form must be used with another selector switch form (example: CC33). On-Off selector switch . To substitute a key operated selector switch, use Form C33 and specify positions, legend marking, and key removal. This form must be used with another selector switch form (example: C33C6).
Y Y [28]
Y Y [28]
C
1
— Y Y Y Y Y Y Y
C 3R,4,12 Y Y [28]
Y Y [28]
Y
Y Y Y Y Y Y Y
C6
1
Y
Y
Y
Y
— Y Y Y Y Y Y Y
3R, 4, 12 Y
C6
Y
Y
Y
Y
Y Y Y Y Y Y Y
Control circuit fuse (1 fuse) Control circuit fuses (2 fuses)
Any Any
F
Y Y
Y Y
Y Y
Y Y
Y Y
Y Y Y Y Y Y Y Y Y Y Y Y Y Y
F4
Control circuit transformer standard capacity 50/60 Hz Primary Fuses Secondary Fuses Transformer capacity 2 [29] 0 Std.
Y [30] Y [30] Y [30] Y [30] Y [30]
Y [31] Y [31] Y [31] Y [31] Y [31]
F4T 1, 4, 12
Y
Y
Y
Y
Y
Y Y Y Y Y
2
1
Std.
FF4T 1, 4, 12
Y
Y
Y
Y
Y
Y Y Y Y Y
Y [30] Y [30] Y [30]
2
1
100 VA Additional
FF4T11 1, 4, 12
Y
Y
Y
Y
Y
Y Y Y Y
Y [30] Y [30]
Y Y [30]
2
1
200 VA Additional
FF4T12 1, 4, 12
Y
Y
Y
Y
Y Y
Y [30]
Y [30]
2
1
300 VA Additional
FF4T13 1, 4, 12
Y
Y
Y
Y
Y
Y
Any
Noise reduced enclosure and shock mounted panel
G4
— Y — — — YYYYYYY
G10 1 [32] , 3R, 12 G101 1 [32] , 3R, 12
Addition of photoelectric receptacle
Y — Y — Y
Y Y Y Y Y Y Y
Addition of photoelectric receptacle with photo-cell Addition of photoelectric receptacle and relay (R6) [33]
Y — Y — Y
Y Y Y Y Y Y Y
G10R6 1 [32] , 12 — Y — Y G101R6 1 [32] , 12 — Y — Y
— Y Y Y Y Y Y Y — Y Y Y Y Y Y Y
With photo-cell installed [33]
Addition of terminal blocks (other than standard). The designation xx represents the number of terminals needed. Available in multiples of 5 only. Wired G56xx Any Y Y Y Y Y
Y Y Y Y Y Y Y Y Y Y Y Y Y Y
Any
Unwired
G50xx
Y Y Y Y
Y Y Y Y
Y Y Y Y
Y Y Y Y
Y
Addition of 24 hour time clock (120–277 V only)
1, 4, 12
K14
— Y Y Y Y Y Y Y — Y Y Y Y Y Y Y — Y Y Y Y Y Y Y
Addition of 24 hour time clock w/day omission (120–277 V) Addition of 7 day time clock (120–277 V) Addition of 24 hour time clock (120–277 V only) Addition of 24 hr time clock w/skip day (120–277 V)
K141 1, 4, 12 K142 1, 4, 12
K14
3R 3R 3R
— — — — Y — — — — Y — — — — Y
— Y Y Y Y — — — Y Y Y Y — — — Y Y Y Y — — Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
K141 K142
Addition of 7 day time clock (120–277 V) Addition of solid neutral terminal block
N 1, 4, 12
Y Y Y Y Y
Y Y Y Y Y
Y Y Y Y Y
Y Y Y Y Y
Std.
Red pilot light
Any Any Any Any Any Any Any Any Any Any Any Any
P1
Y Y Y Y
Two or more lights [34] (each) Red push-to-test pilot light
P
P21 [35]
Interlock necessary for pilot light one needed for each additional pilot light Two-wire interface for mechanically held [33] Addition of undervoltage and overvoltage relay Three wire control for long distance applications [33] Auxiliary contacts (specify number of N.O. + N.C.) Auxiliary electrical interlock installed on disconnect switch or circuit breaker operating mechanism
[36]
Y Y Y Y Y Y
R6
— Y — Y
— Y Y Y Y Y Y Y
R46 R62
Y
Y
Y
Y
Y
Y Y Y Y Y Y Y
— Y — Y
— Y Y Y Y Y Y Y
[36]
X
Y
Y
Y
Y Y Y Y Y
Y Y Y Y Y
Y Y Y Y Y Y
Y74
— — Y
— Y Y Y Y Y Y Y Y Y Y Y — — Y Y Y Y Y Y Y — — Y Y Y Y Y
Coil transient suppressor (120 Vac only)
Y145
Y Y Y
Y Y Y
Y Y Y
Addition of lightning arrestor
Y1532
Substitute copper only lugs for standard
Y157
[28] When ordering FormC on mechanically held devices, you must also include FormR6 . [29] Transformer voltage codes. [30] Single primary voltage must be specified using the codes shown in Table 16.207. [31] Mechanically held only. Electrically held device has a control circuit requiring a 120 V secondary, therefore, a transformer is supplied. The transformer comes wired to L1 and L2 unless FormS is called for. It is supplied with two primary and one secondary fuse. [32] Photocell mounted on a NEMA 1 enclosure is designed for indoor areas which rely on natural light. Addition of the photocell does not make the enclosure suitable for outdoor (NEMA Type 3R) installations. [33] Available for 24 V, 120 V, 240 V, 277 V and 480 V applications only. [34] For electrically held enclosed devices, the first pilot is wired in parallel with the coil. Operating interlocks are required for all additional pilot lights. Mechanically held devices require operating interlocks for all pilot lights. [35] Donot use Form X for any interlock wired in series with a pilot light, but do specify how the pilot light and interlock are to be wired into the circuit. [36] Electrically held 20 A multipole contactors cannot add interlocks. Additional poles can be used for the same function, however. Mechanically held (Type LX) provide one double throw auxiliary (or status) contact as standard.
16-80
© 2024 Schneider Electric All Rights Reserved
Made with FlippingBook Ebook Creator